On my DSO203 I recognized that after recalibration after power cycling all calibration data have been lost. I now need to "Reset calib data" every time I want to work with the scope.
When I connect via USB to my Laptop it says that the file system is corrupt.
I also cannot get the firmware partition connected to the laptop. So I assume there is a problem with the file system.
Any thoughts how to fix this?
The text was updated successfully, but these errors were encountered:
After reflashing the FPGA configuration, reinstalling the original software and then installed a version of the software saving of calibration data worked. My assumption is that the Flash-Partition got corrupt and reflashing the firmware reinitialized it.
HW 2.7B, DFU 3.1
Installing:
FPGA 2.61 *
SYS B1.52
APP B2.50
GAB_O2.HEX
LOGO_000.BIN *
(* first copied .ADR File into DFU-partition then FPGA resp. LOGO file)
(This was a lengthy operation since I had to revitalize a Windows 7 computer since the DFU 3.1 does not work with Windows 10)
On my DSO203 I recognized that after recalibration after power cycling all calibration data have been lost. I now need to "Reset calib data" every time I want to work with the scope.
When I connect via USB to my Laptop it says that the file system is corrupt.
I also cannot get the firmware partition connected to the laptop. So I assume there is a problem with the file system.
Any thoughts how to fix this?
The text was updated successfully, but these errors were encountered: