Notifications
You must be signed in to change notification settings - Fork 11
ws_inp_times
Edgar Fuste edited this page Nov 2, 2021
·
1 revision
Defines various time step parameters used in the simulation.
Column name | Data type | Description | Example |
---|---|---|---|
id | integer | Id | |
duration | integer | Duration of the simulation | 24 |
hydraulic_timestep | character varying(10) | Determines how often a new hydraulic state of the network is computed | 0:30 |
quality_timestep | character varying(10) | Time step used to track changes in water quality throughout the network | 0:06 |
rule_timestep | character varying(10) | Time step used to check for changes in system status due to activation of rule-based controls between hydraulic time steps | 0:05 |
pattern_timestep | character varying(10) | Interval between time periods in all time patterns | 1:00 |
pattern_start | character varying(10) | Time offset at which all patterns will start | 0:00 |
report_timestep | character varying(10) | Time interval between which output results are reported | 1:00 |
report_start | character varying(10) | Length of time into the simulation at which output results begin to be reported. | 0:00 |
start_clocktime | character varying(10) | Time of day (e.g., 3:00 PM) at which the simulation begins | 12 |
statistic | character varying(18) | Determines what kind of statistical post-processing should be done on the time series of simulation results generated, defined on inp_typevalue as inp_value_times | NONE |