Skip to content

Interaction between Android systems and PLUX devices is extremely easy, using the available Unity/Android API. This repository contains a demonstration of this type of integration through an intuitive Sample APP.

License

Notifications You must be signed in to change notification settings

pluxbiosignals/unity-android-sample

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

11 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

PLUX Android/Unity API | Sample APP

The Sample APP contained inside this repository provides a practical and intuitive resource to explore the integration of some signal acquisition devices commercialized by PLUX (biosignalsplux, biosignalsplux Solo, muscleBAN and cardioBAN) in an Android application created through Unity environment.

Some questions can be enlightened, such as:

  • How PLUX acquisition systems can be searched and found on the Android device?
  • How to pair an Android tablet/mobile phone with a PLUX device?
  • How to start a real-time acquisition?
  • How to stop the real-time acquisition?

Recommended SDK and Unity Editor

  • SDK Platform 27 [Android 8.1]
  • Unity 2022.1.16f1

Limitations

  • PLUX devices from BITalino product line are not currently supported.
  • Graphical User Interface is optimized for tablets.

How to Use It

The provided project folder is a ready to use Unity solution, you simply need to access the cloned folder through Unity interface.

On the following animation we can quickly show the main functionalities of our Sample APP:

sample-app-animation.gif

How to Easily Integrate the API in your Unity Project?

  1. Inside the Plugins folder of our Sample APP, copy the Android/hw-api.dll file to the Plugins folder of your Unity project. This .dll contains the PLUX API Plugin, acting as an interface between your application and PLUX hardware
  2. Copy Scripts/Utils folder to the Scripts directory of you Unity project. Classes contained inside this folder will be responsible for a high-level abstraction in the interaction between your C# scripts and PLUX API Plugin

After the previous two steps, you will be fully prepared to expand your Unity project and include some interesting functionalities through the use of PLUX signal acquisition devices.

In order to trigger the execution of a specific operation, such as a) PLUX Devices Scan, b) Android/PLUX Device Connection, c) Start/Stop of a Real-Time Acquisition or d) Android/PLUX Device Disconnection, it will only be necessary to call one of the available methods of the DeviceController class (Methods).

Android/Unity API

Methods


Scan

Method that is used to trigger the start of a Bluetooth device scan, searching for PLUX data acquisition systems. This method is invoked when the "Scan" button of the Sample APP is pressed.

public void Scan(bool enable)

Description

The input argument defines if the scanning process will be executed with a timeout limit, i.e., if enable is true then the search for Bluetooth devices will be conducted during 10 seconds.

Otherwise, if this parameter is false, a previously started scan can be securely interrupted/stopped.

Parameters

  • enable bool: A flag that defines if the scan should be started (true) or stopped (false) before the standard 10 seconds period ends.

Connect

This method is intended to establish a Bluetooth connection with a PLUX device identifiable through the respective MAC-Address.

public void Connect(string id)

Description

With Connect method it is possible to establish a Bluetooth connection between an Android system and a PLUX Device. To ensure a successful pairing, the user only needs to specify the device mac-address (attached to biosignalsplux, biosignalsplux Solo or MuscleBAN hub...). This mac-address should be inserted in a string format with the following structure: "00:07:80:4D:2E:AD" (6 pairs of characters separated by ":").

Parameters

  • id string: The mac-address of the PLUX device with which a Bluetooth connection will be established.

Disconnect

Opposing to Connect, this method is very useful when you want to safely cut the connection between PLUX devices and an Android system.

public void Disconnect(string id)

Description

Through Disconnect method the established connection between a PLUX device and an Android system can be securely closed. If a real-time acquisition is yet being executed, a stop command is automatically sent, ensuring the end of communication loop.

Parameters

  • id string: The mac-address of the PLUX device whose connection will be broken.

StartAcquisition

Class method used to start a Real-Time acquisition at the PLUX device paired with the Android system through Connect method.

public void StartAcquisition(String id, int frequency, int nChannels, int freqDivisor)

Description

In order to communicate with a digital system (as an Android tablet or mobile phone) the PLUX device needs to execute an Analogical to Digital Conversion (ADC), through data sampling. Taking ADC stage into consideration, while starting a real-time acquisition, selecting a specific sampling rate or downsampling ratio is extremely easy through the inputs of StartAcquisition.

Parameters

  • id string: mac-address of a previously connected PLUX device, where the real-time acquisition should take place.
  • frequency int: Desired sampling rate that will be used during the data acquisition stage. The used units are in Hz (samples/s).
  • numberOfChannels int: Number of the active channels that will be used during data acquisition. With biosignalsplux it is possible to collect data from up to 8 channels (simultaneously).
  • freqDivisor int: Frequency divisor, i.e., acquired data will be subsampled accordingly to this parameter. If freqDivisor = 10, it means that each set of 10 acquired samples will trigger the communication of a single sample (through the communication loop).

Stop

Class method used to interrupt the real-time communication loop triggered by StartAcquisition() method.

public void Stop(String id)

Description

After starting a real-time acquisition a communication loop between the PLUX device and the Android system starts running on a parallel thread. With Stop function, first of all, the communication loop is interrupted, stopping securely the real-time acquisition.

Parameters

  • id string: mac-address of a PLUX device where a real-time data acquisition is currently taking place.

IsSensorConnected

A simple getter method that retrieves the state of an internal flag intended to identify when a connection between a PLUX device and an Android system is currently active or not.

public bool IsSensorConnected()

Description

This method is extremely useful to control the start of a real-time acquisition in a secure way, i.e., it is advisable to verify if a Bluetooth connection is active before triggering the start of a real-time data acquisition.

Parameters

Method without input parameters

Returned Parameters

A Boolean flag is returned, stating that a Bluetooth connection between a PLUX device and an Android system is currently active (true) or inactive (false).


Close

A quick but very reliable way to destroy in a securely the DeviceController instance.

public void Close()

Description

This method acts as a destroyer of a DeviceController instance unregistering the BroadcastReceivers used by PLUX API Plugin in the Android environment.

Parameters

Method without input parameters


Quick-Notes

There are some relevant callbacks that should be taken into consideration for a solid and secure implementation of all API functionalities.

The following instructions must be included in the Start() and OnDisable() callbacks of Unity APPs:

void Start () {
    // Link the callbacks to the DeviceController object.
    DeviceController.OnDataEvent += OnNewDataEvent;  
    DeviceController.OnDeviceConnectionChange += OnDeviceConnection;  
    DeviceController.OnNewDeviceFound += OnNewDeviceFound;
}

void OnDisable(){
    // Remove callbacks from the scope of DeviceController class.
    DeviceController.OnDataEvent -= OnNewDataEvent;  
    DeviceController.OnDeviceConnectionChange -= OnDeviceConnection; 
    DeviceController.OnNewDeviceFound -= OnNewDeviceFound; 

    // Destroy the DeviceController instance.
    DeviceController.Instance.Close();
}

A practical example of application of each callback (a) OnNewDataEvent | b) OnDeviceConnection | c) OnNewDeviceSelected) is available on the Scripts/MainScreenManager.cs file of the Sample APP.

OnNewDataEvent is used to receive the data packages communicated by the PLUX device, while OnNewDeviceFound is useful to receive the mac-address of each device detected during the Bluetooth scan.

Regarding OnDeviceConnection, this callback is a powerful resource to understand if the PLUX device is connected/disconnected or if a real-time acquisition is under execution.