4 changes: 3 additions & 1 deletion .golangci.yml
Original file line number Diff line number Diff line change
Expand Up @@ -18,11 +18,13 @@ issues:
- path: 'snmp/snmpwalk.go'
linters:
- funlen
- path: 'hp/mib/cpq_sm_cntrl.go'
linters:
- golint

linters:
enable-all: true
disable:
- golint # TODO fix
- revive
- cyclop
- depguard
Expand Down
99 changes: 36 additions & 63 deletions README.md
Original file line number Diff line number Diff line change
@@ -1,13 +1,14 @@
check_hp_firmware
=================
# check_hp_firmware

![Go build](https://github.com/NETWAYS/check_hp_firmware/workflows/Go/badge.svg?branch=master)
Monitoring check plugin to verify HPE controllers an SSD disks are not affected by certain vulnerabilities.

<!-- Note: Update `Readme` in main.go when changing this! -->
*Note:* This plugin was initially named `check_hp_disk_firmware`.

Icinga / Nagios check plugin to verify HPE controllers an SSD disks are not affected by certain vulnerabilities.
Current Limitations:

**HPE Controllers**
* No SNMPv3 support is implemented

## HPE Controllers

> HPE Smart Array SR Gen10 Controller Firmware Version 2.65 (or later) provided in the (HPE document a00097210) is
> required to prevent a potential data inconsistency on select RAID configurations with Smart Array Gen10 Firmware
Expand All @@ -24,15 +25,15 @@ The check will alert you with a CRITICAL when the firmware is in the affected ra
And it will add a short note when `firmware older than affected` or `firmware has been updated`. At the moment the
plugin does not verify configured logical drives, but we believe you should update in any case.

**HPE SSD SAS disks**
## HPE SSD SAS disks

> HPE SAS Solid State Drives - Critical Firmware Upgrade Required for Certain HPE SAS Solid State Drive Models to
> Prevent Drive Failure at 32,768 or 40,000 Hours of Operation

The check will raise a CRITICAL when the drive needs to be updated with the note `affected by FW bug`, and when
the drive is patched with `firmware update applied`.

**HPE Integrated Lights-Out**
## HPE Integrated Lights-Out

Multiple security vulnerabilities have been identified in Integrated Lights-Out 3 (iLO 3),
Integrated Lights-Out 4 (iLO 4), and Integrated Lights-Out 5 (iLO 5) firmware. The vulnerabilities could be remotely
Expand All @@ -41,41 +42,39 @@ firmware to mitigate these vulnerabilities.

The check will raise a CRITICAL when the Integrated Lights-Out needs to be updated. Below you will find a list with
the least version of each Integrated Lights-Out version:

- HPE Integrated Lights-Out 3 (iLO 3) firmware v1.93 or later.
- HPE Integrated Lights-Out 4 (iLO 4) firmware v2.75 or later
- HPE Integrated Lights-Out 5 (iLO 5) firmware v2.18 or later.

Please see support documents from HPE:
* [a00092491](https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=emr_na-a00092491en_us)
* [a00097382](https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00097382en_us)
* [a00097210](https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00097210en_us)
* [HPESBHF04012](https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbhf04012en_us)

**IMPORTANT:** Read the documentation for HPE! The plugin and its documentation is a best effort to find and detect
affected hardware. There is ABSOLUTELY NO WARRANTY, see the license!
**IMPORTANT:** Always read the latest HPE Security Bulletins. https://support.hpe.com/connect/s/securitybulletinlibrary

> **Note:** This plugin was initially named check_hp_disk_firmware
The plugin and its documentation is a best effort to find and detect affected hardware. There is no warranty, see the license.

## Usage

Arguments:

-H, --hostname string SNMP host (default "localhost")
-c, --community string SNMP community (default "public")
-P, --protocol string SNMP protocol (default "2c")
--timeout int SNMP timeout in seconds (default 15)
--snmpwalk-file string Read output from snmpwalk
--ignore-ilo-version Don't check the ILO version
-4, --ipv4 Use IPv4
-6, --ipv6 Use IPv6
-V, --version Show version
--debug Enable debug output
```
-H, --hostname string SNMP host (default "localhost")
-c, --community string SNMP community (default "public")
-P, --protocol string SNMP protocol (default "2c")
--timeout int SNMP timeout in seconds (default 15)
--snmpwalk-file string Read output from snmpwalk
--ignore-ilo-version Don't check the ILO version
-4, --ipv4 Use IPv4
-6, --ipv6 Use IPv6
-V, --version Show version
--debug Enable debug output
```

Simply run the command:

$ ./check_hp_firmware -H localhost -c public
```bash
check_hp_firmware -H localhost -c public
```

## Installation
# Installation

This is a Golang project, either download the binary from the releases:

Expand All @@ -85,11 +84,11 @@ Also see the included [CheckCommand for Icinga 2](icinga2.conf).

You can download or build the project locally with go:

$ go get github.com/NETWAYS/check_hp_cve

$ git clone https://github.com/NETWAYS/check_hp_firmware
$ cd check_hp_firmware/
$ go build -o check_hp_firmware .
```bash
git clone https://github.com/NETWAYS/check_hp_firmware
cd check_hp_firmware/
make build
```

## Example

Expand All @@ -99,43 +98,17 @@ You can download or build the project locally with go:
[OK] controller (4) model=p408e-p serial=XXX firmware=1.65 - firmware older than affected
[OK] (0.9 ) model=MO003200JWFWR serial=XXX firmware=HPD2 hours=8086
[OK] (0.11) model=EK000400GWEPE serial=XXX firmware=HPG0 hours=8086
[OK] (0.12) model=EK000400GWEPE serial=XXX firmware=HPG0 hours=8086
[OK] (0.14) model=MO003200JWFWR serial=XXX firmware=HPD2 hours=8086
[OK] (4.0 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.1 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.2 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.3 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.4 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.5 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.6 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.24) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.25) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.26) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.27) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.28) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.29) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.30) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.31) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.50) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.51) model=MO003200JWFWR serial=XXX firmware=HPD2 hours=7568
[OK] (4.52) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.53) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.54) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.55) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.56) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.75) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.76) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.77) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.78) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.79) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.80) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.81) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied

## Limitations

* No SNMPv3 support is implemented

## Contribute
# Contribute

If you find bugs or want to add features, please open an issue or pull-request on GitHub.

Expand All @@ -148,7 +121,7 @@ so we can provide you with a secure upload link, that won't be shared with publi

## Technical Details

Supported hardware is split into modules: [hp/cntlr](hp/cntlr) [hp/phy_drv](hp/phy_drv) [hp/ilo](hp/ilo)
Supported hardware is split into modules: [hp/cntlr](hp/cntlr) [hp/drive](hp/drive) [hp/ilo](hp/ilo)

Known models and affected firmware is documented in: [hp/cntlr/firmware_data.go](hp/cntlr/firmware_data.go) [hp/phy_drv/firmware_data.go](hp/phy_drv/firmware_data.go) [hp/ilo/firmware_data.go](hp/ilo/firmware_data.go)

Expand All @@ -158,7 +131,7 @@ the accompanying firmware and status functions.
The check reads the `cpqDaCntlrTable` and `cpqDaPhyDrvTable` tables from SNMP, which should be available over the
IPMI agent or the locally installed HP tools, hooked into the SNMP daemon of the operating system.

## License
# License

Copyright (C) 2020 NETWAYS <[email protected]>

Expand Down
6 changes: 3 additions & 3 deletions hp/cntlr/controller.go
Original file line number Diff line number Diff line change
Expand Up @@ -9,7 +9,7 @@ import (
)

type Controller struct {
Id string
ID string
Model string
FwRev string
Serial string
Expand All @@ -24,7 +24,7 @@ func NewControllerFromTable(t *CpqDaCntlrTable, id string) (*Controller, error)
var err error

controller := &Controller{}
controller.Id = id
controller.ID = id

modelI, err := t.GetIntValue(id, mib.CpqDaCntlrModel)
if err != nil {
Expand Down Expand Up @@ -78,7 +78,7 @@ func GetControllersFromTable(t *CpqDaCntlrTable) ([]*Controller, error) {

func (d *Controller) GetNagiosStatus() (int, string) {
description := fmt.Sprintf("controller (%s) model=%s serial=%s firmware=%s",
d.Id, d.Model, strings.TrimSpace(d.Serial), d.FwRev)
d.ID, d.Model, strings.TrimSpace(d.Serial), d.FwRev)

if d.Status != "ok" {
return check.Critical, description + " - status: " + d.Status
Expand Down
3 changes: 2 additions & 1 deletion hp/cntlr/firmware_test.go
Original file line number Diff line number Diff line change
@@ -1,8 +1,9 @@
package cntlr

import (
"github.com/stretchr/testify/assert"
"testing"

"github.com/stretchr/testify/assert"
)

type testInfo struct {
Expand Down
8 changes: 4 additions & 4 deletions hp/phy_drv/drive.go → hp/drive/drive.go
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
package phy_drv
package drive

import (
"fmt"
Expand All @@ -8,7 +8,7 @@ import (
)

type PhysicalDrive struct {
Id string
ID string
Model string
FwRev string
Serial string
Expand All @@ -24,7 +24,7 @@ func NewPhysicalDriveFromTable(t *CpqDaPhyDrvTable, id string) (*PhysicalDrive,
var err error

drive := &PhysicalDrive{
Id: id,
ID: id,
}

drive.Model, err = t.GetStringValue(id, mib.CpqDaPhyDrvModel)
Expand Down Expand Up @@ -78,7 +78,7 @@ func GetPhysicalDrivesFromTable(t *CpqDaPhyDrvTable) ([]*PhysicalDrive, error) {

func (d *PhysicalDrive) GetNagiosStatus() (int, string) {
description := fmt.Sprintf("physical drive (%-4s) model=%s serial=%s firmware=%s hours=%d",
d.Id, d.Model, d.Serial, d.FwRev, d.Hours)
d.ID, d.Model, d.Serial, d.FwRev, d.Hours)

if d.Status != "ok" {
return check.Critical, description + " - status: " + d.Status
Expand Down
7 changes: 4 additions & 3 deletions hp/phy_drv/drive_test.go → hp/drive/drive_test.go
Original file line number Diff line number Diff line change
@@ -1,17 +1,18 @@
package phy_drv
package drive

import (
"testing"

"github.com/NETWAYS/go-check"
"github.com/stretchr/testify/assert"
"testing"
)

const affectedDrive = "VO0480JFDGT"
const affectedDriveFixed = "HPD8"

func TestPhysicalDrive_GetNagiosStatus(t *testing.T) {
drive := &PhysicalDrive{
Id: "1.1",
ID: "1.1",
Model: "OTHERDRIVE",
FwRev: "HPD1",
Serial: "ABC123",
Expand Down
2 changes: 1 addition & 1 deletion hp/phy_drv/drives.go → hp/drive/drives.go
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
package phy_drv
package drive

import (
"github.com/NETWAYS/check_hp_firmware/hp/mib"
Expand Down
2 changes: 1 addition & 1 deletion hp/phy_drv/firmware.go → hp/drive/firmware.go
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
package phy_drv
package drive

import (
"fmt"
Expand Down
2 changes: 1 addition & 1 deletion hp/phy_drv/firmware_data.go → hp/drive/firmware_data.go
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
package phy_drv
package drive

// Source A: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us
// Version: 2
Expand Down
5 changes: 3 additions & 2 deletions hp/phy_drv/firmware_test.go → hp/drive/firmware_test.go
Original file line number Diff line number Diff line change
@@ -1,8 +1,9 @@
package phy_drv
package drive

import (
"github.com/stretchr/testify/assert"
"testing"

"github.com/stretchr/testify/assert"
)

const testModelA = "VO0480JFDGT"
Expand Down
22 changes: 12 additions & 10 deletions hp/ilo/firmware.go
Original file line number Diff line number Diff line change
Expand Up @@ -15,6 +15,8 @@ type Ilo struct {
RomRevision string
}

// GetIloInformation retrieves the iLO's Model and Rom Revision via SNMP
// and returns an Ilo struct.
func GetIloInformation(client gosnmp.Handler) (ilo *Ilo, err error) {
oidModel := []string{mib.CpqSm2CntlrModel + ".0"}
oidRev := []string{mib.CpqSm2CntlrRomRevision + ".0"}
Expand Down Expand Up @@ -43,6 +45,8 @@ func GetIloInformation(client gosnmp.Handler) (ilo *Ilo, err error) {
return
}

// GetNagiosStatus validates the iLO's data against the known models
// in this plugin.
func (ilo *Ilo) GetNagiosStatus() (state int, output string) {
// nolint: ineffassign
state = check.Unknown
Expand All @@ -67,7 +71,7 @@ func (ilo *Ilo) GetNagiosStatus() (state int, output string) {

output = fmt.Sprintf("Integrated Lights-Out %s revision %s ", modelInfo.Name, ilo.RomRevision)

if !CompareVersion(modelInfo.FixedRelease, ilo.RomRevision) {
if !isNewerVersion(modelInfo.FixedRelease, ilo.RomRevision) {
state = check.Critical
output += "- version too old, should be at least " + modelInfo.FixedRelease
} else {
Expand All @@ -78,16 +82,14 @@ func (ilo *Ilo) GetNagiosStatus() (state int, output string) {
return
}

func CompareVersion(required, current string) bool {
v, err := version.NewVersion(current)
if err != nil {
return false
}
// isNewerVersion compares the current version against the required version
func isNewerVersion(required, current string) bool {
currentVersion, cErr := version.NewVersion(current)
requiredVersion, rErr := version.NewVersion(required)

c, err := version.NewConstraint(">=" + required)
if err != nil {
panic(err)
if cErr != nil || rErr != nil {
return false
}

return c.Check(v)
return currentVersion.GreaterThanOrEqual(requiredVersion)
}