This page documents the status codes returned in the response footer. If you are looking for the machine state variable stat
go here instead: stat
The status code reports how a command was processed. It is the second number in the footer array for a response:
{"r":{"xjm":5000000000.000},"f":[3,0,6]}
Zero (0
, STAT_OK) means the command was processed. Anything else is an error. The following status codes are supported as of firmware build 100.xx. See error.h for the source:
// OS, communications and low-level status (must align with XIO_xxxx codes in xio.h)
#define STAT_OK 0 // function completed OK
#define STAT_ERROR 1 // generic error return (EPERM)
#define STAT_EAGAIN 2 // function would block here (call again)
#define STAT_NOOP 3 // function had no-operation
#define STAT_COMPLETE 4 // operation is complete
#define STAT_SHUTDOWN 5 // operation was shutdown (terminated gracefully)
#define STAT_PANIC 6 // system panic (not graceful)
#define STAT_EOL 7 // function returned end-of-line
#define STAT_EOF 8 // function returned end-of-file
#define STAT_FILE_NOT_OPEN 9
#define STAT_FILE_SIZE_EXCEEDED 10
#define STAT_NO_SUCH_DEVICE 11
#define STAT_BUFFER_EMPTY 12
#define STAT_BUFFER_FULL 13
#define STAT_BUFFER_FULL_FATAL 14
#define STAT_INITIALIZING 15 // initializing - not ready for use
#define STAT_ENTERING_BOOT_LOADER 16 // this code actually emitted from boot loader, not g2
#define STAT_FUNCTION_IS_STUBBED 17
#define STAT_ALARM 18 // system alarm triggered
#define STAT_NO_DISPLAY 19 // suppress results display - presumably handled upstream
// Internal errors and startup messages
#define STAT_INTERNAL_ERROR 20 // unrecoverable internal error
#define STAT_INTERNAL_RANGE_ERROR 21 // number range other than by user input
#define STAT_FLOATING_POINT_ERROR 22 // number conversion error
#define STAT_DIVIDE_BY_ZERO 23
#define STAT_INVALID_ADDRESS 24
#define STAT_READ_ONLY_ADDRESS 25
#define STAT_INIT_FAILURE 26
#define STAT_ERROR_27 27 // was ALARMED in 0.97
#define STAT_FAILED_TO_GET_PLANNER_BUFFER 28
#define STAT_GENERIC_EXCEPTION_REPORT 29 // used for test
#define STAT_PREP_LINE_MOVE_TIME_IS_INFINITE 30
#define STAT_PREP_LINE_MOVE_TIME_IS_NAN 31
#define STAT_FLOAT_IS_INFINITE 32
#define STAT_FLOAT_IS_NAN 33
#define STAT_PERSISTENCE_ERROR 34
#define STAT_BAD_STATUS_REPORT_SETTING 35
#define STAT_FAILED_GET_PLANNER_BUFFER 36
// Assertion failures - build down from 99 until they meet the system internal errors
#define STAT_BUFFER_FREE_ASSERTION_FAILURE 88
#define STAT_STATE_MANAGEMENT_ASSERTION_FAILURE 89
#define STAT_CONFIG_ASSERTION_FAILURE 90
#define STAT_XIO_ASSERTION_FAILURE 91
#define STAT_ENCODER_ASSERTION_FAILURE 92
#define STAT_STEPPER_ASSERTION_FAILURE 93
#define STAT_PLANNER_ASSERTION_FAILURE 94
#define STAT_CANONICAL_MACHINE_ASSERTION_FAILURE 95
#define STAT_CONTROLLER_ASSERTION_FAILURE 96
#define STAT_STACK_OVERFLOW 97
#define STAT_MEMORY_FAULT 98 // generic memory corruption detected by magic numbers
#define STAT_GENERIC_ASSERTION_FAILURE 99 // generic assertion failure - unclassified
// Application and data input errors
// Generic data input errors
#define STAT_UNRECOGNIZED_NAME 100 // parser didn't recognize the name
#define STAT_INVALID_OR_MALFORMED_COMMAND 101 // malformed line to parser
#define STAT_BAD_NUMBER_FORMAT 102 // number format error
#define STAT_UNSUPPORTED_TYPE 103 // an otherwise valid JSON type is not supported
#define STAT_PARAMETER_IS_READ_ONLY 104 // input error: parameter cannot be set
#define STAT_PARAMETER_CANNOT_BE_READ 105 // input error: parameter cannot be returned
#define STAT_COMMAND_NOT_ACCEPTED 106 // input error: command cannot be accepted at this time
#define STAT_INPUT_EXCEEDS_MAX_LENGTH 107 // input error: input string is too long
#define STAT_INPUT_LESS_THAN_MIN_VALUE 108 // input error: value is under minimum
#define STAT_INPUT_EXCEEDS_MAX_VALUE 109 // input error: value is over maximum
#define STAT_INPUT_VALUE_RANGE_ERROR 110 // input error: value is out-of-range
#define STAT_JSON_SYNTAX_ERROR 111 // JSON input string is not well formed
#define STAT_JSON_TOO_MANY_PAIRS 112 // JSON input string has too many JSON pairs
#define STAT_JSON_OUTPUT_TOO_LONG 113 // JSON output exceeds buffer size
#define STAT_NESTED_TXT_CONTAINER 114 // JSON 'txt' fields cannot be nested
#define STAT_MAX_DEPTH_EXCEEDED 115 // JSON exceeded maximum nesting depth
#define STAT_VALUE_TYPE_ERROR 116 // JSON value does not agree with variable type
// Gcode errors and warnings (Most originate from NIST - by concept, not number)
#define STAT_GCODE_GENERIC_INPUT_ERROR 130 // generic error for gcode input
#define STAT_GCODE_COMMAND_UNSUPPORTED 131 // G command is not supported
#define STAT_MCODE_COMMAND_UNSUPPORTED 132 // M command is not supported
#define STAT_GCODE_MODAL_GROUP_VIOLATION 133 // gcode modal group error
#define STAT_GCODE_AXIS_IS_MISSING 134 // command requires at least one axis present
#define STAT_GCODE_AXIS_CANNOT_BE_PRESENT 135 // error if G80 has axis words
#define STAT_GCODE_AXIS_IS_INVALID 136 // an axis is specified that is illegal for the command
#define STAT_GCODE_AXIS_IS_NOT_CONFIGURED 137 // WARNING: attempt to program an axis that is disabled
#define STAT_GCODE_AXIS_NUMBER_IS_MISSING 138 // axis word is missing its value
#define STAT_GCODE_AXIS_NUMBER_IS_INVALID 139 // axis word value is illegal
#define STAT_GCODE_ACTIVE_PLANE_IS_MISSING 140 // active plane is not programmed
#define STAT_GCODE_ACTIVE_PLANE_IS_INVALID 141 // active plane selected is not valid for this command
#define STAT_GCODE_FEEDRATE_NOT_SPECIFIED 142 // move has no feedrate
#define STAT_GCODE_INVERSE_TIME_MODE_CANNOT_BE_USED 143 // G38.2 and some canned cycles cannot accept inverse time mode
#define STAT_GCODE_ROTARY_AXIS_CANNOT_BE_USED 144 // G38.2 and some other commands cannot have rotary axes
#define STAT_GCODE_G53_WITHOUT_G0_OR_G1 145 // G0 or G1 must be active for G53
#define STAT_REQUESTED_VELOCITY_EXCEEDS_LIMITS 146
#define STAT_CUTTER_COMPENSATION_CANNOT_BE_ENABLED 147
#define STAT_PROGRAMMED_POINT_SAME_AS_CURRENT_POINT 148
#define STAT_SPINDLE_SPEED_BELOW_MINIMUM 149
#define STAT_SPINDLE_SPEED_MAX_EXCEEDED 150
#define STAT_SPINDLE_MUST_BE_OFF 151
#define STAT_SPINDLE_MUST_BE_TURNING 152 // some canned cycles require spindle to be turning when called
#define STAT_ARC_ERROR_RESERVED 153 // RESERVED
#define STAT_ARC_HAS_IMPOSSIBLE_CENTER_POINT 154 // trap (.05 inch/.5 mm) OR ((.0005 inch/.005mm) AND .1% of radius condition
#define STAT_ARC_SPECIFICATION_ERROR 155 // generic arc specification error
#define STAT_ARC_AXIS_MISSING_FOR_SELECTED_PLANE 156 // arc is missing axis (axes) required by selected plane
#define STAT_ARC_OFFSETS_MISSING_FOR_SELECTED_PLANE 157 // one or both offsets are not specified
#define STAT_ARC_RADIUS_OUT_OF_TOLERANCE 158 // WARNING - radius arc is too large - accuracy in question
#define STAT_ARC_ENDPOINT_IS_STARTING_POINT 159
#define STAT_P_WORD_IS_MISSING 160 // P must be present for dwells and other functions
#define STAT_P_WORD_IS_INVALID 161 // generic P value error
#define STAT_P_WORD_IS_ZERO 162
#define STAT_P_WORD_IS_NEGATIVE 163 // dwells require positive P values
#define STAT_P_WORD_IS_NOT_AN_INTEGER 164 // G10s and other commands require integer P numbers
#define STAT_P_WORD_IS_NOT_VALID_TOOL_NUMBER 165
#define STAT_D_WORD_IS_MISSING 166
#define STAT_D_WORD_IS_INVALID 167
#define STAT_E_WORD_IS_MISSING 168
#define STAT_E_WORD_IS_INVALID 169
#define STAT_H_WORD_IS_MISSING 170
#define STAT_H_WORD_IS_INVALID 171
#define STAT_L_WORD_IS_MISSING 172
#define STAT_L_WORD_IS_INVALID 173
#define STAT_Q_WORD_IS_MISSING 174
#define STAT_Q_WORD_IS_INVALID 175
#define STAT_R_WORD_IS_MISSING 176
#define STAT_R_WORD_IS_INVALID 177
#define STAT_S_WORD_IS_MISSING 178
#define STAT_S_WORD_IS_INVALID 179
#define STAT_T_WORD_IS_MISSING 180
#define STAT_T_WORD_IS_INVALID 181
// g2core errors and warnings
#define STAT_GENERIC_ERROR 200
#define STAT_MINIMUM_LENGTH_MOVE 201 // move is less than minimum length
#define STAT_MINIMUM_TIME_MOVE 202 // move is less than minimum time
#define STAT_LIMIT_SWITCH_HIT 203 // a limit switch was hit causing shutdown
#define STAT_COMMAND_REJECTED_BY_ALARM 204 // command was not processed because machine is alarmed
#define STAT_COMMAND_REJECTED_BY_SHUTDOWN 205 // command was not processed because machine is shutdown
#define STAT_COMMAND_REJECTED_BY_PANIC 206 // command was not processed because machine is paniced
#define STAT_KILL_JOB 207 // ^d received (job kill)
#define STAT_NO_GPIO 208 // no GPIO exists for this value
#define STAT_TEMPERATURE_CONTROL_ERROR 209 // temperature controls err'd out
#define STAT_SOFT_LIMIT_EXCEEDED 220 // soft limit error - axis unspecified
#define STAT_SOFT_LIMIT_EXCEEDED_XMIN 221 // soft limit error - X minimum
#define STAT_SOFT_LIMIT_EXCEEDED_XMAX 222 // soft limit error - X maximum
#define STAT_SOFT_LIMIT_EXCEEDED_YMIN 223 // soft limit error - Y minimum
#define STAT_SOFT_LIMIT_EXCEEDED_YMAX 224 // soft limit error - Y maximum
#define STAT_SOFT_LIMIT_EXCEEDED_ZMIN 225 // soft limit error - Z minimum
#define STAT_SOFT_LIMIT_EXCEEDED_ZMAX 226 // soft limit error - Z maximum
#define STAT_SOFT_LIMIT_EXCEEDED_AMIN 227 // soft limit error - A minimum
#define STAT_SOFT_LIMIT_EXCEEDED_AMAX 228 // soft limit error - A maximum
#define STAT_SOFT_LIMIT_EXCEEDED_BMIN 229 // soft limit error - B minimum
#define STAT_SOFT_LIMIT_EXCEEDED_BMAX 220 // soft limit error - B maximum
#define STAT_SOFT_LIMIT_EXCEEDED_CMIN 231 // soft limit error - C minimum
#define STAT_SOFT_LIMIT_EXCEEDED_CMAX 232 // soft limit error - C maximum
#define STAT_SOFT_LIMIT_EXCEEDED_ARC 233 // soft limit err on arc
#define STAT_HOMING_CYCLE_FAILED 240 // homing cycle did not complete
#define STAT_HOMING_ERROR_BAD_OR_NO_AXIS 241
#define STAT_HOMING_ERROR_ZERO_SEARCH_VELOCITY 242
#define STAT_HOMING_ERROR_ZERO_LATCH_VELOCITY 243
#define STAT_HOMING_ERROR_TRAVEL_MIN_MAX_IDENTICAL 244
#define STAT_HOMING_ERROR_NEGATIVE_LATCH_BACKOFF 245
#define STAT_HOMING_ERROR_HOMING_INPUT_MISCONFIGURED 246
#define STAT_HOMING_ERROR_MUST_CLEAR_SWITCHES_BEFORE_HOMING 247
#define STAT_ERROR_248 248
#define STAT_ERROR_249 249
#define STAT_PROBE_CYCLE_FAILED 250 // probing cycle did not complete
#define STAT_PROBE_TRAVEL_TOO_SMALL 251
#define STAT_NO_PROBE_SWITCH_CONFIGURED 252
#define STAT_MULTIPLE_PROBE_SWITCHES_CONFIGURED 253
#define STAT_PROBE_SWITCH_ON_ABC_AXIS 254
#define STAT_ERROR_255 255
Getting Started Pages
- Home
- What is g2core?
- Who uses g2core?
- Jerk-Controlled Motion
- Getting Started with g2core
- Connecting to g2core
- Configuring g2core
- Flashing g2core
- Troubleshooting
Reference Pages
- Gcodes
- Mcodes
- Text Mode
- JSON Communications
- GPIO Digital IO
- Alarms & Exceptions
- Power Management
- Coordinate Systems
- Status Reports
- Status Codes
- G2 Communications
- Tool Offsets and Selection
- Probing
- Feedhold, Resume, Job Kill
- Marlin Compatibility
- 9 Axis UVW Operation
- gQuintic Specs
Discussion Topics
- Roadmap
- GPIO for 1.X Releases
- Toolheads
- Raster Streaming Prototol
- g2core REST Interface
- Gcode Parsing
- G2 3DP Dialect
- Consensus Gcode
- Digital DRO
- Overview of Motion Processing
Developer Pages
- Development & Contribution
- Branching and Release - DRAFT
- Getting Started with g2core Development
- Project Structure & Motate
- Compiling G2
- OSX w/Xcode
- OSX/Linux Command Line
- Windows10 w/AtmelStudio7
- Debugging G2 on OSX
- Board and Machine Profiles
- Arduino Due Pinout
- Arduino DUE External Interfaces
- Diagnostics
- Debugging w/Motate Pins
- Development Troubleshooting
- g2core Communications
- Git Procedures
- Windows 10 / VMware 8 Issues
- Dual Endpoint USB Internals
- G2core License
- VSCode Setup
- Compatibility Axioms
- Wiki History