This is binding to native library libmodbus (http://libmodbus.org/).
Now working only in *nix system.
Module have native function and framework.
var log = console.log;
var mb = require('modbus').create();
// create device memory map
var data = mb.createData({ countReg: 5, countBit: 2 });
data.setReg(2, 321);
data.setBit(1, true);
data.dumpData(); // show memory map
// create slave device
var ctx = mb.createSlave({
// connection type and params
con: mb.createConTcp('127.0.0.1', 1502),
//con: mb.createConRtu(1, '/dev/ttyS0', 9600),
// data map
data: data,
// callback functions
onQuery: function () {
log('onQuery');
//ctx.dumpData();
log(ctx.getBits(0, 2));
},
onDestroy: function () {
log('onDestroy');
}
});
// destroy device
//setTimeout(function () {
// ctx.destroy();
//}, 5000);
var log = console.log;
var mb = require('modbus').create();
mb.onError(function (msg) {
log('ERROR', msg);
});
// create master device
var ctx = mb.createMaster({
// connection type and params
con: mb.createConTcp('127.0.0.1', 1502),
//con: mb.createConRtu(1, '/dev/ttyS1', 9600),
// callback functions
onConnect: function () {
log('onConnect');
log(ctx.getReg(2));
ctx.setBit(1, false);
ctx.destroy();
},
onDestroy: function () {
log('onDestroy');
}
});
WARNING: native function blocking all processes!
var log = console.log;
var native = require('modbus').native;
// create context
var ctx = native.new_tcp("127.0.0.1", 1502);
// connect to slave device
native.connect(ctx);
// get value
var result = [];
native.read_registers(ctx, 2, 1, result);
log(result[0]);
// set value
native.write_bit(ctx, 1, native.OFF);
// close context
native.close(ctx);
native.free(ctx);
Create data map (use only slave device).
arg[Object] - having next fields:
- dataBit[Array] - array boolean values of read/write bits
- dataInputBit[Array] - array boolean values of read only bits
- dataReg[Array] - array 16bit unsigned integer values of read/write register
- dataInputReg[Array] - array 16bit unsigned integer values of read only register
- countBit[Number] - created empty dataBit array
- countInputBit[Number] - created empty dataInputBit array
- countReg[Number] - created empty dataReg array
- countInputReg[Number] - created empty dataInputReg array
- retur[Object] - data object with methods:
getBit(adr) - get read/write bit value
- adr[Number] - bit address
- return[Boolean] - bit value
getInputBit(adr) - get read only bit value
getReg(adr) - get read/write register value
getInputReg(adr) - get read only register value
getBits(adr, count) - get read/write bits array value
- adr[Number] - first bit address
- count[Number] - count readed bits
- return[Array] - array boolean values readed bits
getInputBits(adr, count) - get read only bits array value
getRegs(adr, count) - get read/write registers array value
getInputRegs(adr, count) - get read only registers array value
setBit(adr, val) - set read/write bit value
- adr[Number] - address bit
- val[Boolean] - value bit
setInputBit(adr, val) - set read only bit value
setReg(adr, val) - set read/write register value
setInputReg(adr, val) - set read only register value
setBits(adr, val) - set read/write bits array value
- adr[Number] - first bit address
- val[Array] - array boolean values
setInputBits(adr, val) - set read only bits array value
setRegs(adr, val) - set read/write registers array value
setInputRegs(adr, val) - set read only registers array value
dumpData() - show memory dump
Create connection object for tcp connection.
- ip[String] - ip address modbus slave device, default "127.0.0.1"
- port[Number] - tcp port modbus slave device, default 502
- max[Number] - max connections for slave device, default 1
Create connection object for serial port connection.
- id[Number] - id slave device on line, default 1
- device[String] - name of serial port, default "/dev/ttyS0"
- baud[Number] - using baudrate speed, the allowed values are 9600, 19200, 57600, 115200, etc, default 115200
- parity[String] - using parity control, the allowed values are "N", "E", "O", default "N"
- dataBit[Number] - count data bit, the allowed values are 5, 6, 7 and 8, default 8
- stopBit[Number] - using stop bit, the allowed values are 1 and 2, default 1
Create slave modbus device
arg[Object] - having next fields:
- con[Object] - connect object, created createConTcp/createConRtu function
- data[Object] - memory map object, created createData function
- onQuery[Function] - callback function, called if master device send any query request
- onDestroy[Function] - callback function, called if device destroyed
- return[Object] - data object (context) with methods:
destroy() - destroyed slave device
and all data object api
Create master modbus device
- con[Object] - connect object, created createConTcp/createConRtu function
- onConnect[Function] - callback function, called if connect complete to slave device
- onDestroy[Function] - callback function, called if device destroyed
- return[Object] - data object (context) with methods:
destroy() - destroyed slave device
and all data object api without setInput*