#libsml-testing
this is a try to collect SML messages from real-world Smart Meters
The Open-Source Smart-Metering community would like to get some realworld data
from all those SML Smart Meters out there, so please submit some data from
your SML capable device.
This is very valuable information to test SML parsers, to know about the
capabilities of different Smart Meters and to get an impression on how good
Smart Meters behave according to the specs.
Create dumps in binary and hex format from your smartmeter and submit those as
follows:
1. Do proper initialization of the serial interface via stty, vzlogger,
<your_favourite_metering_tool> (serial interface should remain initialized
after terminating vzlogger etc)
2. Dump binary data to a file like this:
dd if=/dev/ttyUSB0 of=yoursmldump.bin bs=1 count=4096 iflag=fullblock
3. Convert your .bin file into .hex like this:
cat yoursmldump.bin |hexdump -ve '1/1 "%.2X"' >yoursmldump.hex
4. Name your files like this: <VENDOR>_<MODEL>-<MODELNR>.bin|hex, e.g.
EMH_eHZ-HW8E2AWL0EK2P.bin and EMH_eHZ-HW8E2AWL0EK2P.hex
5. If you like, add some owner/contact information, so others may contact you
about your smart meter and ask questions (see FILES)
6. As we have no better method for now, Zip your files and submit them via mail
to devzero AT web.de . You can also send a git pull request.
7. Discuss about with others about SML on [email protected].
8. For testing you can use the libsml parser example program from
https://github.com/volkszaehler/libsml
Use it like this for example:
$ cat ../../libsml-testing/EMH_eHZ-GW8E2A500AK2.bin | ./sml_server - | head -n10
129-129:199.130.3*255#EMH#
1-0:0.0.0*255#02280816#
1-0:1.8.1*255#14798112.9#Wh
1-0:1.8.2*255#2012.4#Wh
0-0:96.1.255*255#0002280816#
1-0:1.7.0*255#13.8#W
129-129:199.130.3*255#EMH#
1-0:0.0.0*255#02280816#
1-0:1.8.1*255#14798113.0#Wh
1-0:1.8.2*255#2012.4#Wh
9. Do NOT use libsml from dailab github repo, as this is unmaintained.
https://github.com/volkszaehler/libsml
is the official version
10. If your sml program which should process binary sml does not support stdin, you can
feed binary sml via a serial fake device the following way. use that instead of
/dev/ttyUSB0 or /dev/ttyS0
Effectively, you simulate a serially attached smart meter this way
get socat and execute
# socat -d -d pty,raw,echo=0 pty,raw,echo=0
socat will connect two pty's and output should look like this:
# socat -d -d pty,raw,echo=0 pty,raw,echo=0
2018/01/20 22:08:48 socat[8029] N PTY is /dev/pts/6
2018/01/20 22:08:48 socat[8029] N PTY is /dev/pts/9
2018/01/20 22:08:48 socat[8029] N starting data transfer loop with FDs [5,5] and [7,7]
connect your favourite SML parser/tool to one of the pty's socat did attach to:
# ./sml_server /dev/pts/6
now feed a binary sml dump to the other pty's:
# cat EMH_eHZ-GW8E2A500AK2.bin >/dev/pts/9
you can throttle the data rate with "pv" (pipe viewer) to simulate serial line slowness:
# cat EMH_eHZ-GW8E2A500AK2.bin | pv -L 9600 >/dev/pts/9
now watch output from your favourite SML parser/tool or troubleshoot/debug...
forked from devZer0/libsml-testing
-
Notifications
You must be signed in to change notification settings - Fork 0
magicWF/libsml-testing
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
About
collection of SML messages/telegrams from Smart Meters
Resources
Stars
Watchers
Forks
Releases
No releases published
Packages 0
No packages published