You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This library seems to have hardcoded values for all the FIFO frame lengths, so if I set the auxiliary sensor read length to anything other than 8 bytes the data is incorrectly interpreted.
The work-around is just to set the read length to 8 bytes.
The text was updated successfully, but these errors were encountered:
This library seems to have hardcoded values for all the FIFO frame lengths, so if I set the auxiliary sensor read length to anything other than 8 bytes the data is incorrectly interpreted.
The work-around is just to set the read length to 8 bytes.
The text was updated successfully, but these errors were encountered: