diff --git a/SignalMC/test/step2/AMSB_chargino_step2_Run3_124X_cfg.py b/SignalMC/test/step2/AMSB_chargino_step2_Run3_124X_cfg.py index 2a38c044..cb5edc94 100644 --- a/SignalMC/test/step2/AMSB_chargino_step2_Run3_124X_cfg.py +++ b/SignalMC/test/step2/AMSB_chargino_step2_Run3_124X_cfg.py @@ -2,7 +2,7 @@ # using: # Revision: 1.19 # Source: /local/reps/CMSSW/CMSSW/Configuration/Applications/python/ConfigBuilder.py,v -# with command line options: step1 --filein file:AMSB_chargino_step1.root --fileout file:AMSB_chargino_step2.root --pileup_input dbs:/Neutrino_E-10_gun/Run3Summer21PrePremix-Winter22_122X_mcRun3_2021_realistic_v9-v1/PREMIX --mc --eventcontent PREMIXRAW --datatier GEN-SIM-RAW --conditions auto:phase1_2021_realistic --step DIGI,DATAMIX,L1,DIGI2RAW,HLT:GRun --procModifiers premix_stage2 --nThreads 8 --geometry DB:Extended --datamix PreMix --era Run3 --python_filename step2/AMSB_chargino_124X_step2_Run3_124X_cfg.py --no_exec --customise Configuration/DataProcessing/Utils.addMonitoring -n 10 +# with command line options: step1 --filein file:AMSB_chargino_step1.root --fileout file:AMSB_chargino_step2.root --pileup_input dbs:/Neutrino_E-10_gun/Run3Summer21PrePremix-Winter22_122X_mcRun3_2021_realistic_v9-v1/PREMIX --mc --eventcontent PREMIXRAW --datatier GEN-SIM-RAW --conditions auto:phase1_2021_realistic --step DIGI,DATAMIX,L1,DIGI2RAW,HLT:GRun --procModifiers premix_stage2 --geometry DB:Extended --datamix PreMix --era Run3 --python_filename step2/AMSB_chargino_step2_Run3_124X_cfg.py --no_exec --customise Configuration/DataProcessing/Utils.addMonitoring -n 10 import FWCore.ParameterSet.Config as cms from Configuration.Eras.Era_Run3_cff import Run3 @@ -27,14 +27,14 @@ process.load('Configuration.StandardSequences.FrontierConditions_GlobalTag_cff') process.maxEvents = cms.untracked.PSet( - input = cms.untracked.int32(-1), + input = cms.untracked.int32(10), output = cms.optional.untracked.allowed(cms.int32,cms.PSet) ) # Input source process.source = cms.Source("PoolSource", dropDescendantsOfDroppedBranches = cms.untracked.bool(False), - fileNames = cms.untracked.vstring('file:../step1/pythia8/AMSB_chargino700GeV_ctau1cm_step1.root'), + fileNames = cms.untracked.vstring('file:AMSB_chargino_step1.root'), inputCommands = cms.untracked.vstring( 'keep *', 'drop *_genParticles_*_*', @@ -89,7 +89,7 @@ # Production Info process.configurationMetadata = cms.untracked.PSet( - annotation = cms.untracked.string('step1 nevts:-1'), + annotation = cms.untracked.string('step1 nevts:10'), name = cms.untracked.string('Applications'), version = cms.untracked.string('$Revision: 1.19 $') ) @@ -101,7 +101,7 @@ dataTier = cms.untracked.string('GEN-SIM-RAW'), filterName = cms.untracked.string('') ), - fileName = cms.untracked.string('file:AMSB_chargino700GeV_ctau1cm_step2.root'), + fileName = cms.untracked.string('file:AMSB_chargino_step2.root'), outputCommands = process.PREMIXRAWEventContent.outputCommands, splitLevel = cms.untracked.int32(0) ) @@ -131,10 +131,6 @@ from PhysicsTools.PatAlgos.tools.helpers import associatePatAlgosToolsTask associatePatAlgosToolsTask(process) -#Setup FWK for multithreaded -process.options.numberOfThreads = 8 -process.options.numberOfStreams = 0 - # customisation of the process. # Automatic addition of the customisation function from Configuration.DataProcessing.Utils diff --git a/SignalMC/test/step3/AMSB_chargino_step3_Run3_124X_cfg.py b/SignalMC/test/step3/AMSB_chargino_step3_Run3_124X_cfg.py index 4e1b4ef5..445fa892 100644 --- a/SignalMC/test/step3/AMSB_chargino_step3_Run3_124X_cfg.py +++ b/SignalMC/test/step3/AMSB_chargino_step3_Run3_124X_cfg.py @@ -2,7 +2,7 @@ # using: # Revision: 1.19 # Source: /local/reps/CMSSW/CMSSW/Configuration/Applications/python/ConfigBuilder.py,v -# with command line options: step2 --filein file:AMSB_chargino_step2.root --fileout file:AMSB_chargino_step3.root --mc --eventcontent AODSIM --runUnscheduled --datatier AODSIM --conditions auto:phase1_2021_realistic --step RAW2DIGI,RECO,RECOSIM --nThreads 4 --era Run3 --python_filename step3/AMSB_chargino_step3_Run3_124X_cfg.py --no_exec --customise Configuration/DataProcessing/Utils.addMonitoring -n -1 +# with command line options: step2 --filein file:AMSB_chargino_step2.root --fileout file:AMSB_chargino_step3.root --mc --eventcontent AODSIM --runUnscheduled --datatier AODSIM --conditions auto:phase1_2021_realistic --step RAW2DIGI,RECO,RECOSIM --era Run3 --python_filename step3/AMSB_chargino_step3_Run3_124X_cfg.py --no_exec --customise Configuration/DataProcessing/Utils.addMonitoring -n -1 import FWCore.ParameterSet.Config as cms from Configuration.Eras.Era_Run3_cff import Run3 @@ -30,7 +30,7 @@ # Input source process.source = cms.Source("PoolSource", - fileNames = cms.untracked.vstring('file:../step2/AMSB_chargino700GeV_ctau1cm_step2.root'), + fileNames = cms.untracked.vstring('file:AMSB_chargino_step2.root'), secondaryFileNames = cms.untracked.vstring() ) @@ -81,7 +81,7 @@ filterName = cms.untracked.string('') ), eventAutoFlushCompressedSize = cms.untracked.int32(31457280), - fileName = cms.untracked.string('file:AMSB_chargino700GeV_ctau1cm_step3.root'), + fileName = cms.untracked.string('file:AMSB_chargino_step3.root'), outputCommands = process.AODSIMEventContent.outputCommands ) @@ -103,10 +103,6 @@ from PhysicsTools.PatAlgos.tools.helpers import associatePatAlgosToolsTask associatePatAlgosToolsTask(process) -#Setup FWK for multithreaded -process.options.numberOfThreads = 4 -process.options.numberOfStreams = 0 - # customisation of the process. # Automatic addition of the customisation function from Configuration.DataProcessing.Utils