Description:

Defines various time step parameters used in the simulation.

Fields:

Column name Data type Description Example
id integer Id
duration integer Duration of the simulation 24
hydraulic_timestep character varying(10) Determines how often a new hydraulic state of the network is computed 0:30
quality_timestep character varying(10) Time step used to track changes in water quality throughout the network 0:06
rule_timestep character varying(10) Time step used to check for changes in system status due to activation of rule-based controls between hydraulic time steps 0:05
pattern_timestep character varying(10) Interval between time periods in all time patterns 1:00
pattern_start character varying(10) Time offset at which all patterns will start 0:00
report_timestep character varying(10) Time interval between which output results are reported 1:00
report_start character varying(10) Length of time into the simulation at which output results begin to be reported. 0:00
start_clocktime character varying(10) Time of day (e.g., 3:00 PM) at which the simulation begins 12
statistic character varying(18) Determines what kind of statistical post-processing should be done on the time series of simulation results generated, defined on inp_typevalue as inp_value_times NONE