Skip to content

Releases: rogerlinndesign/linnstrument-firmware

1.0.7

20 Dec 15:10
Compare
Choose a tag to compare
  • Noticeable playability improvements
  • Reimplemented velocity and pressure sensitivity modes so that the low settings have more range and all the settings have a smooth curve from 0 to 127
  • Low row now behaves exactly the same in slides as the main playing area, including quantization
  • Allow CC faders to be 'played' with multiple fingers similar to the low row
  • Performance optimizations and latency reduction
  • Improved MIDI message output speed
  • Fixed rare situation of switches being inadvertently pressed for a rectangular touch formations

1.0.6

12 Dec 15:58
Compare
Choose a tag to compare
  • Tweaks to initial touch quantization so that immediate slides feel more natural
  • Tweaks for sensor differences in November models
  • Added indicator in global settings that lights red when the LinnStrument is not calibrated and green when the calibration has been performed
  • Added support for sending and retrieving the LinnStrument calibration and settings over serial so that the firmware upgrade tool can restore everything after a firmware upgrade

1.0.5

21 Nov 22:42
Compare
Choose a tag to compare
  • Slow pitch slides now don't have any jumps anymore that were due to the 1mm groove between the cells
  • Improved the Notes Off feature, it now sends CC 120, as well as NoteOff for each note number and each channel, and Sustain Off for each channel
  • Changed 'focused cell' logic in One Channel mode, instead of doing pitch-slides and expression on the highest note, it's now on the more recent one
  • The global active split color is now displayed in split mode with the LED of the 'Split' switch
  • Double-tapping the 'Split' switch now activates the other split, similar to selecting the split in 'Per-Split Settings'
  • Pedal and switch operations apart from Alt Split, can now act upon both splits when split mode is active by pressing the cell above the Octave Dn setting
  • Fix for foot switch assignments being reversed
  • Fix for low-row bend not properly supporting multiple fingers for pitch-bend jumps anymore
  • Fix for played cell lights sticking if identical notes are played on both splits
  • Fix to reset operation so that calibration data is not lost

1.0.4

30 Oct 07:44
Compare
Choose a tag to compare
  • Slides transition smoother from one cell to another, based on the pressure contribute of each cell
  • Timbre/Y data changes are stabilized when sliding rapidly over the X axis
  • Active note lights now stay lit when the same note value in a different position is pressed and released
  • Added four additional Y calibration columns, these are needed to obtain precise and predictable timbre changes everywhere
  • Introduced easy-to-use one-click firmware updater tool
  • Automatically activate calibration procedure after a firmware update

1.0.3

29 Oct 16:57
Compare
Choose a tag to compare
  • Added low-power mode for iOS bus-power use that is selected by holding down Octave/Transpose at startup
  • Added support for independent per-split pitch and light transposition
  • Increased octave transposition range to -5 and +5
  • Made preset change slider less sensitive in the first three columns to make it easier to just go to previous/next
  • Fix for MIDI jacks selection not being persisted correctly across restarts
  • Dramatically improved detection of phantom touches, using a new algorithm that relies on calibration
  • Added advanced arbitrary CC support by using the 5th option down in the per-split Timbre/Y and Loudness/Z columns