end stop temperature error #108

Open
scymz opened this issue Dec 28, 2023 · 2 comments
Open

end stop temperature error #108

scymz opened this issue Dec 28, 2023 · 2 comments

Comments

@scymz
Copy link

scymz commented Dec 28, 2023

When my x and y optical endstops are closed, the temperatures appear as err. It has been said in some places that it is related to 5v. Has anyone encountered this situation and been able to solve it?

@PanosPetrou
Copy link

Most likely your endstops are wired with a wrong pin order and when they engage, they short circuit the 5V rail. Check your wiring and pinout.

@scymz
Copy link
Author

scymz commented Apr 30, 2024

Most likely your endstops are wired with a wrong pin order and when they engage, they short circuit the 5V rail. Check your wiring and pinout.

My cable connections are correct, I make connections according to the order on the board. When I disconnect the 5v connection on the mechanical endstop, it works properly, but it does not work on the optical endstop, it always appears in the triggered position.