You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I checked the accuracy of the gated and film with the updated code.
However, each accuracy with mmcosine was about 0.57 on CREMA-D for 200 epochs and a scaling of 2.
(without mmcosine was about 0.60)
Do you have any recommended configurations for them with mmcosine?
In basic_model.py (line34,36), x_film and x_gate should be erased.
The text was updated successfully, but these errors were encountered:
Hi, thanks for your reminder! For FiLM and Gated, the scaling parameter empirically should be much larger, such as 50. Please try it or larger values to find the best result on your device, for we just did coarse search in our experiments.
Thank you for your kind response, Ruize.
I checked the accuracy of the gated and film with the updated code.
However, each accuracy with mmcosine was about 0.57 on CREMA-D for 200 epochs and a scaling of 2.
(without mmcosine was about 0.60)
Do you have any recommended configurations for them with mmcosine?
The text was updated successfully, but these errors were encountered: