Skip to content

Latest commit

 

History

History
64 lines (45 loc) · 2.98 KB

DataStax_Studio_6.8_Release_Notes.md

File metadata and controls

64 lines (45 loc) · 2.98 KB

Release notes for DataStax Studio 6.8

Release notes for DataStax Studio 6.8.11

03 May 2021

Studio 6.8.11 Client

  • Updates the Create/Edit Astra Connection dialog to use field names "Client ID" and "Client Secret". (STUDIO-3184)
  • Add IDE support to recognize the "split_during_flush" option of the TimeWindowCompactionStrategy (TWCS). (STUDIO-3190)

Studio 6.8.11 Server

  • CVE updates to jackson-databind, guava, jetty, commons-compress and async-http-client libraries (STUDIO-3182)
  • Add "Getting Started with Astra" tutorial notebook. (STUDIO-3183)
  • Fix issue displaying the wrong DC value in the Notebook connection information bar; the DC value shown should always be the local datacenter based on the given contact points in the Connection configuration. (STUDIO-3187)
  • Fix "Error Writing" exception when executing certain CQL GRANT statements. (STUDIO-3189)
  • Fix NullPointerException when mixed case keyspace or table name is used with DESCRIBE ACTIVE|PENDING SEARCH INDEX SCHEMA ON <keyspace>.<table> statement. (STUDIO-3186)

(:information_source: Note: there was no Studio 6.8.10 release)

Release notes for DataStax Studio 6.8.9

29 January 2021

Studio 6.8.9 Client

  • Increases the display width of graph names in drop down menus, and adds a tooltip with the full graph name to the Notebook graph drop down menu. (STUDIO-3178)

Studio 6.8.9 Server

  • Fixes a startup bash script issue when the Java path contains spaces, which may happen after macOS upgrade to Big Sur. (STUDIO-3179)

(note: there was no Studio 6.8.7 or 6.8.8 release)

Release notes for DataStax Studio 6.8.6

19 November 2020

Studio 6.8.6 Client

  • Cluster information is displayed in the top bar of a Notebook. (STUDIO-3138)
  • Fixes broken documentation links in the Create Graph dialog. (STUDIO-3138)

Studio 6.8.6 IDE

  • Fixes a problem that can spam the log with 'No enum constant found for name' messages. (STUDIO-3174)
  • Fixes a problem with detection of classic or core graph in Gremlin cells. (STUDIO-3138)

Studio 6.8.6 Server

  • Reduces advanced workload connection attempts when those workloads are not present in the cluster. (STUDIO-3138)
  • Fixes possible errors if multiple CQL or Spark SQL cells are executed at the same time. (STUDIO-3175)

(note: there was no Studio 6.8.5 release)

Release notes for DataStax Studio 6.8.4

24 September 2020

Studio 6.8.4 Client

  • Storage-attached indexes (SAI) are displayed in the schema viewer. (STUDIO-3162)

Studio 6.8.4 Schema

  • Storage-attached indexes (SAI) are displayed in the schema viewer. (STUDIO-3162)

Studio 6.8.4 Server

  • Storage-attached indexes (SAI) are displayed in the schema viewer. (STUDIO-3162)
  • Notebook import accepts .zip files. (STUDIO-3157)
  • Fixes a problem starting Studio on Windows if the java path contains a space. (STUDIO-3161)

Older Release Notes

Release notes for prior versions of DataStax Studio are available on the DataStax website.