-
Notifications
You must be signed in to change notification settings - Fork 2
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Upper grounding strip #1
Open
Vijay1707
wants to merge
13
commits into
master
Choose a base branch
from
UpperGroundingStrip
base: master
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Selections and Terminals are created correctly for inner strips, but resistors have not been configured to connect inner strips to anode, cathode and each other.
This computes (finally) with added left hand side resistors. FSENumber=4 though, so we now need to ground the grounding strips and change FSENumber to 80.
Selections were made for ground strips and they were grounded.
80 Strip geometry opens in COMSOL, we're now testing to see if Electric Field computes.
Currently tring to create an upper ground strip to stop escaping field and potential.
Initial attempt to create upper grounding strip. In COMSOL there is a meshing error. Also the physics and material domains need to be changed.
In this commit, the geometry, selections and terminal has been created for the upper grounding strip, and the heights of grounding strips 2 and 3 were increased to touch the upper gounding strip.
Class file created by this code successfully creates upper grounding strip to removed external field.
Changed upper ground strip parameters: rmin=rmin+insulationwidth rmax=rmax-insulationwidth
This successfully creates shortened upper grounding strip, however domains for materials and physics work ONLY for 60 strips. If FSENumber is changed, domains of materials and physics must be adjusted. Need universal domains that accountfor FSENumber.
UpperStrips.java will be used to create an array of upper grounding strips with gaps so we can observe the potential leaks with different ground strip setups.
Saving progress on UpperStrips.java to work on shortened upper ground strip. Next step on this front is to move upperstrips.java code to tpc.java so we can open TPCMirror.class with upper ground strip array created in TPC.java.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
No description provided.