LM75 thermometer placement #19

Open
jmatyas opened this issue Dec 22, 2023 · 0 comments
Open

LM75 thermometer placement #19

jmatyas opened this issue Dec 22, 2023 · 0 comments
Milestone

Comments

@jmatyas
Copy link

jmatyas commented Dec 22, 2023

Both LM75 thermometers are separated from RF channels and power amplifiers by radiator. Shouldn't they be placed just around the main heating element (or on the other side of the board with some kind of thermal connection to the element)?

Correct me if I'm wrong, but the way they are placed now, their measurements are meaningless - the temperature outside of the radiator is of a given value and provides no reliable way of knowing what temperature is around power amplifiers. Or am I missing something?

@kaolpr kaolpr added this to the v1.1 milestone Feb 8, 2024