edid-decode (hex):
00 ff ff ff ff ff ff 00 06 af 44 21 00 00 00 00
01 0f 01 03 80 1e 13 78 0a 87 c5 94 57 4f 8c 27
25 50 54 00 00 00 01 01 01 01 01 01 01 01 01 01
01 01 01 01 01 01 c7 1b 00 a0 50 20 17 30 30 20
36 00 30 be 10 00 00 18 00 00 00 0f 00 00 00 00
00 00 00 00 00 00 00 00 00 20 00 00 00 fe 00 41
55 4f 0a 20 20 20 20 20 20 20 20 20 00 00 00 fe
00 42 31 34 31 45 57 30 32 20 56 31 20 0a 00 dd
----------------
Block 0, Base EDID:
EDID Structure Version & Revision: 1.3
Vendor & Product Identification:
Manufacturer: AUO
Model: 8516
Made in: week 1 of 2005
Basic Display Parameters & Features:
Digital display
Maximum image size: 30 cm x 19 cm
Gamma: 2.20
RGB color display
First detailed timing is the preferred timing
Color Characteristics:
Red : 0.5800, 0.3398
Green: 0.3095, 0.5498
Blue : 0.1552, 0.1445
White: 0.3134, 0.3291
Established Timings I & II: none
Standard Timings: none
Detailed Timing Descriptors:
DTD 1: 1280x800 60.002363 Hz 16:10 49.382 kHz 71.110000 MHz (304 mm x 190 mm)
Hfront 48 Hsync 32 Hback 80 Hpol N
Vfront 3 Vsync 6 Vback 14 Vpol N
Manufacturer-Specified Display Descriptor (0x0f): 00 0f 00 00 00 00 00 00 00 00 00 00 00 00 00 20 '............... '
Alphanumeric Data String: 'AUO'
Alphanumeric Data String: 'B141EW02 V1 '
Checksum: 0xdd
----------------
Failures:
Block 0, Base EDID:
Alphanumeric Data String: One or more trailing spaces.
Missing Display Product Name.
Missing Display Range Limits Descriptor.
EDID conformity: FAIL