edid-decode (hex):
00 ff ff ff ff ff ff 00 06 af ec 47 00 00 00 00
00 17 01 04 95 22 13 78 02 0b b5 97 57 54 8c 26
23 50 54 00 00 00 01 01 01 01 01 01 01 01 01 01
01 01 01 01 01 01 ce 1d 56 e2 50 00 1e 30 26 16
36 00 58 c1 10 00 00 18 00 00 00 0f 00 00 00 00
00 00 00 00 00 00 00 00 00 20 00 00 00 fe 00 41
55 4f 0a 20 20 20 20 20 20 20 20 20 00 00 00 fe
00 42 31 35 36 58 57 30 30 34 2e 37 20 0a 00 d5
----------------
Block 0, Base EDID:
EDID Structure Version & Revision: 1.4
Vendor & Product Identification:
Manufacturer: AUO
Model: 18412
Made in: 2013
Basic Display Parameters & Features:
Digital display
Bits per primary color channel: 6
DisplayPort interface
Maximum image size: 34 cm x 19 cm
Gamma: 2.20
Supported color formats: RGB 4:4:4
First detailed timing includes the native pixel format and preferred refresh rate
Color Characteristics:
Red : 0.5898, 0.3398
Green: 0.3300, 0.5498
Blue : 0.1503, 0.1396
White: 0.3134, 0.3291
Established Timings I & II: none
Standard Timings: none
Detailed Timing Descriptors:
DTD 1: 1366x768 60.059067 Hz 683:384 47.927 kHz 76.300000 MHz (344 mm x 193 mm)
Hfront 38 Hsync 22 Hback 166 Hpol N
Vfront 3 Vsync 6 Vback 21 Vpol N
Manufacturer-Specified Display Descriptor (0x0f): 00 0f 00 00 00 00 00 00 00 00 00 00 00 00 00 20 '............... '
Alphanumeric Data String: 'AUO'
Alphanumeric Data String: 'B156XW004.7 '
Checksum: 0xd5
----------------
Warnings:
Block 0, Base EDID:
Missing Display Product Name.
Failures:
Block 0, Base EDID:
Alphanumeric Data String: One or more trailing spaces.
EDID conformity: FAIL