Guard launching duplicated fluentd instance with same configuration
Concept; Inject blocking code to /usr/sbin/fluentd. Before: If you launch multiple Fluentd instance with same configuration file, it causes a disaster with inconsistent processed buffer or pos file. After: Detect fluentd service's main process and fetch FLUENT_CONF. if configuration is same as spawned process, abort it. It can block the following conditions are met: * fluentd is launched as a systemd service. configuration file is specified via FLUENT_CONF in fluentd.service. * manually try to launch fluentd with same configuration file like this: sudo /usr/sbin/fluentd -c /etc/fluent/fluentd.conf sudo /usr/sbin/fluentd sudo /opt/fluent/bin/fluentd -c /etc/fluent/fluentd.conf sudo /opt/fluent/bin/fluentd Note that following case doen't resolved. * /usr/sbin/fluentd -c /etc/fluent/fluentd.conf * /usr/sbin/fluentd * /opt/fluent/bin/fluentd -c /etc/fluent/fluentd.conf * /opt/fluent/bin/fluentd This is because there is no appropriate privilege to retrieve command line parameters. NOTE: Windows is out of scope in this PR. Signed-off-by: Kentaro Hayashi <[email protected]>
- Loading branch information
Showing
10 changed files
with
146 additions
and
1 deletion.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,103 @@ | ||
require 'optparse' | ||
module Fluent | ||
class ConflictDetector | ||
def self.linux? | ||
/linux/ === RUBY_PLATFORM | ||
end | ||
|
||
def self.under_systemd?(pid) | ||
pid == 1 or @pidmap[@pidmap[pid]] == 1 | ||
end | ||
|
||
def self.running_fluentd_conf | ||
unless linux? | ||
return nil | ||
end | ||
|
||
@pidmap = {} | ||
IO.popen(["/usr/bin/ps", "-e", "-o", "uid,pid,ppid,cmd"]) do |_io| | ||
_io.readlines.each do |line| | ||
uid, pid, ppid, cmd = line.split(' ', 4) | ||
# skip current running process | ||
next if Process.pid == pid.to_i | ||
@pidmap[pid.to_i] = ppid.to_i | ||
if cmd and cmd.chomp.include?("fluentd") and under_systemd?(pid.to_i) | ||
# check only under systemd control | ||
File.open("/proc/#{pid.to_i}/environ") do |file| | ||
conf = file.read.split("\u0000").select { |entry| entry.include?("FLUENT_CONF") } | ||
return conf.first.split('=').last unless conf.empty? | ||
end | ||
end | ||
end | ||
end | ||
return nil | ||
end | ||
end | ||
|
||
class FakeOptionParser < OptionParser | ||
attr_reader :config_path | ||
def initialize | ||
@config_path = nil | ||
@opt = OptionParser.new | ||
@opt.on('-c', '--config VAL') { |v| | ||
@config_path = v | ||
} | ||
@opt.on('-s', '--setup DIR') | ||
@opt.on('--dry-run') | ||
@opt.on('--show-plugin-config=PLUGIN') | ||
@opt.on('-p', '--plugin DIR') | ||
@opt.on('-I PATH') | ||
@opt.on('-r NAME') | ||
@opt.on('-d', '--daemon PIDFILE') | ||
@opt.on('--under-supervisor') | ||
@opt.on('--no-supervisor') | ||
@opt.on('--workers NUM') | ||
@opt.on('--user USER') | ||
@opt.on('--group GROUP') | ||
@opt.on('--umask UMASK') | ||
@opt.on('-o', '--log PATH') | ||
@opt.on('--log-rotate-age AGE') | ||
@opt.on('--log-rotate-size BYTES') | ||
@opt.on('--log-event-verbose') | ||
@opt.on('-i', '--inline-config CONFIG_STRING') | ||
@opt.on('-h', '--help') | ||
end | ||
|
||
def parse(argv) | ||
@opt.parse(argv) | ||
end | ||
|
||
end | ||
end | ||
|
||
begin | ||
running_fluentd_conf = Fluent::ConflictDetector.running_fluentd_conf | ||
unless Fluent::ConflictDetector.under_systemd?(Process.pid) | ||
if ENV["FLUENT_CONF"] and ENV["FLUENT_CONF"] == running_fluentd_conf | ||
# /usr/sbin/fluentd sets FLUENT_CONF=/etc/fluent/fluentd.conf by default | ||
# If it matches with running other instance, abort it | ||
puts "Error: can't start duplicate Fluentd instance with same #{ENV['FLUENT_CONF']}" | ||
exit 2 | ||
else | ||
# /opt/fluent/bin/fluentd does not set FLUENT_CONF=/etc/fluent/fluentd.conf, | ||
# if -c option is given from command line, check and abort it. | ||
unless ARGV.empty? | ||
# preflight with dummy parser | ||
opt = Fluent::FakeOptionParser.new | ||
begin | ||
opt.parse(ARGV) | ||
if opt.config_path and opt.config_path == running_fluentd_conf | ||
puts "Error: can't start duplicate Fluentd instance with same #{running_fluentd_conf}" | ||
exit 2 | ||
end | ||
rescue | ||
end | ||
end | ||
end | ||
end | ||
rescue Errno::EACCES | ||
# e.g. unprivileged access error, can't detect duplicated instance from command line parameter. | ||
rescue Errno::ENOENT | ||
# e.g. can't detect duplicated instance from ps. | ||
end | ||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters