% This file runs the optimization procedure.
% Author: VK
% Date : ?
if(SimulSettings.OptMode=="Once")
optimize(sdpv.const,sdpv.J,sdpvarSettings); %This takes time.
sol.sdpv = sdpvar_to_sol(sdpv);
sol.binv = sdpvar_to_sol(binv);
sol.Jstep = value(Jstep);
sol.Jstep = value(Jstep);
sol.Jstep.all = value(Jstep.all);
sol.Jstep.AC_power = value(Jstep.AC_power);
sol.Jstep.Aging = value(Jstep.Aging);
elseif(SimulSettings.OptMode =="Optimizer")
%---------------------------------
nonsvSettings;
% nonsv.initialized=0;
run_observer; % For initialization.
printSettings(SimulSettings)
while(p_loop <= SimulSettings.p_loop_len)
c_kWh_now = c_kWh((p_loop-1)*arbj.Nh_control+(1:arbj.Nh));
nowInput = {c_kWh_now, nonsv.bat.C_nom(nonsv.i), nonsv.bat.Tk(nonsv.i), nonsv.bat.C_batt_for_optimizer};
optResults = sdpv.optimizer( nowInput );
sol = optResults_to_sol(optResults, SimulSettings.optimizerOutputNames);
run_observer;
fprintf('<strong> Loop %d of %d is completed.</strong>\n',p_loop, SimulSettings.p_loop_len);
p_loop = p_loop+1;
tempAllvariables = who;
tempAllvariables_str = string(tempAllvariables);
tempAllvariables(tempAllvariables_str=="sdpv"|tempAllvariables_str=="init"|tempAllvariables_str=="sdpvarSettings"|tempAllvariables_str=="binv"|tempAllvariables_str=="func") = [];
if(mod(p_loop,1)==0)
back_up(SimulSettings.path.checkpoints.current);
pause(0.2);
save(SimulSettings.path.checkpoints.current, tempAllvariables{:});
end
end
tempAllvariables = who;
tempAllvariables_str = string(tempAllvariables);
tempAllvariables(tempAllvariables_str=="sdpv"|tempAllvariables_str=="init"|tempAllvariables_str=="sdpvarSettings"|tempAllvariables_str=="binv"|tempAllvariables_str=="func") = [];
save(SimulSettings.SaveFilePath, tempAllvariables{:});
% figure;
% % plot((0:arbj.dth:(arbj.Nh*arbj.dth))',(optResults{2}-KELVIN));
% % hold on;
% plot((0:nonsv.dth:nonsv.Nh*nonsv.dth)',nonsv.bat.Tk-KELVIN);
% title('Temperature Nonsv');
% % legend('Simul','Nonsv');
%
%
%
%
% figure;
% stairs(nonsv.AC.Pnett);
% hold on;
%
% %
% figure;
% plot(nonsv.bat.dSOHcal); hold on;
% plot(nonsv.bat.dSOHcyc);
% legend('cal','cyc');
% title('aging');
%
% figure;
% plot(nonsv.bat.SOH);
% title('SOH');
% figure;
% plot(nonsv.bat.SOC);
% title('SOC Nonsv');
% hold on;
% plot(nonsv.bat.I_cell/3);
end