Notifications
You must be signed in to change notification settings - Fork 0
/
CapitalCost_Water.m
117 lines (98 loc) · 4.75 KB
/
CapitalCost_Water.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
function result = CapitalCost_Water(Q_preheater_total, Q_boiler_total, W_turbine_total, Q_recuperator_total, Q_desuperheater_total, ...
Q_condenser_total, W_pump_orc_total, W_pump_prod_total, ...
dT_range_CT, dT_LMTD_preheater, dT_LMTD_boiler, dT_LMTD_recuperator, params)
% All heat/power in Watts
%Check that simulation is for water
if (strcmp(params.fluid,'Water') == false)
throw(MException('CapitalCost_Water:Wrong_Fluid','Wrong Fluid--Not Water'));
end
% Capital Cost is
% 1. Surface Plant
% 2. Gathering System
% 3. Wells
% 4. Wellfield Development
% 5. Exploration
% 6. Well Stimulation
% 1. Surface Plant
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
result_surfacePlant = CapitalCost_SurfacePlant_ORC(Q_preheater_total, Q_boiler_total, W_turbine_total, Q_recuperator_total, Q_desuperheater_total, Q_condenser_total, ...
W_pump_orc_total, W_pump_prod_total, dT_range_CT, dT_LMTD_preheater, dT_LMTD_boiler, dT_LMTD_recuperator, params);
% 2. Gathering System
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
if (params.hasSurfaceGatheringSystem == true)
C_gatheringSystem = CapitalCost_SurfacePipe(params);
else
C_gatheringSystem = 0;
end
% 3. Well Cost
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Number of wells to pay for
if (strcmp(params.wellFieldType,'Doublet'))
G_wells_injection = 1;
G_wells_production = 1;
elseif (strcmp(params.wellFieldType,'5spot'))
G_wells_injection = 1;
G_wells_production = 4;
elseif (strcmp(params.wellFieldType,'5spot_SharedNeighbor'))
G_wells_injection = 1;
G_wells_production = 1;
elseif (strcmp(params.wellFieldType,'5spot_ManyN'))
G_wells_injection = N_5spot^2;
G_wells_production = (N_5spot+1)^2;
elseif (strcmp(params.wellFieldType,'Tungsten'))
G_wells_injection = 4;
G_wells_production = 4;
else
throw(MException('CapitalCost_Water:BadWellFieldType','Bad WellFieldType'));
end
%If conduction system, the wellLength is the depth plus half reservoir
%length
C_well_vertical = CapitalCost_Well(params.depth, 2*params.well_radius, params.fluid, params.SuccessRate_well, params);
C_well_horizontal = CapitalCost_Well((params.depth+0.5*params.res_length), 2*params.well_radius, params.fluid, params.SuccessRate_well, params) - C_well_vertical;
if (strcmp(params.system,'Porous'))
C_well = C_well_vertical;
else
C_well = C_well_vertical + params.n_streams*C_well_horizontal
% elseif (strcmp(params.system,'Conduction1'))
% C_well = C_well_vertical + C_well_horizontal;
% elseif (strcmp(params.system,'Conduction2'))
% C_well = C_well_vertical + 2*C_well_horizontal;
% elseif (strcmp(params.system,'Conduction4'))
% C_well = C_well_vertical + 4*C_well_horizontal;
% elseif (strcmp(params.system,'Conduction8'))
% C_well = C_well_vertical + 8*C_well_horizontal;
% else
% throw(MException('CapitalCost_Water:NotImplemented','CapitalCost_Water:Not Implemented'));
end
C_wells_injection = G_wells_injection * C_well;
C_wells_production = G_wells_production * C_well;
% 4. Wellfield Development
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
C_wellfield = CapitalCost_Wellfield(params);
% 5. Exploration
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% No exploration costs if conduction system
if (strcmp(params.system,'Porous'))
C_exploration = CapitalCost_Exploration(params);
elseif (contains(params.system,'Conduction'))
C_exploration = 0;
else
throw(MException('CapitalCost_Water:NotImplemented','Not Implemented'));
end
% 6. Well Stimulation
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
C_stimulation = 0;
% SUM IT UP
C_brownfield = result_surfacePlant.C_plant + C_gatheringSystem + C_wells_production;
C_greenfield = result_surfacePlant.C_plant + C_gatheringSystem + C_wells_production + C_wells_injection + C_wellfield + C_exploration + C_stimulation;
result.CostSurfacePlant = result_surfacePlant;
result.C_surfacePlant = result_surfacePlant.C_plant;
result.C_gatheringSystem = C_gatheringSystem;
result.C_wells_production = C_wells_production;
result.C_wells_injection = C_wells_injection;
result.C_wellfield = C_wellfield;
result.C_exploration = C_exploration;
result.C_stimulation = C_stimulation;
result.C_brownfield = C_brownfield;
result.C_greenfield = C_greenfield;
end