Notifications
You must be signed in to change notification settings - Fork 1
/
q4.m
132 lines (107 loc) · 2.86 KB
/
q4.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
%% Q4) Outstanding Level: Grid-connected Mode and Islanded Mode Switch
% This script contains the code to run completed_microinverter_setup.slx
% Streamlined config script for full implementation
Ts = 1e-6;
Tes = 20*Ts; % electrical sampling time
Tcs = 100*Ts;
% Grid voltage
V_rms = 400;
V_dc = V_rms * sqrt(3) * sqrt(2);
% PLL
Wn = 2*pi*200;
DF = 0.707;
Ki_pll = (Wn^2);
Kp_pll = 2*DF / sqrt(1/Ki_pll);
f_center = 50;
% Damped LC filter
L1_filter = 1.5e-3;
L2_filter = 1.0e-3;
Rd_filter = 0.2;
C1_filter = 2e-6;
% Source: docs/inverter_output_LCL_Filter.pdf
F_damped_filter = 1/(2*pi) * sqrt((L1_filter+L2_filter)/(C1_filter*L1_filter*L2_filter));
% RL load
P_load = 10e3 / 3;
pf_load = 0.95;
V_rms = 400;
f = 50;
w = 2*pi*f;
R_load = (V_rms^2) * (pf_load^2) / P_load;
L_load = sqrt((R_load * V_rms^2)/P_load - R_load^2) / w;
% Controller parameters
% NOTE: We approximate the equivalent LC filter for the LCL damped filter
L_filter = 1.25e-3;
C_filter = 2e-6;
F_approx_filter = 1/(2*pi*sqrt(L_filter*C_filter));
% Current PI controller
Wn = 2*pi*100;
%DF = 0.707;
DF = 3.5;
Ki_current = L_filter*Wn^2;
Kp_current = 2*L_filter*DF*Wn;
% Voltage PI controller
Wn = 2*pi*30;
%DF = 0.707;
DF = 10.5;
Ki_voltage = C_filter*Wn^2;
Kp_voltage = 2*C_filter*DF*Wn;
% Power PI controller
Ki_power = 100;
Kp_power = 0;
%% Plot response of our system
% Get out transfer functions
s = tf('s');
Z_C = 1/(s*C_filter);
Z_RL = (L2_filter + L_load)*s + R_load;
Z_RC = Z_C + Rd_filter;
Z_L = s*L1_filter;
Z_RLC_parallel = 1/(1/Z_C + 1/Z_RL);
% T1 = I_inductor / V_in
T1 = 1/(Z_L + Z_RLC_parallel);
% T2 = Vo/Vin
T2 = Z_RLC_parallel / (Z_L + Z_RLC_parallel);
T2 = minreal(T2);
% T3 = I_load / Vin
% I_load = Vo/Z_RL
T3 = T2 * 1/Z_RL;
T3 = minreal(T3);
% H = I_inductor / V_outupt
% H = I_inductor / V_in * V_in / V_output
H = T1 / T2;
H = minreal(H);
% Controller responses
G1 = Kp_current + Ki_current/s;
G2 = Kp_voltage + Ki_voltage/s;
% T4 is our I1/Ir closed loop response for current controller
T4 = G1/(L1_filter*s + G1);
T4 = minreal(T4);
% T5 is our V0/Vr closed loop response for outer voltage controller
T5 = G1*G2/(H*L1_filter*s + s*C_filter*G1 + G1*G2);
T5 = minreal(T5);
% T6 is our simplified response for outer voltage controller
T6 = G2/(C_filter*s + G2);
T6 = minreal(T6);
% Response of power control
T7 = (Kp_power*s + Ki_power) / ((Kp_power+1)*s + Ki_power);
% Plot the responses
dt = linspace(0, 0.1, 10000);
[dy1,dt1] = step(T4, dt);
[dy2,dt2] = step(T5, dt);
[dy3,dt3] = step(T6, dt);
[dy4,dt4] = step(T7, dt);
step_info_1 = stepinfo(dy1, dt1);
step_info_2 = stepinfo(dy2, dt2);
step_info_3 = stepinfo(dy3, dt3);
step_info_4 = stepinfo(dy4, dt4);
figure(1);
clf(1);
hold on;
plot(dt1, dy1);
plot(dt2, dy2);
plot(dt3, dy3);
plot(dt4, dy4);
hold off;
grid on;
xlabel("Time (seconds)");
ylabel("Amplitude");
legend("Current control", "Real voltage control", "Naive voltage control", "Power control");