Notifications
You must be signed in to change notification settings - Fork 4
/
sensor_server.py
280 lines (234 loc) · 11 KB
/
sensor_server.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
#! /usr/bin/python3
# -*- coding: utf-8 -*-
"""Server that reads values from different sensors for lab test.
This script is a server that is supposed to run on a RPi with the
adequate sensors hooked to it via GPIO.
It reads the value of the sensors then store them on disk or on
the usb drive if one is plugged, it also always export local data on
the usb drive if there are local data.
The measurements are always stored in csv format in "/srv/sensors/" or directly at the root of the usb.
The sensors are:
BME280 GY-BME280 : ambient temperature humidity and barometric pressure
DS18B20 : water temperature: Direct waterproof DS18B20 digital temperature sensor (probe)
Turbidity Sensor (dishwasher) : turbidity of water
DFRobot Gravity Analog/Digital Turbidity Sensor, 5V 40mA DC
3 pressure sensors : 0-5psi 5V Pressure Transducer Transmitter Sensor or Sender
flow sensor : flowrate and total liters. It is possible to choose between two different types of flowmeters:
1- Eletro-magnetic flowmeter (Danfoss Mag) - connected via serial port
2- 1.25" DN32 1~120L/min water Plastic Hall Turbine flow sensor industry meter (Sea brand)
It also records the time and date of the measure.
"""
# Libraries required
from time import sleep
from analogsensor_thread_buf import AnalogSensor, GAIN, DATA_RATE
from digitalSen_thread import D_Temp
import FlowMAG # for the eletromagnetic flow meter from Danfoss
import multiprocessing # the reading of FLOWMAG is placed in a different process
from datetime import datetime
import turbidity_calibration # to get data from a txt with calibrated turbidity sensor
import pigpio # needs to be installed for callback https://www.raspberrypi.org/forums/viewtopic.php?t=66445
import Adafruit_ADS1x15 # Analogic digital conversor ADS 15 bit 2^15-1=32767 (needs to be installed using pip3)
adc = Adafruit_ADS1x15.ADS1115(address=0x48, busnum=1) # address of ADC See in -- sudo i2cdetect -y 1
# Constants
PATH_TO_MEDIA = '/media' # to save in USB flash drive placed in raspberry pi
#Channel numbers in ads1115 analog to digital converter DAC
PRESSUP_ch = 0 # piezometric pressure in upstream chamber
PRESSINT_ch = 1 # piezometric pressure in interface
PRESSDW_ch = 2 # piezometric pressure in downstream chamber
TURB_ch = 3 # turbidity of outlet water
# Relation Gain voltages for ADS1115 chip:
# - 2/3 = +/-6.144V
# - 1 = +/-4.096V
# - 2 = +/-2.048V
# - 4 = +/-1.024V
# - 8 = +/-0.512V
# - 16 = +/-0.256V
if GAIN == 1:
max_VOLT = 4.096
elif GAIN == 2:
max_VOLT = 2.048
elif GAIN == 4:
max_VOLT = 1.024
elif GAIN == 4:
max_VOLT = 0.512
elif GAIN == 4:
max_VOLT = 0.256
else: # GAIN == 2/3
max_VOLT = 6.144
#For the flowmeter
FLOW_ch = 25 #GPIO25 in raspberry pi3
pi = pigpio.pi() # connect to Pi
if not pi.connected:
exit()
pi.set_mode(FLOW_ch, pigpio.INPUT)
pi.set_pull_up_down(FLOW_ch, pigpio.PUD_UP)
callback = pi.callback(FLOW_ch) # default tally callback
# Global variables
analog_sensor = None # for thread of analog sensors
analogTread_flag = False
d_temp_sensor = None # for thread of temperature sensors (digital)
tempTread_flag = False
global zerou, zeroi, zerod # to zeroing the piezometric pressures (datum)
def init(interval, no_reads, flowmeter):
global analog_sensor
global d_temp_sensor
global pulses, flowrate
global v1,v2,p
pulses = 0 #starts the counting of pulses of the turbine flowmeter
flowrate = 0 #starts the counting of the flowrate of the eletromagnetic flowmeter
sleep = interval / no_reads
#create the threads ('parallel' calculations for analog sensors and temp sensors)
global tempTread_flag
if tempTread_flag == False: # avoids having multiple threats d_temp_sensor running
d_temp_sensor = D_Temp(interval - 0.1) # the sensor takes +-0.750s to read. so it's placed in a thread)
d_temp_sensor.name = "dig temp sensors" #give a name to thread for better debugging
d_temp_sensor.start()
tempTread_flag = True
global analogTread_flag
if analogTread_flag == False: # avoids having multiple threats analog_sensor running
analog_sensor = AnalogSensor(sleep,no_reads) # average readings in the analog sensors per measure interval for signal stability)
analog_sensor.name = "analog_sensors"
analog_sensor.start()
analogTread_flag = True
if flowmeter == "1": # 1= eletroMagnetic flowmeter; 2 = turbine flowmeter
# create a process only to read the eletromagnetic flowmeter
# first see if any process to read the eletromag flowmeter is running and, if so, terminates it.
try:
p.terminate()
except: pass
v1 = multiprocessing.Value('d', 0.0) # flow rate -> value for shared memory between parent(main)
v2 = multiprocessing.Value('d', 0.0) # total volume -> value for shared memory
p = multiprocessing.Process(target=FlowMAG.read_flowMAG, args=(v1,v2,)) # parallel process
p.start()
def zero_press(mu, mi, md, bu, bi, bd, testtype):
# Transform the analog numbers in volts # 15 bit value
volts = [0]*3
zerou = zeroi = zerod = 0 # values to zero pressure sensors - datum
analog = [0]*3
for ch in range(3):
analog[ch] = adc.read_adc(ch, gain=GAIN, data_rate=DATA_RATE)
# transform the analog number in volts
# Ratio of 15 bit value to max volts determines volts
volts[ch] = analog[ch] / 32767.0 * max_VOLT
#determine the value to add in order to zero pressures
zerou = (mu * volts[PRESSUP_ch] + bu)
if testtype == '3': # if the test is a HET (there is no intermediate pressure sensor)
zeroi = 0
else:
zeroi = (mi * volts[PRESSINT_ch]+ bi)
zerod = (md * volts[PRESSDW_ch] + bd)
sleep(1) # waits a second
return zerou, zeroi, zerod
def get_data(interval, mu, mi, md, bu, bi, bd, zerou, zeroi, zerod, testtype, flowmeter, cf): #
"""Get the data from the sensors, also get the date and time.
Data recorded:
time (str): the time of the record in HH:MM:SS format.
date (str): the date of the record in DD-MM-YYYY format.
mmH2O_up (float): pressure in the upstream piezometer in mmH2O
mmH2O_int (float): pressure in the piezometer at the interface (middle) in mmH2O
mmH2O_dwn (float): pressure in the downstream piezometer in mmH2O
flowrate (float): instantaneous flowrate in L/hour
total_liters (float): Volume of fluid since start of program in Liters
turb (int): the analog value of the turbidity (from 0 to 32768).
water_temp (float): the temperature of the water in Celsius.
air_temp (float): the ambient temperature in Celsius.
air_hum (float): the ambient humidity in %
air_pres (float): the barometric pressure in hectoPascal (around 1000 hPa).
Returns:
dict: The data in the order of the fieldnames.
"""
global analog_sensor
global d_temp_sensor
global pulses, flowrate
global v1,v2,p
# Date (DD-MM-YYY) and time (HH:MM:SS)
d = datetime.now()
time_ = '{:%H:%M:%S}'.format(d)
date_ = '{:%Y-%m-%d}'.format(d)
# (DS18B) Water temperature + BME280
water_temp, air_temp, air_hum, air_pres = d_temp_sensor.read_d_temp()
#FLOWMETERS
if flowmeter == "1": # if eletromagnetic flowmeter is selected
#flowmeter: MAGFLOW (eletromagnetic flowmeter).
# Gets values from the parallel process which are in shared memory
flowrate = v1.value # in liters per hour
total_liters = v2.value # in liters
else: # Attention: if any other value rather than "1" is introduced in .ini file, then the program considers the turbine flowmeter!
#flowmeter: turbine
if cf == "": cf="0.45" # in case the cf variable is not set in ini file
pulses_last = pulses
pulses = callback.tally()
total_liters = (pulses) / (float(cf)*60) # 1L water = 0.45 x 60 = 27 pulses (device specs)
flowrate = ((pulses - pulses_last) / interval / float(cf))*60 # f (Hz) = cf x Q , with Q = L/min (cf = 0.45 device specs)
# Transform the analog numbers in volts
volts = [0] * 3
bar = [0] * 3
mmH2O = [0] * 3
bar_to_mmH2O = 10197.162129779283
analog = analog_sensor.read_analog() # get the actual reading from average
for ch in range(0,3,1):
if analog[ch] != 32767: # The pcb has a pull-up resister that is used to check if there is no sensor attached.
# Ratio of 15 bit value to max volts determines volts
volts[ch] = analog[ch] / 32767 * max_VOLT
else:
volts[ch] = 0 # only pull-up resistor is present
# linear relationship between psi & voltage in the pressure sensors(from manufacturer)
if volts[PRESSUP_ch] != 0:
bar[PRESSUP_ch] = (mu * volts[PRESSUP_ch] + bu) - zerou # 0 psi(bar) = 0.5v ; 15psi(*psi_to_bar) = 4.5V
else:
bar[PRESSUP_ch] = 0
if volts[PRESSINT_ch] != 0:
bar[PRESSINT_ch] = (mi * volts[PRESSINT_ch] + bi) - zeroi # 0 psi(bar) = 0.5v ; 5psi(*psi_to_bar) = 4.5V
else:
bar[PRESSINT_ch] = 0
if volts[PRESSDW_ch] != 0:
bar[PRESSDW_ch] = (md * volts[PRESSDW_ch] + bd) - zerod # 0 psi(bar) = 0.5v ; 5psi(*psi_to_bar) = 4.5V
else:
bar[PRESSDW_ch] = 0
for ch in range(3):
if volts[ch] != 0:
mmH2O[ch] = bar[ch] * bar_to_mmH2O # mmH2O conversion
else:
mmH2O[ch]=0
if testtype == '3': #HET
volts[PRESSINT_ch]= 0
bar[PRESSINT_ch]= 0
mmH2O[PRESSINT_ch]= 0
turb_analog = analog[TURB_ch] # analog 0 to 32767
if turb_analog != 32767: # value given by pull-up resistor -> nothing connected
turb = turbidity_calibration.turb_interpolate(turb_analog)
turb=float(turb)
else:
turb = 0
return {
'date': date_,
'time': time_,
'v_up': volts[PRESSUP_ch], #V
'v_int': volts[PRESSINT_ch], #V
'v_down': volts[PRESSDW_ch], #V
'bar_up': bar[PRESSUP_ch], #bar
'bar_int': bar[PRESSINT_ch], #bar
'bar_down': bar[PRESSDW_ch], #bar
'mmH2O_up': round(mmH2O[PRESSUP_ch]),
'mmH2O_int': round(mmH2O[PRESSINT_ch]),
'mmH2O_down': round(mmH2O[PRESSDW_ch]),
'ana_turb': round(analog[TURB_ch]), #analog number
'turb': round(turb,3),
'flow': round(flowrate,2),
'liters': round(total_liters,2),
'water_temp': round(water_temp,1),
'air_temp': round(air_temp,1),
'air_hum': round(air_hum,1),
'air_pres': round(air_pres),
}
#for testing
#init(5,1)
#get_data(5,.4,.4,.4,.4,.4,.4,.4,.4,0.01,0.01,0.01,1) #( dummy values )
#
# callback.cancel() # cancel callback
# pi.stop() # disconnect from Pi
#
# print("\nexiting")
# end(RUN_TIME)
# os._exit(0)