* Initial try defining Variables and PhysicalProperty

Added extraction of full_shape of the PhyiscalProperty.value from variables and tensor rank

* Reorganized in 3 modules

* Added normalization for Variables.n_grid_points

* Moved sfc refs and boolean to PhysicalProperty

Added functionality to see if a property is_scf_converged

* Added testing for Variables

* Added testing for PhysicalProperty

* Fixed variables dimensions

* Added name to PhysicalProperty for custom properties

* Added testing for outputs.py

* Defined value as a placeholder_quantity default

* Improved descriptions

---------

Co-authored-by: jrudz <[email protected]>
  • Loading branch information
JosePizarro3 and jrudz authored Apr 11, 2024
1 parent cb98980 commit f03e514
Show file tree
Hide file tree
Showing 8 changed files with 806 additions and 131 deletions.
220 changes: 141 additions & 79 deletions src/nomad_simulations/outputs.py
Original file line number Diff line number Diff line change
Expand Up @@ -17,18 +17,48 @@
#

import numpy as np
from typing import Optional
from structlog.stdlib import BoundLogger
from typing import Optional

from nomad.datamodel.data import ArchiveSection
from nomad.metainfo import Quantity, SubSection, MEnum, Section, Context
from nomad.datamodel.metainfo.annotations import ELNAnnotation
from nomad.metainfo import Quantity, SubSection, SectionProxy, Reference

from .atoms_state import AtomsState, OrbitalsState
from .model_system import ModelSystem
from .physical_property import PhysicalProperty
from .numerical_settings import SelfConsistency


class ElectronicBandGap(PhysicalProperty):
""" """

rank = []

type = Quantity(
type=MEnum('direct', 'indirect'),
description="""
Type categorization of the electronic band gap. The electronic band gap can be `'direct'` or `'indirect'`.
""",
)

value = Quantity(
type=np.float64,
unit='joule',
description="""
The value of the electronic band gap.
""",
)

# TODO add more functionalities here

def __init__(self, m_def: Section = None, m_context: Context = None, **kwargs):
super().__init__(m_def, m_context, **kwargs)
self.name = self.m_def.name

def normalize(self, archive, logger) -> None:
super().normalize(archive, logger)


class Outputs(ArchiveSection):
"""
Output properties of a simulation. This base class can be used for inheritance in any of the output properties
Expand All @@ -42,33 +72,6 @@ class Outputs(ArchiveSection):

normalizer_level = 2

name = Quantity(
type=str,
description="""
Name of the output property. This is used for easier identification of the property and is connected
with the class name of each output property class, e.g., `'ElectronicBandGap'`, `'ElectronicBandStructure'`, etc.
""",
a_eln=ELNAnnotation(component='StringEditQuantity'),
)

orbitals_state_ref = Quantity(
type=OrbitalsState,
description="""
Reference to the `OrbitalsState` section to which the output property references to and on
on which the simulation is performed.
""",
a_eln=ELNAnnotation(component='ReferenceEditQuantity'),
)

atoms_state_ref = Quantity(
type=AtomsState,
description="""
Reference to the `AtomsState` section to which the output property references to and on
on which the simulation is performed.
""",
a_eln=ELNAnnotation(component='ReferenceEditQuantity'),
)

model_system_ref = Quantity(
type=ModelSystem,
description="""
Expand All @@ -78,53 +81,29 @@ class Outputs(ArchiveSection):
a_eln=ELNAnnotation(component='ReferenceEditQuantity'),
)

is_derived = Quantity(
type=bool,
default=False,
description="""
Flag indicating whether the output property is derived from other output properties. We make
the distinction between directly parsed and derived output properties:
- Directly parsed: the output property is directly parsed from the simulation output files.
- Derived: the output property is derived from other output properties. No extra numerical settings
are required to calculate the output property.
""",
)

outputs_ref = Quantity(
type=Reference(SectionProxy('Outputs')),
custom_physical_property = SubSection(
sub_section=PhysicalProperty.m_def,
repeats=True,
description="""
Reference to the `Outputs` section from which the output property was derived. This is only
relevant if `is_derived` is set to True.
A custom physical property used to store properties not yet covered by the NOMAD schema.
""",
a_eln=ELNAnnotation(component='ReferenceEditQuantity'),
)

def resolve_is_derived(self, outputs_ref) -> bool:
"""
Resolves if the output property is derived or not.
Args:
outputs_ref (_type_): The reference to the `Outputs` section from which the output property was derived.
Returns:
bool: The flag indicating whether the output property is derived or not.
"""
if outputs_ref is not None:
return True
return False
# # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # #
# List of properties
# # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # #
electronic_band_gap = SubSection(sub_section=ElectronicBandGap.m_def, repeats=True)

def normalize(self, archive, logger) -> None:
super().normalize(archive, logger)

# Resolve if the output property `is_derived` or not.
self.is_derived = self.resolve_is_derived(self.outputs_ref)
# self.is_derived = self.resolve_is_derived(self.outputs_ref)


class SCFOutputs(Outputs):
"""
This section contains the self-consistent (SCF) steps performed to converge an output property,
as well as the information if the output property `is_converged` or not, depending on the
settings in the `SelfConsistency` base class defined in `numerical_settings.py`.
This section contains the self-consistent (SCF) steps performed to converge an output property.
For simplicity, we contain the SCF steps of a simulation as part of the minimal workflow defined in NOMAD,
the `SinglePoint`, i.e., we do not split each SCF step in its own entry. Thus, each `SinglePoint`
Expand All @@ -140,23 +119,106 @@ class SCFOutputs(Outputs):
""",
)

is_scf_converged = Quantity(
type=bool,
description="""
Flag indicating whether the output property is converged or not after a SCF process. This quantity is connected
with `SelfConsistency` defined in the `numerical_settings.py` module.
""",
)
def get_last_scf_steps_value(
self,
scf_last_steps: list,
property_name: str,
i_property: int,
scf_parameters: SelfConsistency,
logger: BoundLogger,
) -> Optional[list]:
"""
Get the last two SCF values' magnitudes of a physical property and appends then in a list.
self_consistency_ref = Quantity(
type=SelfConsistency,
description="""
Reference to the `SelfConsistency` section that defines the numerical settings to converge the
output property.
""",
)
Args:
scf_last_steps (list): The list of the last two SCF steps.
property_name (str): The name of the physical property.
i_property (int): The index of the physical property.
# TODO add more functionality to automatically check convergence from `self_consistency_ref` and the last two `scf_steps`
Returns:
(Optional[list]): The list of the last two SCF values' magnitudes of a physical property.
"""
scf_values = []
for step in scf_last_steps:
scf_phys_property = getattr(step, property_name)[i_property]
try:
if scf_phys_property.value.u != scf_parameters.threshold_change_unit:
logger.error(
f'The units of the `scf_step.{property_name}.value` does not coincide with the units of the `self_consistency_ref.threshold_unit`.'
)
return []
except Exception:
return []
scf_values.append(scf_phys_property.value.magnitude)
return scf_values

def resolve_is_scf_converged(
self,
property_name: str,
i_property: int,
phys_property: PhysicalProperty,
logger: BoundLogger,
) -> Optional[bool]:
"""
Resolves if the physical property is converged or not after a SCF process. This is only ran
when there are at least two `scf_steps` elements.
Returns:
(bool): The flag indicating whether the physical property is converged or not after a SCF process.
"""
# If there are not at least 2 `scf_steps`, return None
if len(self.scf_steps) < 2:
logger.warning('The SCF normalization needs at least two SCF steps.')
return None
scf_last_steps = self.scf_steps[-2:]

# If there is not `self_consistency_ref` section, return None
scf_parameters = phys_property.self_consistency_ref
if scf_parameters is None:
return None

# Extract the value.magnitude of the phys_property to be checked if converged or not
scf_values = self.get_last_scf_steps_value(
scf_last_steps, property_name, i_property, scf_parameters, logger
)
if scf_values is None or len(scf_values) != 2:
logger.warning(
f'The SCF normalization could not resolve the SCF values for the property `{property_name}`.'
)
return None

# Compare with the `threshold_change`
scf_diff = abs(scf_values[0] - scf_values[1])
threshold_change = scf_parameters.threshold_change
if scf_diff <= threshold_change:
return True
else:
logger.info(
f'The SCF process for the property `{property_name}` did not converge.'
)
return False

def normalize(self, archive, logger) -> None:
super().normalize(archive, logger)

# Resolve the `is_scf_converged` flag for all SCF obtained properties
for property_name in self.m_def.all_sub_sections.keys():
# Skip the `scf_steps` and `custom_physical_property` sub-sections
if (
property_name == 'scf_steps'
or property_name == 'custom_physical_property'
):
continue

# Check if the physical property with that property name is populated
phys_properties = getattr(self, property_name)
if phys_properties is None:
continue
if not isinstance(phys_properties, list):
phys_properties = [phys_properties]

# Loop over the physical property of the same m_def type and set `is_scf_converged`
for i_property, phys_property in enumerate(phys_properties):
phys_property.is_scf_converged = self.resolve_is_scf_converged(
property_name, i_property, phys_property, logger
)
Loading