You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Good day!
I have got a shelly gas sensor with the shelly valve. The valve and its status (Open/Close) is not detected from your plugin.
Can you support this implementation ?
have a nice day
The text was updated successfully, but these errors were encountered:
Yes, it can be done. According the shelly docs this is the valve mqtt path: shellies/shellygas-<deviceid>/valve/0/state
and this is the possible values, so it can be a selector type, not a binary:
unknown = Valve state is unknown
closed = Valve is closed
opened = Valve is opened
not_connected = Valve is not connected
failure = Valve failure detected
closing = Valve is in the process of closing
opening = Valve is in the process of opening
checking = Valve state is being checked
I can confirm all.
"closed" , "opened", and "not connected" are the more important states.
"closing" and "opening" are active during the changing position.
if you need some logs from my mosquitto mqtt server or something else, let me know.
I'd like to use this integration for create an event, in domoticz, that close the gas valve when you left home, and reopen when you came back.
;-)
Good day!
I have got a shelly gas sensor with the shelly valve. The valve and its status (Open/Close) is not detected from your plugin.
Can you support this implementation ?
have a nice day
The text was updated successfully, but these errors were encountered: