1 parent 3aa3d8e commit 19e3372
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion Software/src/battery/TESLA-MODEL-3-BATTERY.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -156,7 +156,7 @@ static const char* hvilStatusState[] = {"NOT OK",
#define MIN_CELL_VOLTAGE_NCA_NCM 2950 //Battery is put into emergency stop if one cell goes below this value
#define MAX_CELL_DEVIATION_NCA_NCM 500 //LED turns yellow on the board if mv delta exceeds this value

#define MAX_CELL_VOLTAGE_LFP 3450 //Battery is put into emergency stop if one cell goes over this value
#define MAX_CELL_VOLTAGE_LFP 3500 //Battery is put into emergency stop if one cell goes over this value
#define MIN_CELL_VOLTAGE_LFP 2800 //Battery is put into emergency stop if one cell goes over this value
#define MAX_CELL_DEVIATION_LFP 150 //LED turns yellow on the board if mv delta exceeds this value

Expand Down