Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Zoe Gen1: Add more info about which CAN messages are present #674

Open
wants to merge 1 commit into
base: main
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
40 changes: 36 additions & 4 deletions Software/src/battery/RENAULT-ZOE-GEN1-BATTERY.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -13,6 +13,8 @@ Still TODO:
- Fix the missing cell96 issue (Only cells 1-95 is shown)
- Find current sensor value (OVMS code reads this from inverter, which we dont have)
- Figure out why SOH% is not read (low prio)
- Most likely relates to the CAN message not being present on 41kWh packs
- Automatically detect if we are on 22 or 41kWh battery
/*

/* Do not change code below unless you are sure what you are doing */
Expand Down Expand Up @@ -152,22 +154,52 @@ void update_values_battery() { //This function maps all the values fetched via
}

void receive_can_battery(CAN_frame rx_frame) {
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
switch (rx_frame.ID) {
case 0x427:
case 0x155: //10ms - Unknown content
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
break;
case 0x427: // NOTE: Not present on 41kWh battery!
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
LB_Charge_Power_W = rx_frame.data.u8[5] * 300;
LB_kWh_Remaining = (((((rx_frame.data.u8[6] << 8) | (rx_frame.data.u8[7])) >> 6) & 0x3ff) * 0.1);
break;
case 0x42E: //HV SOC & Battery Temp & Charging Power
case 0x42E: //NOTE: Not present on 41kWh battery! HV SOC & Battery Temp & Charging Power
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
LB_Battery_Voltage = (((((rx_frame.data.u8[3] << 8) | (rx_frame.data.u8[4])) >> 5) & 0x3ff) * 0.5); //0.5V/bit
LB_Average_Temperature = (((((rx_frame.data.u8[5] << 8) | (rx_frame.data.u8[6])) >> 5) & 0x7F) - 40);
break;
case 0x424:
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
//Sent only? by 41kWh battery (potential use for detecting which generation we are on)
break;
case 0x425:
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
//Sent only? by 41kWh battery (potential use for detecting which generation we are on)
break;
case 0x445:
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
//Sent only? by 41kWh battery (potential use for detecting which generation we are on)
break;
case 0x4AE:
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
//Sent only? by 41kWh battery (potential use for detecting which generation we are on)
break;
case 0x4AF:
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
//Sent only? by 41kWh battery (potential use for detecting which generation we are on)
break;
case 0x654: //SOC
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
LB_SOC = rx_frame.data.u8[3];
break;
case 0x658: //SOH
case 0x658: //SOH - NOTE: Not present on 41kWh battery!
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
LB_SOH = (rx_frame.data.u8[4] & 0x7F);
break;
case 0x659:
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
//Sent only? by 41kWh battery (potential use for detecting which generation we are on)
break;