2 changes: 1 addition & 1 deletion IBPSA/Fluid/FMI/UsersGuide.mo
Original file line number Diff line number Diff line change
Expand Up @@ -249,7 +249,7 @@ The model
<a href=\"modelica://IBPSA.Fluid.Movers.FlowControlled_m_flow\">
IBPSA.Fluid.Movers.FlowControlled_m_flow</a>
cannot be exported as an FMU.
This is because it assignes the mass flow rate.
This is because it assigns the mass flow rate.
However, the input connector
<a href=\"modelica://IBPSA.Fluid.FMI.Interfaces.Inlet\">
IBPSA.Fluid.FMI.Interfaces.Inlet</a>
Expand Down
6 changes: 4 additions & 2 deletions IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo
Original file line number Diff line number Diff line change
Expand Up @@ -422,7 +422,8 @@ Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning.",
"*** Warning in " + getInstanceName() +
": Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber.
This requires per.pressure to be provided.
Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided.",
Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided.
Also consider using models under Movers.Preconfigured which autopopulate a pressure curve.",
level=AssertionLevel.warning);

assert(per.havePressureCurve or per.haveWMot_nominal or
Expand All @@ -433,7 +434,8 @@ Because it is not, the model overrides this setting by using per.etaHydMet=.NotP
"*** Warning in " + getInstanceName() +
": Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve.
This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided,
the model overrides this setting and by using per.etaMotMet=.NotProvided.",
the model overrides this setting and by using per.etaMotMet=.NotProvided.
Also consider using models under Movers.Preconfigured which autopopulate a pressure curve.",
level=AssertionLevel.warning);

assert(per.powerOrEfficiencyIsHydraulic or
Expand Down
Original file line number Diff line number Diff line change
@@ -1,24 +1,18 @@
simulateModel("IBPSA.Fluid.HeatExchangers.Validation.HeaterCooler_u", method="CVode", tolerance=1e-6, stopTime=1200, resultFile="HeaterCooler_u");
createPlot(id = 1,
position = {78, 39, 400, 444},
y = {"con1.u_s", "con1.u_m", "con2.u_m"},
range = {0.0, 1200.0, 35.0, 15.0},
autoscale = true,
autoerase = true,
autoreplot = true,
grid = true,
color = true,
leftTitleType = 1,
bottomTitleType = 1);
createPlot(id = 20,
position = {78, 39, 400, 219},
y = {"con1.y", "con2.y"},
range = {0.0, 1200.0, 1.5, -0.5},
autoscale = true,
autoerase = true,
autoreplot = true,
grid = true,
color = true,
subPlot = 2,
leftTitleType = 1,
bottomTitleType = 1);
createPlot(id=1,
position={125, 65, 400, 447},
y={"con1.u_s", "con1.u_m", "con2.u_m"},
range={0.0, 1200.0, 290.0, 305.0},
grid=true,
subPlot=101,
colors={{28,108,200}, {238,46,47}, {0,140,72}},
timeUnit="s");
createPlot(id=1,
position={125, 65, 400, 447},
y={"con1.y", "con2.y"},
range={0.0, 1200.0, -0.5, 1.5},
grid=true,
subPlot=102,
colors={{28,108,200}, {238,46,47}},
timeUnit="s");

Original file line number Diff line number Diff line change
@@ -1,37 +1,45 @@
simulateModel("IBPSA.Fluid.Storage.Validation.StratifiedLoadingUnloading", tolerance=1e-6, stopTime=14400, method="CVode", resultFile="StratifiedLoadingUnloading");
createPlot(id = 1,
position = {10, 30, 719, 600},
filename = "StratifiedLoadingUnloading.mat",
y = {"tanEnh.vol[1].T", "tanEnh.vol[2].T", "tanEnh.vol[3].T", "tanEnh.vol[4].T", "tanEnh.vol[5].T", "tanEnh.vol[6].T", "tanEnh.vol[7].T"},
range = {0, 15000.0, 55.0, 15.0},
createPlot(id=1,
position={10, 30, 719, 603},
y={"tanEnh.vol[1].T", "tanEnh.vol[2].T", "tanEnh.vol[3].T", "tanEnh.vol[4].T", "tanEnh.vol[5].T", "tanEnh.vol[6].T", "tanEnh.vol[7].T"},
range={0.0, 15000.0, 10.0, 50.0},
subPlot=101,
colors={{28,108,200}, {238,46,47}, {0,140,72}, {217,67,180}, {0,0,0}, {162,29,33}, {244,125,35}},
timeUnit="s",
displayUnits={"degC", "degC", "degC", "degC", "degC", "degC", "degC"},
autoscale = true,
autoerase = true,
autoreplot = true,
grid = true,
color = true,
leftTitleType = 1,
bottomTitleType = 1);
createPlot(id = 1,
position = {10, 30, 719, 200},
y = {"dHTan.y", "dHTanEnh.y"},
range = {0, 14500.0, 60.0, 10.0},
createPlot(id=1,
position={10, 30, 719, 603},
y={"dHTan.y", "dHTanEnh.y"},
range={0.0, 15000.0, -5000000.0, 10000000.0},
subPlot=102,
colors={{28,108,200}, {238,46,47}},
timeUnit="s",
autoscale = true,
autoerase = true,
autoreplot = true,
grid = true,
color = true,
subPlot = 3,
leftTitleType = 1,
bottomTitleType = 1);
createPlot(id = 1,
position = {10, 30, 719, 200},
y = {"tan.vol[1].T", "tan.vol[2].T", "tan.vol[3].T", "tan.vol[4].T", "tan.vol[5].T", "tan.vol[6].T", "tan.vol[7].T"},
range = {0, 14500.0, 60.0, 10.0},
createPlot(id=1,
position={10, 30, 719, 603},
y={"tan.vol[1].T", "tan.vol[2].T", "tan.vol[3].T", "tan.vol[4].T", "tan.vol[5].T","tan.vol[6].T", "tan.vol[7].T"},
range={0.0, 15000.0, 10.0, 50.0},
subPlot=103,
colors={{28,108,200}, {238,46,47}, {0,140,72}, {217,67,180}, {0,0,0}, {162,29,33}, {244,125,35}},
timeUnit="s",
displayUnits={"degC", "degC", "degC", "degC", "degC", "degC", "degC"},
autoscale = true,
autoerase = true,
autoreplot = true,
grid = true,
color = true,
subPlot = 2,
leftTitleType = 1,
bottomTitleType = 1);