In this release you have for Souliss side:
n°1 Typical 31 : Temperature control with cooling and heating mode, on slot 0
n°1 Typical 52 : Temperature measure (-20, +50) °C, on slot 5
n°1 Typical 53 : Humidity measure (0, 100) %, on slot 7
n°1 Typical 19 : Single Color LED Strip, used for backlight dimming, on slot 9
n°1 Typical 11 : ON/OFF Digital Output,used only on software side for AWAY function, on slot 11

for functionality side you have:
-n°2 layout, you can select it by menù
-NTP clock, you can adjust your UTC by menù
-CRONO function, you can select between 4 diffrent setpoint(adjustable by menù),for every 1/2hour,for every day
-Copy/Paste function of day selected, in other day/days
-Save all data, crono & preferences in eeprom/flash(first boot,data will be taken from preferences.h)