Notifications
You must be signed in to change notification settings - Fork 99
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Testserver cannot register multiple device notification #326
Comments
StefanVanDyck
changed the title
Testserver cqnnot register multiple device notification
Testserver cannot register multiple device notification
Sep 11, 2022
You are correct. Sample script showing the problem: Codeimport pyads
from pyads.testserver import AdsTestServer, AdvancedHandler, PLCVariable
from pyads import constants
from time import sleep
def main():
handler = AdvancedHandler()
test_server = AdsTestServer(handler=handler, logging=False)
test_server.start()
test_vars = [
PLCVariable(
"Test1", bytes(8), ads_type=constants.ADST_REAL64, symbol_type="LREAL"
),
PLCVariable(
"Test2", bytes(8), ads_type=constants.ADST_REAL64, symbol_type="LREAL"
),
]
for var in test_vars:
handler.add_variable(var)
sleep(1)
plc = pyads.Connection("127.0.0.1.1.1")
@plc.notification(pyads.PLCTYPE_LREAL)
def callback_1(*args):
print("Callback 1:", args)
@plc.notification(pyads.PLCTYPE_LREAL)
def callback_2(*args):
print("Callback 2:", args)
with plc:
symbols = [
plc.get_symbol("Test1"),
plc.get_symbol("Test2"),
]
symbols[0].add_device_notification(callback_1)
symbols[1].add_device_notification(callback_2)
symbols[0].write(64984.262)
symbols[1].write(-78978.855)
del symbols
sleep(1)
test_server.stop()
sleep(1)
if __name__ == "__main__":
main() Instead, This has no reference to C handles (fortunately maybe). This bit short circumvent the C library completely. I'll make a tiny PR in a minute. EDIT: #329 |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I was trying to use the test server to mock the behavior of the PLC.
Everything worked great, but I ran into some issues when using device notifications.
First I didn't realize until I started debugging the code that the:
The test server has to run in the same python process as the calling code to be able to work.
Seems like it relies on this global callback store variable to be populated by the client somehow?
Not quite sure if that's really the issue, but I just never got it to work running in a forked process or a docker container.
If this is the case, it might be useful to add some additional asterisk in the docs to make this extra clear.
Secondly, when registering multiple device notifications on different variables:
The test server reuses the same handle.
The offending line seems to me to be this one: https://github.com/stlehmann/pyads/blob/master/pyads/testserver/advanced_handler.py#L167
This will not increment handles across different PLCVariables.
Instead changing it to PLCVariable.notification_count kinda makes it work.
Unless device notifications are deleted and then the whole handle things goes out of whack anyway.
In conclusion I suppose the problem is the python code is trying to guess what the handle is the C-library will use, but that guessing is not entirely correct. Not sure how to fix that.
Might be totally wrong about this though, not really sure I understand all the stuff that's happening here.
The text was updated successfully, but these errors were encountered: