You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When using the command YARP_FORWARD_LOG_ENABLE=1 yarprobotinterface --config ergocub.xml --enable_tags "(enable_ros2)" , the robot fails to start as there is an hardware fault on the left wrist.
Detailed context
Upon running motorgui during startup we see the hardware fault on the left wrist showing error in the encoders.
github-actionsbot
changed the title
Robot doesn't start due to left wrist hardware fault
ergoCub 1.3 S/N:002 β Robot doesn't start due to left wrist hardware fault
Sep 6, 2024
Following @AntonioConsilvio 's advice, we checked if the left wrist connectors were disconnected. With @mebbaid we made the connectionand the robot was able to start up. But one motion of the hands caused disconnection once again, as seen in the picture below.
After few tries and pushing the cable behind the parallel mechanism of the wrist to prevent it from disconnecting, we succeeded and we were able to run experiments. I shall leave the issue open for further verification and solidifying the connection.
Robot Name π€
ergoCub 1.3 S/N:002
Request/Failure description
When using the command YARP_FORWARD_LOG_ENABLE=1 yarprobotinterface --config ergocub.xml --enable_tags "(enable_ros2)" , the robot fails to start as there is an hardware fault on the left wrist.
Detailed context
Upon running motorgui during startup we see the hardware fault on the left wrist showing error in the encoders.
After a few restarts we started getting the following error as can be seen in the log.
log_ergocub-torso_yarprobotinterface_3115.txt
Additional context
No response
How does it affect you?
We are unable to perform experiments for an upcoming deadline.
The text was updated successfully, but these errors were encountered: