40 changes: 19 additions & 21 deletions sections/serialRemnants.rst
Original file line number Diff line number Diff line change
Expand Up @@ -39,12 +39,10 @@ the serial register during the clear, to avoid the construction of
pockets at this image-serial register interface.

.. image:: /figures/plots_R12_S20_C15_E1880_bias_2024103000303.png
:target: .. /figures/plots_R12_S20_C15_E1880_bias_2024103000303.png
:alt: Figure showing the impact of the various type of clear on a bias taken after a saturated flat for an E2V sensor

In this images , we can see for 3 type of sequencer ( from left to right : V29 , NoP and NopSF), a zoom on the first lines of an e2v amplifier ( here R12_S20 C10) shown as a 2D image ( top plots) or with the mean signal per line (bottom plots). A bias taken just after a saturated flat in a e2v
CCD will show a residual signal in the first lines when using the default clear (left images,clear=v29 ) : the first line has an almost saturated signal ( ~ 100 kADU here), and a significant signal is seen up to the line ~50 here. In practice, in function of the amplifier, signal can be seen up
to line 20-50. When using the NoP clear (central plots), we can already see a strong reduction of the unclear charges still present in the first acquired bias after a saturated flat. The NoPSF clear fully clear the saturated flat , and no uncleared charges are observed in the following bias.
:target: ../figures/plots_R12_S20_C15_E1880_bias_2024103000303.png
:alt: Figure showing the impact of the various type of clear on a bias taken after a saturated flat for an E2V sensor. We present for 3 types of sequencer ( from left to right : V29 , NoP and NopSF), a zoom on the first lines of an e2v amplifier ( here R12_S20 C10) shown as a 2D image ( top
plots) and presented as the mean signal per line (bottom plots). A bias taken just after a saturated flat in a e2v CCD will show a residual signal in the first lines when using the default clear (left images,clear=v29 ) : the first line has an almost saturated signal ( ~ 100 kADU here),
and a significant signal is seen up to the line ~50 here. In practice, in function of the amplifier, signal can be seen up to line 20-50. When using the NoP clear (central plots), we can already see a strong reduction of the unclear charges still present in the first acquired bias after a saturated flat. The NoPSF clear fully clear the saturated flat , and no uncleared charges are observed in the following bias.



Expand All @@ -54,25 +52,25 @@ pockets at this image-serial register interface.
.. table:: This table summaries the different clear methods used so
far . .

+------------------------+------------+----------+-------------+----------------+-----------------+-------------------------+--------+-------+
+------------------------+------------+----------+-------------+----------------+-----------------+-------------------------+--------+-------+
| | Default Clear | Multi Clear | Multi Clear | Deep Clear | No Pocket (NoP) | No Pocket Serial Flush (NoPSF) | Header 3 | Header 4 |
| | 1 Clear | 3 Clears | 5 Clears | Clear +1 Line | 1 Clear | 1 Clear | | |
| | (seq. V29 ) | (seq. V29 ) | (seq. V29 ) | (Seq. V23 DC) | (seq. V29_NoP) | ( seq. V29, V30 ) | | |
+===================+==========+==========+========+=============+==============+====================+======+======+
| Clear duration | 65.5 ms | 196.5 ms | 327.4 ms | 64.69 ms | 65.8 ms | 67 ms | | |
+===================+==========+==========+==========+==========+================+===================+======+=======+
| "E2V" after saturated Flat | | | | | | | | |
+------------------------+------------ + | +----------------+-------------+-------------------+-------+---------+
| R30_S10_C10 E2V | | | | | | | | |
| Bright Column (~ sat. Star) | | No residual e- | No residual e- | | | | | |
+===================+========== | +==========+===========+==========+==========+==========+
| "ITL" after saturated Flat | | in following | in following | | | | | |
+------------------------+------------+ | +----------------+-------------+-------------------+-------+---------+
| R02_S20_C14 ITL | | image | image | | | | | |
|Bright Column (~ sat. Star) | | | | | | | | |
+===================+==========+==========+==========+==========+===========+==========+==========+==========+
| R01_S10 ITL "unique" | | | | | | | | |
+------------------------+------------+------------+----------+----------------+-------------+-------------------+-------+---------+
| Clear duration | 65.5 ms | 196.5 ms | 327.4 ms | 64.69 ms | 65.8 ms | 67 ms | | |
+------------------------+------------+------------+----------+----------------+-------------+----------------------------------+-------+---------+
| "E2V" after saturated Flat | | | | | | | | |
+------------------------+------------ + | +----------------+-------------+----------------------------+-------+---------+
| R30_S10_C10 E2V | | | | | | | | |
| Bright Column (~ sat. Star) | | No residual e- | No residual e- | | | | | |
+------------------------+------------+ + +----------------+-------------+----------------------------------+-------+---------+
| "ITL" after saturated Flat | | in following | in following | | | | | |
+------------------------+------------+ + +----------------+-------------+-----------------------------+-------+---------+
| R02_S20_C14 ITL | | image | image | | | | | |
|Bright Column (~ sat. Star) | | | | | | | | |
+------------------------+------------+------------+----------+----------------+-------------+----------------------------------+-------+---------+
| R01_S10 ITL "unique" | | | | | | | | |
+------------------------+------------+------------+----------+----------------+-------------+----------------------------------+-------+---------+