forked from chrislgarry/Apollo-11
-
Notifications
You must be signed in to change notification settings - Fork 0
/
RCS-CSM_DIGITAL_AUTOPILOT.s
976 lines (880 loc) · 24.1 KB
/
RCS-CSM_DIGITAL_AUTOPILOT.s
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
# Copyright: Public domain.
# Filename: RCS-CSM_DIGITAL_AUTOPILOT.agc
# Purpose: Part of the source code for Colossus 2A, AKA Comanche 055.
# It is part of the source code for the Command Module's (CM)
# Apollo Guidance Computer (AGC), for Apollo 11.
# Assembler: yaYUL
# Contact: Ron Burkey <[email protected]>.
# Website: www.ibiblio.org/apollo.
# Pages: 1002-1024
# Mod history: 2009-05-13 RSB Adapted from the Colossus249/ file of the
# same name, using Comanche055 page images.
#
# This source code has been transcribed or otherwise adapted from digitized
# images of a hardcopy from the MIT Museum. The digitization was performed
# by Paul Fjeld, and arranged for by Deborah Douglas of the Museum. Many
# thanks to both. The images (with suitable reduction in storage size and
# consequent reduction in image quality as well) are available online at
# www.ibiblio.org/apollo. If for some reason you find that the images are
# illegible, contact me at [email protected] about getting access to the
# (much) higher-quality images which Paul actually created.
#
# Notations on the hardcopy document read, in part:
#
# Assemble revision 055 of AGC program Comanche by NASA
# 2021113-051. 10:28 APR. 1, 1969
#
# This AGC program shall also be referred to as
# Colossus 2A
# Page 1002
# T5 INTERRUPT PROGRAM FOR THE RCS-CSM AUTOPILOT
# START OF T5 INTERRUPT PROGRAM
BANK 20
SETLOC DAPS3
BANK
COUNT 21/DAPRC
EBANK= KMPAC
REDORCS LXCH BANKRUPT # RESTART OF AUTOPILOT COMES HERE
CA T5PHASE # ON A T5 RUPT
EXTEND
BZMF +2 # IF T5PHASE +0, -0, OR -, RESET TO -
TCF +3 # IF T5PHASE +, LEAVE IT +. DO A FRESHDAP
CS ONE
TS T5PHASE
EXTEND
DCA RCSLOC
DXCH T5LOC # HOOK UP T5RUPT TO AUTOPILOT
TCF RCSATT +1
EBANK= KMPAC
RCSLOC 2CADR RCSATT
RCSATT LXCH BANKRUPT # SAVE BB
EXTEND # SAVE Q
QXCH QRUPT
CAF BIT15 # BIT15 CHAN31 = 0 IF IMU POWER IS ON AND
EXTEND # S/C CONT SW IS IN CMC (I.E., IF G/C AUTO
RAND CHAN31 # PILOT IS FULLY ENABLED)
EXTEND
BZF SETT5 # IF G/C AUTOPILOT IS FULLY ENABLED,
# GO TO SETT5
CS RCSFLAGS # IF G/C AUTOPILOT IS NOT FULLY ENABLED,
MASK BIT14
ADS RCSFLAGS # SET NORATE FLAG,
CAF POSMAX
TS HOLDFLAG # SET HOLDFLAG +,
CAF ZERO # ZERO ERRORX, ERRORY, AND ERRORZ,
TS ERRORX
TS ERRORY
TS ERRORZ
CAF BIT14
EXTEND
RAND CHAN31 # AND CHECK FREE FUNCTION (BIT14 CHAN31).
EXTEND
# Page 1003
BZF SETT5 # IF IN FREE MODE, GO TO SETT5.
TS T5PHASE # IF NOT IN FREE MODE,
CAF OCT37766 # SCHEDULE REINITIALIZATION (FRESHDAP)
TS TIME5 # IN 100 MS VIA T5RUPT
TCR ZEROJET # ZERO JET CHANNELS IN 14 MS VIA ZEROJET
TCF KMATRIX
DELTATT OCT 37770 # 80MS (TIME5)
DELTATT2 OCT 37776 # 20MS (TIME5)
ONESEK DEC 16284 # 1 SEC(TIME5)
CHAN5 EQUALS 5
CHAN6 EQUALS 6
PRIO34A = PRIO34
# CHECK PHASE OF T5 PROGRAM
#
# BECAUSE OF THE LENGTH OF THE T5 PROGRAM,IT HAS BEEN DIVIDED INTO
# THREE PARTS, T5PHASE1, T5PHASE2, AND THE JET SELECTION LOGIC,
# TO ALLOW FOR THE EXECUTION OF OTHER
# INTERRUPTS. T5PHASE IS ALSO USED IN THE INITIALIZATION OF THE AUTOPILOT
# VARIABLES AT TURN ON.
#
# THE CODING OF T5PHASE IS...
#
# + = INITIALIZE T5 RCS-CSM AUTOPILOT
# T5PHASE = +0 = PHASE2 OF THE T5 PROGRAM
# - = RESTART DAP
# -0 = PHASE1 OF THE T5 PROGRAM
SETT5 CCS T5PHASE
TCF FRESHDAP # TURN ON AUTOPILOT
TCF T5PHASE2 # BRANCH TO PHASE2 OF PROGRAM
TCF REDAP # RESTART AUTOPILOT
TS T5PHASE # PHASE 1 RESET FOR PHASE 2
CA TIME5
TS T5TIME # USED IN COMPENSATING FOR DELAYS IN T5
CAF DELTATT2 # RESET FOR T5RUPT IN 20MS FOR PHASE2
TS TIME5 # OF PROGRAM
# Page 1004
# IMU STATUS CHECK
CS IMODES33 # CHECK IMU STATUS
MASK BIT6 # BIT6 = 0 IMU OK
CCS A # BIT6 = 1 NO IMU
TCF RATEFILT
FREECHK CS RCSFLAGS # BIT14 INDICATES THAT RATES HAVE NOT BEEN
MASK BIT14 # INITIALIZED
ADS RCSFLAGS
CAF BIT14 # NO ATTITUDE REFERENCE
TS HOLDFLAG # STOP ANY AUTOMATIC STEERING AND PREPARE
# TO PICK UP CDU ANGLES UPON RESUMPTION OF
# ATTITUDE HOLD
EXTEND
RAND CHAN31 # CHECK FOR FREE MODE
EXTEND
BZF KRESUME1 # IN FREE MODE PROVIDE FREE CONTROL ONLY
TCF REINIT # .....TILT...............................
BITS4,5 OCT 30
RATEFILT CA RCSFLAGS # SEE IF RATEFILTER HAS BEEN INITIALIZED
MASK BIT14
EXTEND # IF SO, PROCEED WITH RATE DERIVATION
BZF +2
TCF KMATRIX # IF NOT, SKIP RATE DERIVATION
# RATE FILTER TIMING = 7.72 MS
#
# RATE FILTER EQUATIONS
#
#
# DRHO = DELRHO - (.1)ADOT + (1 = GAIN1)DRHO
# -1
#
# ADOT = ADOT + GAIN2 DRHO + KMJ DFT
# -1
# _ * _ _
# WHERE DELRHO = AMGB (CDU - CDU )
# -1
CAF TWO
DRHOLOOP TS SPNDX
DOUBLE
TS DPNDX
INDEX DPNDX
CS DRHO # DRHO SCALED 180 DEGS
EXTEND
INDEX ATTKALMN # PICK UP DESIRED FILTER GAIN
MP GAIN1
INDEX DPNDX
DAS DRHO # (1 -.064) DRHO
EXTEND
# Page 1005
INDEX DPNDX
DCS ADOT
DXCH KMPAC # -(.1)ADOT
CA QUARTER
TC SMALLMP
DXCH KMPAC
INDEX DPNDX
DAS DRHO
CCS SPNDX
TCF DRHOLOOP
CA CDUX # MEASURED BODY RATES--
XCH RHO
EXTEND
MSU RHO # _ * _ _
COM # DELRHO = AMGB (CDU - CDU )
# -1
ZL
DXCH DELTEMPX
CA CDUY
XCH RHO1
EXTEND
MSU RHO1
COM
TS T5TEMP # (CDUY - RHO1) SCALED 90 DEGS
EXTEND
MP AMGB1
DAS DELTEMPX # DELTEMPX = (CDUX-RHO) + AMGB1(CDUY-RHO1)
# MUST BE DOUBLE PRECISION OR WILL LOSE
# PULSES
CA AMGB4
EXTEND
MP T5TEMP
DXCH DELTEMPY
CA AMGB7
EXTEND
MP T5TEMP
DXCH DELTEMPZ
CA CDUZ
XCH RHO2
EXTEND
MSU RHO2
COM
TS T5TEMP # (CDUZ - RHO2) SCALED 90 DEGS
EXTEND
MP AMGB5
DAS DELTEMPY # DELTEMPY = AMGB4(CDUY-RHO1)
# + AMGB5(CDUZ-RHO2)
CA AMGB8
EXTEND
# Page 1006
MP T5TEMP
DAS DELTEMPZ # DELTEMPZ = AMBG7(CDUY-RHO1)
# + AMGB8(CDUZ-RHO2)
CAF TWO
ADOTLOOP TS SPNDX
DOUBLE
TS DPNDX
EXTEND
INDEX DPNDX
DCA DELTEMPX
INDEX DPNDX
DAS DRHO
EXTEND
INDEX DPNDX
DCA DELTEMPX
INDEX DPNDX
DAS MERRORX
INDEX DPNDX
CA DRHO
DOUBLE # N.B.
DOUBLE # N.B.
EXTEND
INDEX ATTKALMN # PICK UP DESIRED FILTER GAINS
MP GAIN2
INDEX DPNDX # ADOT + (.16)(.1)DRHO
DAS ADOT # -1
INDEX SPNDX # S/C TORQUE TO INERTIA RATIO
CA KMJ # SCALED (450)(1600)/(57.3)(16384)=1/1.3
EXTEND
INDEX SPNDX
MP DFT
INDEX DPNDX
DAS ADOT # KMJ(DFT)
CCS SPNDX
TCF ADOTLOOP # END CALCULATION OF VEHICLE RATES
KMATRIX CA ATTSEC
MASK LOW4
CCS A
TCF TENTHSEK
CAF PRIO34 # CALL FOR 1 SEC UPDATE OF TRANSFORMATION
TC NOVAC # MATRIX FROM GIMBAL AXES TO BODY AXES
EBANK= KMPAC
2CADR AMBGUPDT
CAF NINE
TENTHSEK TS ATTSEC
# Page 1007
# WHEN AUTOMATIC MANEUVERS ARE BEING PERFORMED, THE FOLLOWING ANGLE ADDITION MUST BE MADE TO PROVIDE A SMOOTH
# SEQUENCE OF ANGULAR COMMANDS TO THE AUTOPILOT--
#
# CDUXD = CDUXD + DELCDUX (DOUBLE PRECISION)
# CDUYD = CDUYD + DELCDUY (DOUBLE PRECISION)
# CDUZD = CDUZD + DELCDUZ (DOUBLE PRECISION)
#
# THE STEERING PROGRAMS:
# 1) ATTITUDE MANEUVER ROUTINE
# 2) LEM TRACKING
#
# SHOULD GENERATE THE DESIRED ANGLES (CDUXD, CDUYD, CDUZD) AS WELL AS THE INCREMENTAL ANGLES (DELCDUX, DELCDUY,
# DELCDUZ) SO THAT THE GIMBAL ANGLE COMMANDS CAN BE INTERPOLATED BETWEEN UPDATES.
#
# HOLDFLAG CODING:
#
# + = GRAB PRESENT CDU ANGLES AND STORE IN THETADX, THETADY, THETADZ
# AND PERFORM ATTITUDE HOLD ABOUT THESE ANGLES
# ALSO IGNORE AUTOMATIC STEERING
# SET = + BY
# 1) INITIALIZATION PHASE OF AUTOPILOT
# 2) OCCURANCE OF RHC COMMANDS
# 3) FREE MODE
# 4) SWITCH OVER TO ATTITUDE HOLD FROM AUTO
# WHILE DOING AUTOMATIC STEERING (IN THIS CASE
# HOLDFLAG IS NOT ACTUALLY SET TO +, BUT THE LOGIC
# FUNCTIONS AS IF IT WERE.)
# 5) S/C CONTROL SWITCH IS SCS
# 6) IMU POWER OFF
# +0 = IN ATTITUDE HOLD ABOUT A PREVIOUSLY ESTABLISHED REFERENCE
# - = PERFORMING AUTOMATIC MANEUVER
# -0 = NOT USED AT PRESENT
#
# NOTE THAT THIS FLAG MUST BE SET = - BY THE STEERING PROGRAM IF IT IS TO COMMAND THE AUTOPILOT.
# SINCE ASTRONAUT ACTION MAY CHANGE THE HOLDFLAG SETTING, IT SHOULD BE MONITORED BY THE STEERING PROGRAM TO
# DETERMINE IF THE AUTOMATIC SEQUENCE HAS BEEN INTERRUPTED AND IF SO, TAKE THE APPROPRIATE ACTION.
CS HOLDFLAG
EXTEND
BZMF DACNDLS # IF HOLDFLAG +0,-0,+, BYPASS AUTOMATIC
# COMMANDS.
DCDUINCR CAF TWO
DELOOP TS SPNDX
DOUBLE
TS DPNDX
EXTEND
INDEX A
DCA CDUXD
# Page 1008
DXCH KMPAC
EXTEND
INDEX DPNDX
DCA DELCDUX
TC DPADD
EXTEND
DCA KMPAC
INDEX SPNDX
TS THETADX
INDEX DPNDX
DXCH CDUXD
CCS SPNDX
TCF DELOOP
# Page 1009
# RCS-CSM AUTOPILOT ATTITUDE ERROR DISPLAY
#
# THREE TYPES OF ATTITUDE ERRORS MAY BE DISPLAYED ON THE FDAI:
#
# MODE 1) AUTOPILOT FOLLOWING ERRORS SELECTED BY V61E
# GENERATED INTERNALLY BY THE AUTOPILOT
#
# MODE 2) TOTAL ATTITUDE ERRORS SELECTED BY V62E
# WITH RESPECT TO THE CONTENTS OF N22
#
# MODE 3) TOTAL ASTRONAUT ATTITUDE ERRORS SELECTED BY V63E
# WITH RESPECT TO THE CONTENTS OF N17
#
# MODE 1 IS PROVIDED AS A MONITOR OF THE RCS DAP AND ITS ABILITY TO TRACK AUTOMATIC STEERING COMMANDS. IN THIS
# MODE THE ATTITUDE ERRORS WILL BE ZEROED WHEN THE CMC MODE SWITCH IS IN FREE.
#
# MODE 2 IS PROVIDED TO ASSIST THE CREW IN MANUALLY MANEUVERING THE S/C TO THE ATTITUDE (GIMBAL ANGLES) SPECIFIED
# IN N22. THE ATTITUDE ERRORS WRT THESE ANGLES AND THE CURRENT CDU ANGLES ARE RESOLVED INTO S/C CONTROL AXES
# AS A FLY-TO INDICATOR.
#
# MODE 3 IS PROVIDED TO ASSIST THE CREW IN MANUALLY MANEUVERING THE S/C TO THE ATTITUDE (GIMBAL ANGLES) SPECIFIED
# IN N17. THE ATTITUDE ERRORS WRT THESE ANGLES AND THE CURRENT CDU ANGLES ARE RESOLVED INTO S/C CONTROL AXES
# AS A FLY-TO INDICATOR.
#
# V60 IS PROVIDED TO LOAD N17 WITH A SNAPSHOT OF THE CURRENT CDU ANGLES, THUS SYNCHRONIZING THE MODE 3 DISPLAY
# WITH THE CURRENT S/C ATTITUDE. THIS VERB MAY BE USED AT ANY TIME.
#
# THESE DISPLAYS WILL BE AVAILABLE IN ANY MODE (AUTO, HOLD, FREE, G+N, OR SCS) ONCE THE RCS DAP HAS BEEN
# INITIATED VIA V46E. MODE 1, HOWEVER, WILL BE MEANINGFUL ONLY IN G+N AUTO OR HOLD. THE CREW MAY PRESET (VIA
# V25N17) AN ATTITUDE REFERENCE (DESIRED GIMBAL ANGLES) INTO N17 AT ANY TIME.
DACNDLS CS RCSFLAGS # ALTERNATE BETWEEN FDAIDSP1 AND FDAIDSP2
MASK BIT4
EXTEND
BZF FDAIDSP2
FDAIDSP1 ADS RCSFLAGS
TC NEEDLER
KRESUME1 TCF RESUME # END PHASE 1
# Page 1010
# FDAI ATTITUDE ERROR DISPLAY SUBROUTINE
#
# PROGRAM DESCRIPTION: D. KEENE 5/24/67
#
# THIS SUBROUTINE IS USED TO DISPLAY ATTITUDE ERRORS ON THE FDAI VIA THE DIGITAL TO ANALOG CONVERTERS (DACS)
# IN THE CDUS. CARE IS TAKEN TO METER OUT THE APPROPRIATE NUMBER OF PULSES TO THE IMU ERROR COUNTERS AND PREVENT
# OVERFLOW, TO CONTROL THE RELAY SEQUENCING, AND TO AVOID INTERFERENCE WITH THE COARSE ALIGN LOOP WHICH ALSO USES
# THE DACS.
#
# CALLING SEQUENCE:
#
# DURING THE INITIALIZATION SECTION OF THE USER'S PROGRAM, BIT3 OF RCSFLAGS SHOULD BE SET TO INITIATE THE
# TURN-ON SEQUENCE WITHIN THE NEEDLES PROGRAM:
#
# CS RCSFLAGS # IN EBANK6
# MASK BIT3
# ADS RCSFLAGS
#
# THEREAFTER, THE ATTITUDE ERRORS GENERATED BY THE USER SHOULD BE TRANFERRED TO THE FOLLOWING LOCATIONS IN EBANK6:
#
# AK SCALED 180 DEGREES NOTE: THESE LOCATIONS ARE SUBJECT
# AK1 SCALED 180 DEGREES TO CHANGE
# AK2 SCALED 180 DEGREES
#
# FULL SCALED DEFLECTION CORRESPONDS TO 16 7/8 DEGREES OF ATTITUDE ERROR
# (= 384 BITS IN IMU ERROR COUNTER)
#
# A CALL TO NEEDLER WILL THEN UPDATE THE DISPLAY:
#
# INHINT
# TC IBNKCALL # NOTE: EBANK SHOULD BE SET TO E6
# CADR NEEDLER
# RELINT
#
# THIS PROCESS SHOULD BE REPEATED EACH TIME THE ERRORS ARE UPDATED. AT LEAST 3 PASSES THRU THE PRORAM ARE
# REQUIRED BEFORE ANYTHING IS ACTUALLY DISPLAYED ON THE ERROR METERS.
# NOTE: EACH CALL TO NEEDLER MUST BE SEPARATED BY AT LEAST 50MS TO ASSURE PROPER RELAY SEQUENCING.
#
# ERASABLE USED:
# AK CDUXCMD
# AK1 CDUYCMD
# AK2 CDUZCMD
# EDRIVEX A,L,Q
# EDRIVEY T5TEMP
# EDRIVEZ SPNDX
#
# SWITCHES; RCSFLAGS BITS 3,2
#
# I/O CHANNELS: CHAN12 BIT 4 (COARSE ALIGN - READ ONLY)
# Page 1011
# CHAN12 BIT 6 (IMU ERROR COUNTER ENABLE)
# CHAN14 BIT 13,14,15 (DAC ACTIVITY)
#
# SIGN CONVENTION: AK = THETAC - THETA
# WHERE THETAC = COMMAND ANGLE
# THETA = PRESENT ANGLE
NEEDLER CAF BIT4 # CHECK FOR COARSE ALIGN ENABLE
EXTEND # IF IN COARSE ALIGN DO NOT USE IMU
RAND CHAN12 # ERROR COUNTERS. DON'T USE NEEDLES
EXTEND
BZF NEEDLER1
CS RCSFLAGS # SET BIT3 FOR INITIALIZATION PASS
MASK BIT3
ADS RCSFLAGS
TC Q
NEEDLER1 CA RCSFLAGS
MASK SIX
EXTEND
BZF NEEDLES3
MASK BIT3
EXTEND
BZF NEEDLER2 # BIT3 = 0, BIT2 = 1
CS BIT6 # FIRST PASS BIT3 = 1
EXTEND # DISABLE IMU ERROR COUNTER TO ZERO DACS
WAND CHAN12 # MUST WAIT AT LEAST 60 MS. BEFORE
NEEDLE11 CS ZERO # ENABLING COUNTERS.
TS AK # ZERO THE INPUTS ON FIRST PASS
TS AK1
TS AK2
TS EDRIVEX # ZERO THE DISPLAY REGISTERS
TS EDRIVEY
TS EDRIVEZ
TS CDUXCMD # ZERO THE OUT COUNTERS
TS CDUYCMD
TS CDUZCMD
CS SIX # RESET RCSFLAGS FOR PASS2
MASK RCSFLAGS
AD BIT2
TS RCSFLAGS
TC Q # END PASS1
NEEDLER2 CAF BIT6 # ENABLE IMU ERROR COUNTERS
EXTEND
WOR CHAN12
CS SIX # RESET RCSFLAGS TO DISPLAY ATTITUDE
# Page 1012
MASK RCSFLAGS # ERRORS WAIT AT LEAST 4 MS FOR
TS RCSFLAGS # RELAY CLOSURE
TC Q
NEEDLES3 CAF BIT6 # CHECK TO SEE IF IMU ERROR COUNTER
EXTEND # IS ENABLED
RAND CHAN12
EXTEND # IF NOT RECYCLE NEEDLES
BZF NEEDLER +5
NEEDLES CAF TWO
DACLOOP TS SPNDX
CS QUARTER
EXTEND
INDEX SPNDX
MP AK
TS L
CCS A
CA DACLIMIT
TCF +2
CS DACLIMIT
AD L
TS T5TEMP # OVFLO CHK
TCF +4
INDEX A # ON OVERFLOW LIMIT OUTPUT TO +-384
CAF DACLIMIT
TS L
INDEX SPNDX
CS EDRIVEX # CURRENT VALUE OF DAC
AD L
INDEX SPNDX
ADS CDUXCMD
INDEX SPNDX
LXCH EDRIVEX
CCS SPNDX
TCF DACLOOP
CAF 13,14,15
EXTEND
WOR CHAN14 # SET DAC ACTIVITY BITS
TC Q
REINIT CAF DELAY200 # ........TILT LOGIC
TS TIME5 # REINITIALIZE DAP IN 200MS
TS T5PHASE
TCF RESUME
DELAY200 DEC 16364 # 200MS
DEC -384
# Page 1013
DACLIMIT DEC 16000
DEC 384
# Page 1014
# INITIALIZATION PROGRAM FOR RCS-CSM AUTOPILOT
#
# THE FOLLOWING QUANTITIES WILL BE ZEROED AND SHOULD APPEAR IN CONSECUTIVE LOCATIONS IN MEMORY AFTER WBODY
#
# WBODY (+1) DFT TAU2
# WBODY1 (+1) DFT1 BIAS
# WBODY2 (+1) DFT2 BIAS1
# ADOT (+1) DRHO (+1) BIAS2
# ADOT1 (+1) DRHO1 (+1) ERRORX
# ADOT2 (+1) DRHO2 (+1) ERRORY
# MERRORX (+1) ATTSEC ERRORZ
# MERRORY (+1) TAU
# MERRORZ (+1) TAU1
FRESHDAP CAF ONE # RESET HOLDFLAG TO STOP AUTOMATIC
TS HOLDFLAG # STEERING AND PREPARE TO PICK UP AN
# ATTITUDE HOLD REFERENCE
REDAP TC IBNKCALL # DECODE DAPDATR1, DAPDATR2 FOR DEADBANDS
CADR S41.2 # RATES, QUADFAILS, QUAD MANAGEMENT
TC IBNKCALL # DECODE IXX, IAVG, AND CONVERT
CADR S40.14 # TO AUTOPILOT GAINS
CAF NO.T5VAR # NO. LOCATIONS TO BE ZEROED MINUS ONE
ZEROT5 TS SPNDX # ZERO ALL NECESSARY ERASABLE REGISTERS
CAF ZERO
INDEX SPNDX
TS WBODY
CCS SPNDX
TCF ZEROT5
TCR ZEROJET
CS ZERO
TS CHANTEMP # INITIALIZE MINIMUM IMPULSE CONTROL
TS CH31TEMP # INITIALIZE RHC POSITION MEMORY FOR
# MANUAL RATE MODES
CAF =.24
TS SLOPE # INITIALIZE SWITCHING LOGIC SLOPE
CAF FOUR
TS T5TIME # PHASE 0 RESETS FOR PHASE 2 INTERRUPT IN
# 60 MS. PHASE 2 RESETS FOR PHASE 1 RUPT
# IN (80MS - T5TIME(40MS)). THEREFORE
# PHASE 1 (RATEFILTER) BEGINS CYCLING 100
# MS FROM NOW AND EVERY 100MS THEREAFTER.
CAF ELEVEN
TS ATTKALMN # RESET TO PICK UP KALMAN FILTER TAINS
# TO INITIALIZE THE S/C ANGULAR RATES
# Page 1015
CA CDUX
TS RHO
CA CDUY
TS RHO1
CA CDUZ
TS RHO2
CAF ZERO # RESET AUTOPILOT TO BEGIN EXECUTING
TS T5PHASE # PHASE2 OF PROGRAM
CS IMODES33 # CHECK IMU STATUS
MASK BIT6 # IF BIT6 = 0 IMU IN FINE ALIGN
CCS A # IF BIT6 = 1 IMU NOT READY
TCF IMUAOK
TS ATTKALMN # CANNOT USE IMU
CAF RCSINITB # PROVIDE FREE CONTROL ONLY
TCF RCSSWIT # DON'T START UP RATE FILTER
# SIGNAL NO RATE FILTER
IMUAOK CAF PRIO34 # START MATRIX INITIALIZATION
TC NOVAC # BYPASS IF IMU NOT IN FINE ALIGN
EBANK= KMPAC
2CADR AMBGUPDT
CAF RCSINIT # CLEAR BIT14 --ASSUME WE HAVE A GOOD IMU
RCSSWIT TS RCSFLAGS # CLEAR BIT1 --INITIALIZE T6 PROGRAM
# SET BIT3 --INITIALIZE NEEDLES
# CLEAR BIT4 --RESET FOR FDAIDSP1
CAF T5WAIT60 # NEXT T5RUPT 60 MS FROM NOW TO ALLOW IMU
# ERROR COUNTER TO ZERO.
# (MINIMUM DELAY = 15 MS)
TS TIME5 # SINCE ATTKALMN IS +11, PROGRAM WILL THEN
TC RESUME # PICK UP THE KALMAN FILTER GAINS. RATE
# FILTER WILL BEGIN OPERATING ZOOMS FROM
# NOW
# CONSTANTS USED IN INITIALIZATION PROGRAM
NO.T5VAR DEC 36
=.24 DEC .24 # = SLOPE OF 0.6/SEC
RCSINIT OCT 00004
RCSINITB OCT 20004
T5WAIT60 DEC 16378 # = 6 CS
EBANK= KMPAC
T6ADDR 2CADR T6START
ZEROJET CAF ELEVEN # ZERO BLAST2, BLAST1, BLAST, YWORD2,
TS SPNDX # YWORD1, PWORD2, PWORD1, RWORD2,
CAF ZERO # AND RWORD1
# Page 1016
INDEX SPNDX
TS RWORD1
CCS SPNDX
TCF ZEROJET +1
CAF FOUR
TS BLAST1 +1
CAF ELEVEN
TS BLAST2 +1
CS BIT1
MASK RCSFLAGS
TS RCSFLAGS # RESET BIT1 OF RCSFLAGS TO 0
EXTEND
DCA T6ADDR
DXCH T6LOC
CAF =+14MS # ENABLE T6RUPT TO SHUT OFF JETS IN 14 MS.
TS TIME6
CAF BIT15
EXTEND
WOR CHAN13
TC Q
T5PHASE2 CCS ATTKALMN # IF (+) INITIALIZE RATE ESTIMATE
TCF KALUPDT
TCF +2 # ONLY IF ATTKALMN POSITIVE
TCF +1
CA DELTATT2 # RESET FOR PHASE3 IN 20 MS
XCH TIME5 # (JET SELECTION LOGIC)
ADS T5TIME # TO COMPENSATE FOR DELAYS IN T5RUPT
CA RCSFLAGS # IF A HIGH RATE AUTO MANEUVER IS IN
MASK BIT15 # PROGRESS (BIT 15 OF RCSFLAGS SET), SET
EXTEND # ATTKALMN TO -1
BZF NOHIAUTO # OTHERWISE SET ATTKALMN TO 0.
CS ONE
NOHIAUTO TS ATTKALMN
# Page 1017
# MANUAL ROTATION COMMANDS
CS OCT01760 # RESET FORCED FIRING BITS (BITS 10 TO 5
MASK RCSFLAGS # OF RCSFLAGS) TO ZERO
TS RCSFLAGS
EXTEND
READ CHAN31
TS L
CA CH31TEMP
EXTEND
RXOR LCHAN
MASK MANROT # = OCT00077
EXTEND
BZMF NOCHANGE
LXCH A
TS CH31TEMP # SAVE CONTENTS OF CHANNEL 31 IN CH31TEMP
CA L
EXTEND
MP BIT5 # PUT BITS 6-1 OF A IN BITS 10-5 OF L
CA L
ADS RCSFLAGS # SET FORCED FIRING BITS FOR AXES WITH
# CHANGES IN COMMAND. BITS 10,9 FOR
# ROLL, BITS 8,7 FOR YAW, BITS 6,5 FOR
# PITCH
CS RCSFLAGS # SET RATE DAMPING FLAGS (BITS 13,12, AND
MASK OCT16000 # 11 OF RCSFLAGS)
ADS RCSFLAGS
NOCHANGE CS CH31TEMP
MASK MANROT
EXTEND
BZMF AHFNOROT # IF NO MANUAL COMMANDS, GO TO AHFNOROT
TS HOLDFLAG # SET HOLDFLAG +
TC STICKCHK # WHEN THE RHC IS OUT OF DETENT, PMANNDX,
# YMANNDX, AND RMANNDX ARE ALL SET, BY
# MEANS OF STICKCHK, TO 0, 1, OR 2 FOR NO,
# +, OR - ROTATION RESPECTIVELY AS
# COMMANDED BY THE RHC.
#
# HOWEVER, IT IS WELL TO NOTE THAT AFTER
# THE RHC IS RETURNED TO DETENT, THE
# PROGRAM BRANCHES TO AHFNOROT AND AVOIDS
# STICKCHK SO PMANNDX, YMANNDX, AND
# RMANNDX ARE NOT RESET TO ZERO BUT RATHER
# LEFT SET TO THEIR LAST OUT OF DETENT
# Page 1018
# VALUES.
CS FLAGWRD1 # SET STIKFLAG TO INFORM STEERING
MASK BIT14 # PROGRAMS (P20) THAT ASTRONAUT HAS
ADS FLAGWRD1 # ASSUMED ROTATIONAL CONTROL OF SPACECRAFT
CAF BIT14
EXTEND
RAND CHAN31
EXTEND
BZMF FREEFUNC
CA RCSFLAGS # EXAMINE RCSFLAGS TO SEE IF RATE FILTER
MASK BIT14 # HAS BEEN INITIALIZED
CCS A # IF SO, PROCEED WITH MANUAL RATE COMMANDS
TCF REINIT # .....TILT, RECYCLE TO INITIALIZE FILTER
CS FIVE # IF MANUAL MANEUVER IS AT HIGH RTE, SET
AD RATEINDX # ATTKALMN TO -1.
EXTEND # OTHERWISE, LEAVE ATTKALMN ALONE.
BZMF +3
CS ONE
TS ATTKALMN
CAF TWO # AUTO-HOLD MANUAL ROTATION
SETWBODY TS SPNDX
DOUBLE
TS DPNDX
INDEX SPNDX # RMANNDX = 0 NO ROTATION
CA RMANNDX # = 1 + ROTATION
EXTEND # = 2 - ROTATION
BZF NORATE # IF NO ROTATION COMMAND ON THIS AXIS,
# GO TO NORATE.
AD RATEINDX # RATEINDX = 0 0.05 DEG/SEC
TS Q # = 2 0.2 DEG/SEC
INDEX Q # = 4 0.5 DEG/SEC
CA MANTABLE -1 # = 6 2.0 DEG/SEC
EXTEND
MP BIT9 # MULTIPLY MANTABLE BY 2 TO THE -6
INDEX DPNDX # TO GET COMMANDED RATE.
DXCH WBODY # SET WBODY TO COMMANDED RATE.
CA RCSFLAGS
MASK OCT16000 # IS RATE DAMPING COMPLETED (BITS 13,12 AND
EXTEND # 11 OF RCSFLAGS ALL ZERO.) IF SO, GO TO
BZF MERUPDAT # MERUPDAT TO UPDATE CUMULATIVE ATTITUDE
# ERROR.
# Page 1019
ZEROER CA ZERO # ZEROER ZEROS MERRORS
ZL
INDEX DPNDX
DXCH MERRORX
TCF SPNDXCHK
NORATE ZL
INDEX DPNDX
DXCH WBODY # ZERO WBODY FOR THIS AXIS
CA RCSFLAGS
MASK OCT16000
EXTEND # IS RATE DAMPING COMPLETED
BZF SPNDXCHK # YES, KEEP CURRENT MERRORX GO TO SPNDXCHK
TCF ZEROER # NO, GO TO ZEROER
MERUPDAT INDEX Q # MERRORX=MERRORX+MEASURED CHANGE IN ANGLE
CS MANTABLE -1 # -COMMANDED CHANGE IN ANGLE
EXTEND # THE ADDITION OF MEASURED CHANGE IN ANGLE
MP BIT7 # HAS ALREADY BEEN DONE IN THE RATE FILTER
INDEX DPNDX # COMMANDED CHANGE IN ANGLE = WBODY TIMES
DAS MERRORX # .1SEC = MANTABLE ENTRY TIMES 2 TO THE -8
SPNDXCHK INDEX DPNDX
CA MERRORX
INDEX SPNDX
TS ERRORX # ERRORX = HIGH ORDER WORD OF MERRORX
CCS SPNDX
TCF SETWBODY
TCF JETS
OCT01760 OCT 01760 # FORCED FIRING BITS MASK
OCT01400 OCT 01400 # ROLL FORCED FIRING MASK ORDER OF
OCT00060 OCT 00060 # PITCH FORCED FIRING MASK DEFINITION
OCT00300 OCT 00300 # YAW FORCED FIRING MASK MUST BE
# PRESERVED
# FOR INDEXING
MANROT OCT 77
OCT16000 OCT 16000 # RATE DAMPING FLAGS MASK
MANTABLE DEC .0071111
DEC -.0071111
DEC .028444
DEC -0.028444
DEC .071111
DEC -.071111
DEC .284444
DEC -.284444
=+14MS DEC 23
FREEFUNC INDEX RMANNDX # ACCELERATION
# Page 1020
CA FREETAU # COMMANDS
TS TAU
INDEX PMANNDX
CA FREETAU # FREETAU 0 SEC
TS TAU1 # +1 +0.10 SEC
INDEX YMANNDX # +2 -0.10 SEC
CA FREETAU # (+3) 0 SEC
TS TAU2
TCF T6PROGM
FREETAU DEC 0
DEC 480
DEC -480
DEC 0
T6PROGM CAF ZERO # FOR MANUAL ROTATIONS
TS ERRORX
TS ERRORY
TS ERRORZ
TCF T6PROG
# Page 1021
DEC .2112 # FILTER GAIN FOR TRANSLATION, LEM ON
DEC .8400 # FILTER GAIN FOR TRANSLATION 2(ZETA)WN DT
DEC .2112 # FILTER GAIN FOR 4 DEGREE/SEC MANEUVERS
GAIN1 DEC .0640 # KALMAN FILTER GAINS FOR INITIALIZATION
DEC .3180 # OF ATTITUDE RATES
DEC .3452
DEC .3774
DEC .4161
DEC .4634
DEC .5223
DEC .5970
DEC .6933
DEC .8151
DEC .9342
DEC .0174 # FILTER GAIN FOR TRANSLATION, LEM ON
DEC .3600 # FILTER GAIN FOR TRANSLATION (WN)(WN)DT
DEC .0174 # FILTER GAIN FOR 4 DEGREE/SEC MANEUVERS
GAIN2 DEC .0016 # SCALED 10
DEC .0454
DEC .0545
DEC .0666
DEC .0832
DEC .1069
DEC .1422
DEC .1985
DEC .2955
DEC .4817
DEC .8683
STICKCHK TS T5TEMP
MASK THREE # INDICES FOR MANUAL ROTATION
TS PMANNDX
CA T5TEMP
EXTEND # MAN RATE 0 0 RATE (DP)
MP QUARTER # +1 + RATE (DP)
TS T5TEMP # +2 - RATE (DP)
MASK THREE # (+3) 0 RATE (DP)
TS YMANNDX
CA T5TEMP
EXTEND
MP QUARTER
TS RMANNDX
TC Q
KALUPDT TS ATTKALMN # INITIALIZATION OF ATTITUDE RATES USING
# KALMAN FILTER TAKES 1.1 SEC
CA DELTATT # =1SEC - 80MS
AD T5TIME # + DELAYS
# Page 1022
TS TIME5
TCF +3
CAF DELTATT2 # SAFETY PLAY TO ASSURE
TS TIME5 # A T5RUPT
KRESUME2 CS ZERO # RESET FOR PHASE1
TS T5PHASE # RESUME INTERRUPTED PROGRAM
TCF RESUME
FDAIDSP2 CS BIT4 # RESET FOR FDAIDSP1
MASK RCSFLAGS
TS RCSFLAGS
CS FLAGWRD0 # ON - DISPLAY ONE OF THE TOTAL ATTITUDE
MASK BIT9 # ERRORS
EXTEND
BZF FDAITOTL
EXTEND
DCS ERRORX # OFF - DISPLAY AUTOPILOT FOLLOWING ERROR
DXCH AK
CS ERRORZ
TS AK2
TCF RESUME # END PHASE 1
FDAITOTL CA FLAGWRD9
MASK BIT6
EXTEND
BZF WRTN17 # IS N22ORN17 (BIT6 OF FLAGWRD9) = 0
# IF SO, GO TO WRTN17
WRTN22 EXTEND # OTHERWISE, CONTINUE ON TO WRTN22 AND
DCA CTHETA # GET SET TO COMPUTE TOTAL ATTITUDE
DXCH WTEMP # ERROR WRT N22 BY PICKING UP THE THREE
CA CPHI # COMPONENTS OF N22
GETAKS EXTEND # COMPUTE TOTAL ATTITUDE ERROR FOR
MSU CDUX # DISPLAY ON FDAI ERROR NEEDLES
TS AK
CA WTEMP
EXTEND
MSU CDUY
TS T5TEMP
EXTEND
MP AMGB1
ADS AK
CA T5TEMP
EXTEND
MP AMGB4
# Page 1023
TS AK1
CA T5TEMP
EXTEND
MP AMGB7
TS AK2
CA WTEMP +1
EXTEND
MSU CDUZ
TS T5TEMP
EXTEND
MP AMGB5
ADS AK1
CA T5TEMP
EXTEND
MP AMGB8
ADS AK2
TCF RESUME # END PHASE1 OF RCS DAP
WRTN17 EXTEND # GET SET TO COMPUTE TOTAL ASTRONAUT
DCA CPHIX +1 # ATTITUDE ERROR WRT N17 BY PICKING UP
DXCH WTEMP # THE THREE COMPONENTS OF N17
CA CPHIX
TCF GETAKS
# Page 1024 (empty page)