Article: Q159777
Product(s): Microsoft SourceSafe
Version(s): 5.0,6.0
Operating System(s):
Keyword(s): kberrmsg kbSSafe500bug kbSSafe600fix kbgrpdsvc
Last Modified: 06-MAY-2002
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Visual SourceSafe for Windows, versions 5.0, 6.0
-------------------------------------------------------------------------------
SYMPTOMS
========
When you log on to Visual SourceSafe, the following error message might appear:
Invalid Syntax on line <line #> of the file <path to user's SS.INI
file>\SS.INI
When you use the command line, the following error message might appear:
Invalid Syntax on line <line #> of the file <path to user's SS.INI
file>\SS.INI Too many SS.INI environment settings
In both error messages, <line #> is some integer and <path to user's
SS.ini file> is the MS-DOS path to the user's SS.ini file.
CAUSE
=====
This error occurs in Visual SourceSafe 5.0 if your SS.ini file references
settings for more than 10 computers.
In Visual SourceSafe version 6.0 the situation has improved. The error now occurs
only if your SS.ini file references settings for more than 24 computers.
RESOLUTION
==========
Manually edit the user's SS.ini file, and reduce the number of references to
computer names to 10 or less for version 5.0 or 24 or less for version 6.0.
STATUS
======
Microsoft has confirmed this to be a bug in the Microsoft products listed at the
beginning of this article.
MORE INFORMATION
================
In Visual SourceSafe, user settings such as window size and window state, are
all saved to the user's SS.ini file. This is done to preserve the appearance of
the Visual SourceSafe Explorer from one Visual SourceSafe session to another.
Each entry is identified with a machine name. If users log on from MachineA,
their SS.ini might contain entries like the following:
Maximized (MachineA) = No
PrjWidth (MachineA) = 260
If they log on from MachineB later on, then a section of the SS.INI might look
like the following:
Maximized (MachineA) = No
PrjWidth (MachineA) = 260
Maximized (MachineB) = Yes
PrjWidth (MachineB) = 300
Users can log on to Visual SourceSafe from 10 different machines successfully.
However, once they attempt to log on from the 11th machine, the above error
messages appears.
Steps to Reproduce Problem
--------------------------
1. Open your SS.ini file into a text editor, such as Microsoft Notepad. Your
SS.ini file is located in \\Vss\Users\<your SourceSafe user name>.
2. Modify this file so that it contains references to 11 or more different
computer names in Visual SourceSafe version 5.0 or 25 or more for Visual
SourceSafe version 6.0. You can do this by copying one line and pasting it
back into the file ten times and then modifying each line to make it unique,
for example:
(Beginning of the file goes here)
Hist_Rect (RIGEL1) = 188, 225, 721, 561, 1024, 768
History_File_Columns (UI) = 75,85,135,100
Maximized (RIGEL1) = No
mssccprj = *.vbp, *.mak
OutputHeight (TIMWIN1) = 150
Position_Toolbar (TIMWIN1) = 222, 183, 676, 215, 1280, 1024
PrjWidth (RIGEL1) = 260
PrjWidth (RIGEL2) = 260
PrjWidth (RIGEL3) = 260
PrjWidth (RIGEL4) = 260
PrjWidth (RIGEL5) = 260
PrjWidth (RIGEL6) = 260
PrjWidth (RIGEL7) = 260
PrjWidth (RIGEL8) = 260
PrjWidth (RIGEL9) = 260
PrjWidth (RIGEL10) = 260
PrjWidth (RIGEL11) = 260
Toolbar (RIGEL2) = Yes
(etc. etc.)
3. Start the Visual SourceSafe Explorer or use the command line. Note that the
above error messages appear.
Additional query words:
======================================================================
Keywords : kberrmsg kbSSafe500bug kbSSafe600fix kbgrpdsvc
Technology : kbSSafeSearch kbAudDeveloper kbSSafe500
Version : :5.0,6.0
Issue type : kbbug
Solution Type : kbfix
=============================================================================
{% endraw %}