Notifications
You must be signed in to change notification settings - Fork 11
ws_inp_pump_additional
Edgar Fuste edited this page Nov 2, 2021
·
1 revision
Defines additional pumps contained in the network, in case of installation with multiple pumps.
Column name | Data type | Description | Example |
---|---|---|---|
id | serial | Id | |
node_id | character varying(16) | Id of node | |
order_id | smallint | Order of pumps inside the instalation | |
power | character varying | Pump power | |
curve_id | character varying | Id of curve, defined on inp_curve | |
speed | numeric(12,6) | Pump speed | |
pattern | character varying | Id of pattern, defined on inp_pattern | |
status | character varying(12) | Status of pump, defined on inp_typevalue as inp_value_status_pump | CLOSED, OPEN |
energyparam | character varying(30) | Parameter of energy, defined on inp_typevalue as inp_value_param_energy | EFFIC, PATTERN, PRICE |
energyvalue | character varying(30) | Value of energy |