diff --git a/bin/user/netatmo.py b/bin/user/netatmo.py index 1e3e279..640475f 100644 --- a/bin/user/netatmo.py +++ b/bin/user/netatmo.py @@ -42,7 +42,7 @@ import weewx.wxformulas DRIVER_NAME = 'netatmo' -DRIVER_VERSION = "0.3" +DRIVER_VERSION = "0.4" INHG_PER_MBAR = 0.0295299830714 MPH_TO_KPH = 1.60934 @@ -69,7 +69,7 @@ def logerr(msg): def loader(config_dict, engine): return NetatmoDriver(**config_dict[DRIVER_NAME]) -def confeditor_loader(config_dict): +def confeditor_loader(): return NetatmoConfEditor() @@ -115,6 +115,8 @@ class NetatmoDriver(weewx.drivers.AbstractDevice): DEFAULT_PORT = 80 DEFAULT_HOST = '' # map from netatmo names to database schema names + # apparently battery_vp is in older firmware, whereas battery_percent is + # in newer firmware. DEFAULT_SENSOR_MAP = { '*.NAMain.AbsolutePressure': 'pressure', '*.NAMain.Temperature': 'inTemp', @@ -124,21 +126,25 @@ class NetatmoDriver(weewx.drivers.AbstractDevice): '*.NAMain.wifi_status': 'wifi_status', '*.NAModule1.Temperature': 'outTemp', '*.NAModule1.Humidity': 'outHumidity', - '*.NAModule1.rf_status': 'rf_status', - '*.NAModule1.battery_vp': 'battery_vp', + '*.NAModule1.rf_status': 'out_rf_status', + '*.NAModule1.battery_vp': 'out_battery_vp', + '*.NAModule1.battery_percent': 'outTempBatteryStatus', '*.NAModule4.Temperature': 'extraTemp1', '*.NAModule4.Humidity': 'extraHumid1', - '*.NAModule4.rf_status': 'rf_status', - '*.NAModule4.battery_vp': 'battery_vp', + '*.NAModule4.rf_status': 'extra_rf_status_1', + '*.NAModule4.battery_vp': 'extra_battery_vp_1', + '*.NAModule4.battery_percent': 'extra1BatteryStatus', '*.NAModule2.WindStrength': 'windSpeed', '*.NAModule2.WindAngle': 'windDir', '*.NAModule2.GustStrength': 'windGust', '*.NAModule2.GustAngle': 'windGustDir', - '*.NAModule2.rf_status': 'rf_status', - '*.NAModule2.battery_vp': 'battery_vp', + '*.NAModule2.rf_status': 'wind_rf_status', + '*.NAModule2.battery_vp': 'wind_battery_vp', + '*.NAModule2.battery_percent': 'windBatteryStatus', '*.NAModule3.Rain': 'rain', - '*.NAModule3.rf_status': 'rf_status', - '*.NAModule3.battery_vp': 'battery_vp'} + '*.NAModule3.rf_status': 'rain_rf_status', + '*.NAModule3.battery_vp': 'rain_battery_vp', + '*.NAModule3.battery_percent': 'rainBatteryStatus'} def __init__(self, **stn_dict): loginf("driver version is %s" % DRIVER_VERSION) @@ -154,7 +160,7 @@ def __init__(self, **stn_dict): elif mode.lower() == 'cloud': max_tries = int(stn_dict.get('max_tries', 5)) retry_wait = int(stn_dict.get('retry_wait', 10)) # seconds - poll_interval = int(stn_dict.get('poll_interval', 600)) # seconds + poll_interval = int(stn_dict.get('poll_interval', 300)) # seconds username = stn_dict['username'] password = stn_dict['password'] client_id = stn_dict['client_id'] @@ -166,7 +172,7 @@ def __init__(self, **stn_dict): else: raise ValueError("unsupported mode '%s'" % mode) self.collector.startup() - + def closePort(self): self.collector.shutdown() @@ -246,7 +252,7 @@ class CloudClient(Collector): lang: user locale reg_locale: regional preferences for date feel_like_algo: 0: humidex, 1: heat-index - + rf_status is a mapping to rssi (+dB) 0: 90, 1: 80, 2: 70, 3: 60 wifi_status is a mapping to rssi (+dB) @@ -282,10 +288,11 @@ class CloudClient(Collector): META_ITEMS = [ 'wifi_status', 'rf_status', 'battery_vp', 'co2_calibrating', '_id', 'module_name', 'last_status_store', 'last_seen', + 'battery_percent', 'firmware', 'last_setup', 'last_upgrade', 'date_setup'] def __init__(self, username, password, client_id, client_secret, - device_id=None, poll_interval=600, max_tries=3, retry_wait=30): + device_id=None, poll_interval=300, max_tries=3, retry_wait=30): self._poll_interval = poll_interval self._max_tries = max_tries self._retry_wait = retry_wait @@ -310,7 +317,8 @@ def collect_data(self): logerr("failed attempt %s of %s to get data: %s" % (tries + 1, self._max_tries, e)) logdbg("waiting %s seconds before retry" % - self.retry_wait) + self._retry_wait) + time.sleep(self._retry_wait) else: logerr("failed to get data after %d attempts" % self._max_tries) @@ -383,7 +391,7 @@ def _cvt_pressure(x, from_unit_dict): @staticmethod def _cvt_speed(x, from_unit_dict): - # windunit: 0: kph, 1: mph, 2: m/s, 3: beafort, 4: knot + # windunit: 0: kph, 1: mph, 2: m/s, 3: beafort, 4: knot if from_unit_dict['windunit'] == 1: x *= MPH_TO_KPH elif from_unit_dict['windunit'] == 2: @@ -484,7 +492,7 @@ def __init__(self, auth): self._last_update = 0 self._raw_data = dict() - def get_data(self, device_id=None, stale=600): + def get_data(self, device_id=None, stale=300): if int(time.time()) - self._last_update > stale: params = {'access_token': self._auth.access_token} if device_id: @@ -507,7 +515,7 @@ def post_request(url, params): resp_obj = json.loads(resp) logdbg("resp_obj: %s" % resp_obj) return resp_obj - + class PacketSniffer(Collector): """listen for incoming packets then parse them. put result on queue.""" @@ -625,7 +633,7 @@ def get_station_data(username, password, c_id, c_secret): def get_json_data(username, password, c_id, c_secret): auth = CloudClient.ClientAuth(username, password, c_id, c_secret) params = {'access_token': auth.access_token, 'app_type': 'app_station'} - reply = CloudClient.post_request(CloudClient.DEVICELIST_URL, params) + reply = CloudClient.post_request(CloudClient.DATA_URL, params) print json.dumps(reply, sort_keys=True, indent=2) def test_parse(filename): diff --git a/changelog b/changelog index 93ee78a..79039ad 100644 --- a/changelog +++ b/changelog @@ -1,3 +1,10 @@ +0.4 06aug2016 +* incorporate changes from scott grey +* default poll interval is now 300 instead of 600 +* wait before retry when network failures +* fixed DEVICELIST_URL bug +* fixed confgeditor invocation + 0.3 04aug2016 * fix for rain calculation diff --git a/install.py b/install.py index 8b51f19..b4ef1c5 100644 --- a/install.py +++ b/install.py @@ -10,7 +10,7 @@ def loader(): class NetatmoInstaller(ExtensionInstaller): def __init__(self): super(NetatmoInstaller, self).__init__( - version="0.3", + version="0.4", name='netatmo', description='Driver for netatmo weather stations.', author="Matthew Wall", diff --git a/readme.txt b/readme.txt index e6af159..eba92b7 100644 --- a/readme.txt +++ b/readme.txt @@ -28,11 +28,11 @@ wget -O weewx-netatmo.zip https://github.com/matthewwall/weewx-netatmo/archive/m 1) install the driver: -wee_extension --install weewx-netatmo.zip +sudo wee_extension --install weewx-netatmo.zip 2) select and configure the driver: -wee_config --reconfigure +sudo wee_config --reconfigure 3) start weewx: