More devices still need to be writen in the app
- 005107 - Solar Outside Siren
- 004001 - Smoke Detector and Siren
- 009402 - 10 Year Smoke Detector and Siren
- 010101 - Thermostat Valve
- 009006 - Wall Plug Switch Indoor
- 009105 - Wall Plug Switch Outdoor
- 123580 - Dimmer 67G
- 123610 - Switch 68G
- 009204 - KFOB-C Remote Control
- 012501 - Strike Lock Control
- 700168 - Z.Rain
- 005206 - Weather - Need help some reports dont get in
- 009501 - Secure Flow Stop – Valve Shut-Off
You are welcome to help , please send in you're git pull requests to add more devices to the list.
- English
- Dutch
Most reliable way to update battery powered devices
- Place the sensor near Homey (< 1 meter)
- Change the settings to the values you want
- Wake up the sensor
- During the blinking of the LED (indicating connection to Homey) press "save settings"
If problems persists:
a. Temporarely disable other Z-wave apps
b. change the setting to another value with above steps
c. check if effective and retry to the desired value
added:
- 700168 - Z.Rain
fixed:
Corrected ProductID on Keyfob and Valve because of wrong info in PoPP documentation
Fixed typo in the double click button 3 flow card
fixed:
Typo in the valve driver that crashed the PoPP app :(
added:
009006 - Wall Plug Switch Indoor
009105 - Wall Plug Switch Outdoor
009204 - KFOB-C Remote Control
009501 - Secure Flow Stop – Valve Shut-Off
added:
009402 - 10 Year Smoke Detector and Siren
update:
Added new manufacturerId for Z-Weather, seems like PoPP doesnt even take the trouble to flash there own firmware in the rebranded stuff anymore
added:
012501 - PoPP Strike Lock Control
added:
004001 - PoPP Smoke Detector and Siren
005206 - PoPP Weather
These devices are added just by reading the documentation.
PoPP.Eu is known for its limited documantation , so please report to me if you
have one of these devices for testing.
update:
Z-Wave driver updated to 1.1.6
update:
Complete re-write of the Solar Siren only app to support more devices. Driver names changed so it matches the device id.
added:
Siren tamper and battery alarm.
Siren trigger on temperature and battery alarm.
Thermostat Valve added wakeup report for temp.
Dimmer 67G support.
Switch 68G support.
known issues:
Thermo Valve E5 errors and lost of connection / high battery usage.
Athom is working on a solution it the core for this problem.