Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Added support of SEN-14001 (9DoF Razor IMU M0) #34

Merged
merged 1 commit into from
Jan 20, 2018
Merged

Added support of SEN-14001 (9DoF Razor IMU M0) #34

merged 1 commit into from
Jan 20, 2018

Conversation

lebarsfa
Copy link
Member

@lebarsfa lebarsfa commented Dec 20, 2017

Resolves #28. The firmware modifications to support the M0 were originally made from the latest version of https://github.com/Razor-AHRS/razor-9dof-ahrs, forked in https://github.com/lebarsfa/razor-9dof-ahrs. Then, the ROS-specific modifications from https://github.com/KristofRobot/razor_imu_9dof were added to add ROS compatibility. Finally, following a suggestion on https://answers.ros.org/question/261398/sparkfun-9dof-razor-imu-sen-14001/, this pull request is proposed, and a pull request to https://github.com/Razor-AHRS/razor-9dof-ahrs will be proposed soon...

@fabolhak
Copy link

Hello,
thank you for this contribution. It really helped us a lot using the SEN-14001 in our project :). I just have one question: There is this accel_factor which is in the Arduino code 250 and in the ROS code 256.

Is this on purpose or a mistake? I get better results when using 256 in the Arduino code as well.

@lebarsfa
Copy link
Member Author

Glad to know that it helped!

For the coefficient, it was on purpose, but that does not prevent it to be a mistake...

From what I understand of the different pieces of code, the 256 in ROS code is needed due to the #define GRAVITY 256.0f in Razor_AHRS.ino and the 250 added in Sensors.ino is supposed to compensate the 250 in Razor_AHRS.ino used for default calibration values.

Here is what should happen :

  • imu.calcAccel(imu.ax) in Sensors.ino is supposed to give accelerations in g's. Let's assume that it is equal to -1 as an example.
  • Therefore, accel[0] = -250.0f*imu.calcAccel(imu.ax) should be 250.
  • Then, we have float ACCEL_X_OFFSET = ((ACCEL_X_MIN + ACCEL_X_MAX) / 2.0f) equals to 0 and float ACCEL_X_SCALE = (GRAVITY / (ACCEL_X_MAX - ACCEL_X_OFFSET)) equals to 256/250 in Razor_AHRS.ino.
  • In Razor_AHRS.ino, the calibration code accel[0] = (accel[0] - ACCEL_X_OFFSET) * ACCEL_X_SCALE gives 256.
  • Later, ROS code should get somehow the value of accel[0] as float(words[3]) in imuMsg.linear_acceleration.x = -float(words[3]) * accel_factor, so accel_factor = 9.806 / 256.0 makes imuMsg.linear_acceleration.x equal to -9.806.

If this is correct, I would say that your better results with 256 could be probably obtained equivalently without modifying the code, by modifying your accelerometers calibration values ACCEL_X_MIN, ACCEL_X_MAX, etc.

Let me know if there is something wrong...

@fabolhak
Copy link

Hello,
thank you for the quick reply and the detailed explanation. At first I was skeptical, because of the hardcoded default calibration parameter 250. But I also did the calculation with different values and the mathematics seem to be correct.

So probably my calibration wasn't the best.

Thank you again :)

@KristofRobot
Copy link
Collaborator

@lebarsfa - I am merging this, although I have no way to test this myself. However, I am relying on the testing of @tyzaizl and @fabolhak

Thank you for your contribution!

@KristofRobot KristofRobot merged commit d11c60b into ENSTABretagneRobotics:indigo-devel Jan 20, 2018
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment