Skip to content

JanJaapKo/domoticz-GoodWeSEMS

 
 

Repository files navigation

Domoticz GoodWe Solar Inverter plugin (SEMS API)

This plugin provides information about your GoodWe solar inverter too Domoticz. This plugin has been made by analysing requests made by the GoodWe SEMS Portal website and following the API documentation provided by GoodWe.

This plugin was created by Dylian94 (/dylian94/domoticz-GoodWeSEMS) but that version is out of maintenance. Additional credits to Mark Ruys' gw2pvo for getting the API calls right.......

Important update note (v4)

Per version 4 (November 2023), I've updated the plugin to the Domoticz Extend Framework, which means the device definition is changed. To make sure that you still have your historical sensor data, please read the wiki.

Installation and setup

Follow the Domoticz guide on Using Python Plugins. Check limitations on the bottom of the page. The following Python modules should be installed. Login to a shell:

sudo apt-get update
sudo apt-get install python3-requests

Then, go to the domoticz plugin directory and clone this repository (eith SSH, requires git account):

cd domoticz/plugins
git clone [email protected]:janjaapko/domoticz-GoodWeSEMS.git

OR

Login to a shell, go to the domoticz plugin directory and clone this repository (with https, requires no git account):

cd domoticz/plugins
git clone https://github.com/JanJaapKo/domoticz-GoodWeSEMS.git

Restart Domoticz server, you can try one of these commands (on Linux):

sudo systemctl restart domoticz.service
sudo service domoticz.sh restart

Open the Domoticz interface and go to: Setup > Hardware. You can add new Hardware add the bottom, in the list of hardware types choose for: GoodWe inverter (via SEMS portal).

Follow the instructions shown in the form.

Updating

Login to a shell, go to the plugin directory inside the domoticz plugin directory and execute git pull:

cd domoticz/plugins/domoticz-GoodWeSEMS
git pull

Contributing

Even if you do not know how to develop software you can help by using the GitHub Issues for feature request or bug reports. If you DO know how to develop software please help improving this project by submitting pull-requests. Make sure to update and run the included unit tests (python plugin_test.py) prior to submitting

Current features

  1. Get all stations for a specific user account
  2. Automatically get data for all inverters (for one station)
  3. The following devices are added to Domoticz for each inverter:
Unit Description Type Remark
1 (Hardware name) - Inverter temperature (SN: (your S/N)) LaCrosse TX3
2 (Hardware name) - Inverter output current (SN: (your S/N)) Current
3 (Hardware name) - Inverter output voltage (SN: (your S/N)) Voltage
4 (Hardware name) - Inverter output power (SN: (your S/N)) kWh default: used
5 (Hardware name) - Inverter input 1 voltage (SN: (your S/N)) Voltage
6 (Hardware name) - Inverter input 1 Current (SN: (your S/N)) Current
7 (Hardware name) - Inverter input 2 voltage (SN: (your S/N)) Voltage
8 (Hardware name) - Inverter input 2 Current (SN: (your S/N)) Current
9 (Hardware name) - Inverter state (SN: (your S/N)) Selector Switch default: used
10 (Hardware name) - Solar inverter input 3 voltage (SN: (your S/N)) Voltage
11 (Hardware name) - Solar inverter input 3 Current (SN: (your S/N)) Current
12 (Hardware name) - Solar inverter input 4 voltage (SN: (your S/N)) Voltage
13 (Hardware name) - Solar inverter input 4 Current (SN: (your S/N)) Current
14 (Hardware name) - Inverter input 1 power (SN: (your S/N)) kWh default: used. calculated in plugin
15 (Hardware name) - Inverter input 2 power (SN: (your S/N)) kWh calculated in plugin
16 (Hardware name) - Inverter input 3 power (SN: (your S/N)) kWh calculated in plugin
17 (Hardware name) - Inverter input 4 power (SN: (your S/N)) kWh calculated in plugin
18 (Hardware name) - Inverter output frequency 1 Custom Sensor

There is a lot more information available trough the GoodWe API if you would like to have a specific feature added to this plugin please submit an issue as indicated in the paragraph above.

Current limitations

  1. You can only fetch data for 1 powerstation (which can consist of more than 1 inverter). The field Power Station ID is now mandatory
  2. The GoodWE API does not always respond in time, leading to errors like below. This is not a problem, data will be updated on the next try.
Error: Zonnepanelen: (Zonnepanelen) RequestException: HTTPSConnectionPool(host='eu.semsportal.com', port=443): Read timed out. (read timeout=10)
Error: Zonnepanelen: (Zonnepanelen) Failed to request data: Failed to call GoodWe API (too many retries)