Signal speed used in tcour should include radiation pressure #474

Merged
merged 5 commits into from
Oct 23, 2023

Conversation

themikelau
Copy link
Collaborator

Add contribution of radiation pressure to signal speed when using radiation (e.g., Eq 10 in https://arxiv.org/abs/1102.1216). We should have cs = (5/3Pgas/rho + 4/3Prad/rho)^1/2. Otherwise, tcour may be underestimated.

@danieljprice
Copy link
Owner

this is a good idea, however we should test before merging as it would also increase the shock viscosity. Best problem for this would be the radiation shock tube (radshock) although we'd need to do it in a regime where radiation pressure is significant to see what difference this makes to the shock capturing (and indeed the stability)

@danieljprice danieljprice merged commit 420f5a6 into master Oct 23, 2023
177 checks passed
@danieljprice danieljprice deleted the tcourant branch October 23, 2023 21:19