Download Docker image from :
Table of Contents
This Docker container only works on Dell PowerEdge servers that support IPMI commands, i.e. < iDRAC 9 firmware 3.30.30.30.
- Log into your iDRAC web console
- In the left side menu, expand "iDRAC settings", click "Network" then click "IPMI Settings" link at the top of the web page.
- Check the "Enable IPMI over LAN" checkbox then click "Apply" button.
- Test access to IPMI over LAN running the following commands :
apt -y install ipmitool
ipmitool -I lanplus \
-H <iDRAC IP address> \
-U <iDRAC username> \
-P <iDRAC password> \
sdr elist all
- with local iDRAC:
docker run -d \
--name Dell_iDRAC_fan_controller \
--restart=unless-stopped \
-e IDRAC_HOST=local \
-e FAN_SPEED=<decimal or hexadecimal fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \
-e CHECK_INTERVAL=<seconds between each check> \
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \
--device=/dev/ipmi0:/dev/ipmi0:rw \
tigerblue77/dell_idrac_fan_controller:latest
- with LAN iDRAC:
docker run -d \
--name Dell_iDRAC_fan_controller \
--restart=unless-stopped \
-e IDRAC_HOST=<iDRAC IP address> \
-e IDRAC_USERNAME=<iDRAC username> \
-e IDRAC_PASSWORD=<iDRAC password> \
-e FAN_SPEED=<decimal or hexadecimal fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \
-e CHECK_INTERVAL=<seconds between each check> \
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \
tigerblue77/dell_idrac_fan_controller:latest
docker-compose.yml
examples:
- to use with local iDRAC:
version: '3'
services:
Dell_iDRAC_fan_controller:
image: tigerblue77/dell_idrac_fan_controller:latest
container_name: Dell_iDRAC_fan_controller
restart: unless-stopped
environment:
- IDRAC_HOST=local
- FAN_SPEED=<decimal or hexadecimal fan speed>
- CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold>
- CHECK_INTERVAL=<seconds between each check>
- DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false>
devices:
- /dev/ipmi0:/dev/ipmi0:rw
- to use with LAN iDRAC:
version: '3'
services:
Dell_iDRAC_fan_controller:
image: tigerblue77/dell_idrac_fan_controller:latest
container_name: Dell_iDRAC_fan_controller
restart: unless-stopped
environment:
- IDRAC_HOST=<iDRAC IP address>
- IDRAC_USERNAME=<iDRAC username>
- IDRAC_PASSWORD=<iDRAC password>
- FAN_SPEED=<decimal or hexadecimal fan speed>
- CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold>
- CHECK_INTERVAL=<seconds between each check>
- DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false>
All parameters are optional as they have default values (including default iDRAC username and password).
IDRAC_HOST
parameter can be set to "local" or to your distant iDRAC's IP address. Default value is "local".IDRAC_USERNAME
parameter is only necessary if you're adressing a distant iDRAC. Default value is "root".IDRAC_PASSWORD
parameter is only necessary if you're adressing a distant iDRAC. Default value is "calvin".FAN_SPEED
parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%).CPU_TEMPERATURE_TRESHOLD
parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C).CHECK_INTERVAL
parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s).DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false.
If your server frequently switches back to the default Dell fan mode:
- Check
Tcase
(case temperature) of your CPU on Intel Ark website and then setCPU_TEMPERATURE_TRESHOLD
to a slightly lower value. Example with my CPUs (Intel Xeon E5-2630L v2) : Tcase = 63°C, I setCPU_TEMPERATURE_TRESHOLD
to 60(°C). - If it's already good, adapt your
FAN_SPEED
value to increase the airflow and thus further decrease the temperature of your CPU(s) - If neither increasing the fan speed nor increasing the threshold solves your problem, then it may be time to replace your thermal paste
Contributions are what make the open source community such an amazing place to learn, inspire, and create. Any contributions you make are greatly appreciated.
If you have a suggestion that would make this better, please fork the repo and create a pull request. You can also simply open an issue with the tag "enhancement". Don't forget to give the project a star! Thanks again!
- Fork the Project
- Create your Feature Branch (
git checkout -b feature/AmazingFeature
) - Commit your Changes (
git commit -m 'Add some AmazingFeature'
) - Push to the Branch (
git push origin feature/AmazingFeature
) - Open a Pull Request