MRT Calculator - [source code]

Use this component calculate Mean Radiant Temperature (MRT) given a set of temperatures and corresponding view factors. This component will check to be sure view factors add to 1 and will use the following formula: MRT = (V1T1^4 + V2T2^4 + ...) ^ (1/4) Where V corresponds to a view factor and T corresponds to a temperature.

Inputs

  • temperatures [Required]

A list of radiant temperatures in Celcius that correspond to view factors below.

  • viewFactors [Required]

A list of viewFactors that correspond to the temperatures above. These should sum to 1.

Outputs

  • MRT

The Mean Radiant Temperature that results from the input temperatures and view factors.

[Check Hydra Example Files for MRT Calculator](https://hydrashare.github.io/hydra/index.html?keywords=Ladybug_MRT Calculator)