forked from open62541/open62541
-
Notifications
You must be signed in to change notification settings - Fork 0
/
tutorial_server_object.c
332 lines (300 loc) · 14.2 KB
/
tutorial_server_object.c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
/* This work is licensed under a Creative Commons CCZero 1.0 Universal License.
* See http://creativecommons.org/publicdomain/zero/1.0/ for more information. */
#include <open62541/plugin/log_stdout.h>
#include <open62541/server.h>
/**
* Working with Objects and Object Types
* -------------------------------------
*
* Using objects to structure information models
* ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
* Assume a situation where we want to model a set of pumps and their runtime
* state in an OPC UA information model. Of course, all pump representations
* should follow the same basic structure, For example, we might have graphical
* representation of pumps in a SCADA visualisation that shall be resuable for
* all pumps.
*
* Following the object-oriented programming paradigm, every pump is represented
* by an object with the following layout:
*
* .. graphviz::
*
* digraph tree {
*
* fixedsize=true;
* node [width=2, height=0, shape=box, fillcolor="#E5E5E5", concentrate=true]
*
* node_root [label=< <I>ObjectNode</I><BR/>Pump >]
*
* { rank=same
* point_1 [shape=point]
* node_1 [label=< <I>VariableNode</I><BR/>ManufacturerName >] }
* node_root -> point_1 [arrowhead=none]
* point_1 -> node_1 [label="hasComponent"]
*
* { rank=same
* point_2 [shape=point]
* node_2 [label=< <I>VariableNode</I><BR/>ModelName >] }
* point_1 -> point_2 [arrowhead=none]
* point_2 -> node_2 [label="hasComponent"]
*
* { rank=same
* point_4 [shape=point]
* node_4 [label=< <I>VariableNode</I><BR/>Status >] }
* point_2 -> point_4 [arrowhead=none]
* point_4 -> node_4 [label="hasComponent"]
*
* { rank=same
* point_5 [shape=point]
* node_5 [label=< <I>VariableNode</I><BR/>MotorRPM >] }
* point_4 -> point_5 [arrowhead=none]
* point_5 -> node_5 [label="hasComponent"]
*
* }
*
* The following code manually defines a pump and its member variables. We omit
* setting constraints on the variable values as this is not the focus of this
* tutorial and was already covered. */
static void
manuallyDefinePump(UA_Server *server) {
UA_NodeId pumpId; /* get the nodeid assigned by the server */
UA_ObjectAttributes oAttr = UA_ObjectAttributes_default;
oAttr.displayName = UA_LOCALIZEDTEXT("en-US", "Pump (Manual)");
UA_Server_addObjectNode(server, UA_NODEID_NULL,
UA_NODEID_NUMERIC(0, UA_NS0ID_OBJECTSFOLDER),
UA_NODEID_NUMERIC(0, UA_NS0ID_ORGANIZES),
UA_QUALIFIEDNAME(1, "Pump (Manual)"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEOBJECTTYPE),
oAttr, NULL, &pumpId);
UA_VariableAttributes mnAttr = UA_VariableAttributes_default;
UA_String manufacturerName = UA_STRING("Pump King Ltd.");
UA_Variant_setScalar(&mnAttr.value, &manufacturerName, &UA_TYPES[UA_TYPES_STRING]);
mnAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ManufacturerName");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ManufacturerName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
mnAttr, NULL, NULL);
UA_VariableAttributes modelAttr = UA_VariableAttributes_default;
UA_String modelName = UA_STRING("Mega Pump 3000");
UA_Variant_setScalar(&modelAttr.value, &modelName, &UA_TYPES[UA_TYPES_STRING]);
modelAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ModelName");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ModelName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
modelAttr, NULL, NULL);
UA_VariableAttributes statusAttr = UA_VariableAttributes_default;
UA_Boolean status = true;
UA_Variant_setScalar(&statusAttr.value, &status, &UA_TYPES[UA_TYPES_BOOLEAN]);
statusAttr.displayName = UA_LOCALIZEDTEXT("en-US", "Status");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "Status"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
statusAttr, NULL, NULL);
UA_VariableAttributes rpmAttr = UA_VariableAttributes_default;
UA_Double rpm = 50.0;
UA_Variant_setScalar(&rpmAttr.value, &rpm, &UA_TYPES[UA_TYPES_DOUBLE]);
rpmAttr.displayName = UA_LOCALIZEDTEXT("en-US", "MotorRPM");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "MotorRPMs"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
rpmAttr, NULL, NULL);
}
/**
* Object types, type hierarchies and instantiation
* ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
* Building up each object manually requires us to write a lot of code.
* Furthermore, there is no way for clients to detect that an object represents
* a pump. (We might use naming conventions or similar to detect pumps. But
* that's not exactly a clean solution.) Furthermore, we might have more devices
* than just pumps. And we require all devices to share some common structure.
* The solution is to define ObjectTypes in a hierarchy with inheritance
* relations.
*
* .. graphviz::
*
* digraph tree {
*
* fixedsize=true;
* node [width=2, height=0, shape=box, fillcolor="#E5E5E5", concentrate=true]
*
* node_root [label=< <I>ObjectTypeNode</I><BR/>Device >]
*
* { rank=same
* point_1 [shape=point]
* node_1 [label=< <I>VariableNode</I><BR/>ManufacturerName<BR/>(mandatory) >] }
* node_root -> point_1 [arrowhead=none]
* point_1 -> node_1 [label="hasComponent"]
*
* { rank=same
* point_2 [shape=point]
* node_2 [label=< <I>VariableNode</I><BR/>ModelName >] }
* point_1 -> point_2 [arrowhead=none]
* point_2 -> node_2 [label="hasComponent"]
*
* { rank=same
* point_3 [shape=point]
* node_3 [label=< <I>ObjectTypeNode</I><BR/>Pump >] }
* point_2 -> point_3 [arrowhead=none]
* point_3 -> node_3 [label="hasSubtype"]
*
* { rank=same
* point_4 [shape=point]
* node_4 [label=< <I>VariableNode</I><BR/>Status<BR/>(mandatory) >] }
* node_3 -> point_4 [arrowhead=none]
* point_4 -> node_4 [label="hasComponent"]
*
* { rank=same
* point_5 [shape=point]
* node_5 [label=< <I>VariableNode</I><BR/>MotorRPM >] }
* point_4 -> point_5 [arrowhead=none]
* point_5 -> node_5 [label="hasComponent"]
*
* }
*
* Children that are marked mandatory are automatically instantiated together
* with the parent object. This is indicated by a `hasModellingRule` reference
* to an object that representes the `mandatory` modelling rule. */
/* predefined identifier for later use */
UA_NodeId pumpTypeId = {1, UA_NODEIDTYPE_NUMERIC, {1001}};
static void
defineObjectTypes(UA_Server *server) {
/* Define the object type for "Device" */
UA_NodeId deviceTypeId; /* get the nodeid assigned by the server */
UA_ObjectTypeAttributes dtAttr = UA_ObjectTypeAttributes_default;
dtAttr.displayName = UA_LOCALIZEDTEXT("en-US", "DeviceType");
UA_Server_addObjectTypeNode(server, UA_NODEID_NULL,
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEOBJECTTYPE),
UA_NODEID_NUMERIC(0, UA_NS0ID_HASSUBTYPE),
UA_QUALIFIEDNAME(1, "DeviceType"), dtAttr,
NULL, &deviceTypeId);
UA_VariableAttributes mnAttr = UA_VariableAttributes_default;
mnAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ManufacturerName");
UA_NodeId manufacturerNameId;
UA_Server_addVariableNode(server, UA_NODEID_NULL, deviceTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ManufacturerName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
mnAttr, NULL, &manufacturerNameId);
/* Make the manufacturer name mandatory */
UA_Server_addReference(server, manufacturerNameId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASMODELLINGRULE),
UA_EXPANDEDNODEID_NUMERIC(0, UA_NS0ID_MODELLINGRULE_MANDATORY), true);
UA_VariableAttributes modelAttr = UA_VariableAttributes_default;
modelAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ModelName");
UA_Server_addVariableNode(server, UA_NODEID_NULL, deviceTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ModelName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
modelAttr, NULL, NULL);
/* Define the object type for "Pump" */
UA_ObjectTypeAttributes ptAttr = UA_ObjectTypeAttributes_default;
ptAttr.displayName = UA_LOCALIZEDTEXT("en-US", "PumpType");
UA_Server_addObjectTypeNode(server, pumpTypeId,
deviceTypeId, UA_NODEID_NUMERIC(0, UA_NS0ID_HASSUBTYPE),
UA_QUALIFIEDNAME(1, "PumpType"), ptAttr,
NULL, NULL);
UA_VariableAttributes statusAttr = UA_VariableAttributes_default;
statusAttr.displayName = UA_LOCALIZEDTEXT("en-US", "Status");
statusAttr.valueRank = UA_VALUERANK_SCALAR;
UA_NodeId statusId;
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "Status"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
statusAttr, NULL, &statusId);
/* Make the status variable mandatory */
UA_Server_addReference(server, statusId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASMODELLINGRULE),
UA_EXPANDEDNODEID_NUMERIC(0, UA_NS0ID_MODELLINGRULE_MANDATORY), true);
UA_VariableAttributes rpmAttr = UA_VariableAttributes_default;
rpmAttr.displayName = UA_LOCALIZEDTEXT("en-US", "MotorRPM");
rpmAttr.valueRank = UA_VALUERANK_SCALAR;
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "MotorRPMs"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
rpmAttr, NULL, NULL);
}
/**
* Now we add the derived ObjectType for the pump that inherits from the device
* object type. The resulting object contains all mandatory child variables.
* These are simply copied over from the object type. The object has a reference
* of type ``hasTypeDefinition`` to the object type, so that clients can detect
* the type-instance relation at runtime.
*/
static void
addPumpObjectInstance(UA_Server *server, char *name) {
UA_ObjectAttributes oAttr = UA_ObjectAttributes_default;
oAttr.displayName = UA_LOCALIZEDTEXT("en-US", name);
UA_Server_addObjectNode(server, UA_NODEID_NULL,
UA_NODEID_NUMERIC(0, UA_NS0ID_OBJECTSFOLDER),
UA_NODEID_NUMERIC(0, UA_NS0ID_ORGANIZES),
UA_QUALIFIEDNAME(1, name),
pumpTypeId, /* this refers to the object type
identifier */
oAttr, NULL, NULL);
}
/**
* Often we want to run a constructor function on a new object. This is
* especially useful when an object is instantiated at runtime (with the
* AddNodes service) and the integration with an underlying process cannot be
* manually defined. In the following constructor example, we simply set the
* pump status to on.
*/
static UA_StatusCode
pumpTypeConstructor(UA_Server *server,
const UA_NodeId *sessionId, void *sessionContext,
const UA_NodeId *typeId, void *typeContext,
const UA_NodeId *nodeId, void **nodeContext) {
UA_LOG_INFO(UA_Log_Stdout, UA_LOGCATEGORY_USERLAND, "New pump created");
/* Find the NodeId of the status child variable */
UA_RelativePathElement rpe;
UA_RelativePathElement_init(&rpe);
rpe.referenceTypeId = UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT);
rpe.isInverse = false;
rpe.includeSubtypes = false;
rpe.targetName = UA_QUALIFIEDNAME(1, "Status");
UA_BrowsePath bp;
UA_BrowsePath_init(&bp);
bp.startingNode = *nodeId;
bp.relativePath.elementsSize = 1;
bp.relativePath.elements = &rpe;
UA_BrowsePathResult bpr =
UA_Server_translateBrowsePathToNodeIds(server, &bp);
if(bpr.statusCode != UA_STATUSCODE_GOOD ||
bpr.targetsSize < 1)
return bpr.statusCode;
/* Set the status value */
UA_Boolean status = true;
UA_Variant value;
UA_Variant_setScalar(&value, &status, &UA_TYPES[UA_TYPES_BOOLEAN]);
UA_Server_writeValue(server, bpr.targets[0].targetId.nodeId, value);
UA_BrowsePathResult_clear(&bpr);
/* At this point we could replace the node context .. */
return UA_STATUSCODE_GOOD;
}
static void
addPumpTypeConstructor(UA_Server *server) {
UA_NodeTypeLifecycle lifecycle;
lifecycle.constructor = pumpTypeConstructor;
lifecycle.destructor = NULL;
UA_Server_setNodeTypeLifecycle(server, pumpTypeId, lifecycle);
}
/** It follows the main server code, making use of the above definitions. */
int main(void) {
UA_Server *server = UA_Server_new();
manuallyDefinePump(server);
defineObjectTypes(server);
addPumpObjectInstance(server, "pump2");
addPumpObjectInstance(server, "pump3");
addPumpTypeConstructor(server);
addPumpObjectInstance(server, "pump4");
addPumpObjectInstance(server, "pump5");
UA_StatusCode retval = UA_Server_runUntilInterrupt(server);
UA_Server_delete(server);