# microvascular | ||
# MR simulator for microvascular network | ||
|
||
This program aims to simulate the behaviour of spins under a certain MR sequence in a microvascular network. Breifly, the susceptibility variation between blood and tissue leads to local field inhomogeneity which accordingly can be used to generate an MR contrast. The program tries to perform a Monte-Carlo simulation over range of spins which are randomly distributed and move in presense of user defined magnetic field. Here are example plots obtained from the simulator where show BOLD sensitivity as a function of vessel size for Gradient Echo (GRE) and Spin Echo (SE) seqeuences. | ||
|
||
![](./images/gre_se.png) | ||
|
||
Some [literature](#Literature) are provided as reference to get a better feeling of what are intended to get from this kind of simulations. | ||
|
||
Simulator is written in C++ and utilizes CUDA to run in GPU. Therefore, it is possible to run a simulation within a short period of time provided that a good GPU presents. Simulator can detect all GPU cards, if there is more than one, and can distribute the task to run in parallel in multiple GPUs. This is helpful if you wan to run the simulator in HPC cluster with mutliple GPUs available in a node. | ||
|
||
**This manual can be outdated. It is written based on commit [38ae16d043](https://github.com/aghaeifar/microvascular/tree/38ae16d043eb470c7c92450debe96bdc736a814a).** | ||
|
||
|
||
## How to run | ||
``` | ||
./sim_microvascular config1.ini config2.ini ... | ||
``` | ||
|
||
## How to compile | ||
Linux: | ||
``` | ||
nvcc microvascular_gpu.cu -Xptxas -v -O3 -arch=compute_86 -code=sm_86 -Xcompiler -fopenmp -o sim_microvascular | ||
``` | ||
Windows: | ||
``` | ||
nvcc microvascular_gpu.cu -Xptxas -v -O3 -arch=compute_86 -code=sm_86 -Xcompiler /openmp -std=c++17 -o sim_microvascular | ||
``` | ||
You should replace 86 in *compute_86* and *sm_86* with compute capability of your GPU. To check compute capability of your GPU run following command in terminal: | ||
```bash | ||
nvidia-smi --query-gpu=compute_cap --format=csv | ||
``` | ||
My GPU is NVIDIA RTX A4000 and the command above gives me: | ||
``` | ||
compute_cap | ||
8.6 | ||
``` | ||
|
||
## Configuration files | ||
Configruation file is a text based [ini file](https://en.wikipedia.org/wiki/INI_file) used to provide simulation parameters for simulator. Simulator can accept more than one configuration to simulation several configurations. A configuration file can inherit from another configuration file to avoid writing repetitive simulation parmeters. All the possible parameters are provided in [config_default.ini](./inputs/config_default.ini). | ||
|
||
## Binary file format | ||
### Fieldmap | ||
Simulator needs one or more fieldmap(s) and mask(s) for simulation. The fieldmap unit is Tesla and must be normalized to the static magnetic field where is intended to be used for simulation. Fieldmap file is stored in binary format with this structure starting from the beginning of file: | ||
|
||
1. Size = 3 unsigned int (3*4 bytes in total) representing 3D volume size. | ||
2. Length = 3 single precision float (3*4 bytes in total) representing length in meter for each dimension. | ||
3. Fieldmap = n single precision float (n*4 bytes in total) where n = product of **size** array elements. Field map is stored in [column-major order](https://en.wikipedia.org/wiki/Row-_and_column-major_order). | ||
4. Mask = n unsigned char (n bytes in total) where n = product of **size** array elements. Mask is stored in column-major order. | ||
|
||
The path to fieldmap is set in configuration file. | ||
|
||
### Other inputs | ||
M0 and XYZ0 in configuration file are two additional inputs which define starting magnization and initial spatial position of spins. Please note that initial spatial positions must not intersect with mask. If M0 and XYZ0 are not provided or is empty, staring magnization of (0,0,1) and random positioning will be used, respectively. | ||
|
||
binary file containing M0 and XYZ0 is of size 3*number spins single precision float which are stored in the file with this pattern: | ||
``` | ||
x0 y0 z0 x1 y1 z1 x2 y2 z2 .... xn yn zn | ||
``` | ||
unit for spatial position is meter. | ||
|
||
### Outputs | ||
Simulator saves M1 and XYZ1 (optional) when simulation finishes. The path for M1 and XYZ1 can be provided in configuration file. M1 and XYZ1 represents spins magnetization and spatial positions at the end of sequence, respectively. They are stored in a binary file with this format: | ||
1. header size = 1 unsigned int (4 bytes in total) representing header size in byte | ||
2. size = 4 unsigned int (4*4 bytes in total) representing 4D volume size. It is usualy 3 x number of spins x GPU_devices x Number of vessel sizes | ||
3. additional info = header size - 16 bytes containing additional information. Here, e.g., different scales for vessel size | ||
4. M1 or XYZ1 = stored in column-major order | ||
|
||
A MATLAB script is provided to read output files. See [read_microvascular.m](./outputs/read_microvascular.m). | ||
|
||
## Literature | ||
There are many nice papers published about simulation of BOLD signal in vessels network. A few are listed here for reference: | ||
|
||
- Bieri O, Scheffler K. Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession. NMR Biomed. 2007 Feb;20(1):1-10. doi: 10.1002/nbm.1079. PMID: 16947639. | ||
- Báez-Yánez MG, Ehses P, Mirkes C, Tsai PS, Kleinfeld D, Scheffler K. The impact of vessel size, orientation and intravascular contribution on the neurovascular fingerprint of BOLD bSSFP fMRI. Neuroimage. 2017 Dec;163:13-23. doi: 10.1016/j.neuroimage.2017.09.015. Epub 2017 Sep 8. PMID: 28890417; PMCID: PMC5857886. | ||
- Boxerman JL, Hamberg LM, Rosen BR, Weisskoff RM. MR contrast due to intravascular magnetic susceptibility perturbations. Magn Reson Med. 1995 Oct;34(4):555-66. doi: 10.1002/mrm.1910340412. PMID: 8524024. | ||
- Khajehim M, Nasiraei Moghaddam A. Investigating the spatial specificity of S2-SSFP fMRI: A Monte Carlo simulation approach. Magn Reson Imaging. 2017 Apr;37:282-289. doi: 10.1016/j.mri.2016.11.016. Epub 2016 Nov 24. PMID: 27890778. | ||
- Weisskoff RM, Zuo CS, Boxerman JL, Rosen BR. Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn Reson Med. 1994 Jun;31(6):601-10. doi: 10.1002/mrm.1910310605. PMID: 8057812. | ||
- Scheffler K, Engelmann J, Heule R. BOLD sensitivity and vessel size specificity along CPMG and GRASE echo trains. Magn Reson Med. 2021 Oct;86(4):2076-2083. doi: 10.1002/mrm.28871. Epub 2021 May 31. PMID: 34056746. |
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters