SMA CAN H: Fix charge allowed message #183

Merged
merged 1 commit into from
Feb 16, 2024
Merged

Conversation

dalathegreat
Copy link
Owner

What

This PR fixes a bug that caused SMA Sunnyboy Storage inverters to never use the battery

Why

The bit in the 4D8 message was not set

How

Setting the bit to 3 allows discharge/charge. Setting it to 2 stops charging. We now set this bit depending on bms_status!

@dalathegreat dalathegreat merged commit fe124fc into main Feb 16, 2024
36 checks passed
@dalathegreat dalathegreat deleted the bugfix/SMA-H-CAN branch February 16, 2024 18:53