Notifications
You must be signed in to change notification settings - Fork 0
/
i2c_master.vhd
247 lines (239 loc) · 14.1 KB
/
i2c_master.vhd
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
--------------------------------------------------------------------------------
--
-- FileName: i2c_master.vhd
-- Dependencies: none
-- Design Software: Quartus II 64-bit Version 13.1 Build 162 SJ Full Version
--
-- HDL CODE IS PROVIDED "AS IS." DIGI-KEY EXPRESSLY DISCLAIMS ANY
-- WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING BUT NOT
-- LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
-- PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL DIGI-KEY
-- BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL
-- DAMAGES, LOST PROFITS OR LOST DATA, HARM TO YOUR EQUIPMENT, COST OF
-- PROCUREMENT OF SUBSTITUTE GOODS, TECHNOLOGY OR SERVICES, ANY CLAIMS
-- BY THIRD PARTIES (INCLUDING BUT NOT LIMITED TO ANY DEFENSE THEREOF),
-- ANY CLAIMS FOR INDEMNITY OR CONTRIBUTION, OR OTHER SIMILAR COSTS.
--
-- Version History
-- Version 1.0 11/01/2012 Scott Larson
-- Initial Public Release
-- Version 2.0 06/20/2014 Scott Larson
-- Added ability to interface with different slaves in the same transaction
-- Corrected ack_error bug where ack_error went 'Z' instead of '1' on error
-- Corrected timing of when ack_error signal clears
-- Version 2.1 10/21/2014 Scott Larson
-- Replaced gated clock with clock enable
-- Adjusted timing of SCL during start and stop conditions
-- Version 2.2 02/05/2015 Scott Larson
-- Corrected small SDA glitch introduced in version 2.1
--
--------------------------------------------------------------------------------
LIBRARY ieee;
USE ieee.std_logic_1164.all;
USE ieee.std_logic_unsigned.all;
ENTITY i2c_master IS
GENERIC(
input_clk : INTEGER := 50_000_000; --input clock speed from user logic in Hz
bus_clk : INTEGER := 400_000); --speed the i2c bus (scl) will run at in Hz
PORT(
clk : IN STD_LOGIC; --system clock
reset_n : IN STD_LOGIC; --active low reset
ena : IN STD_LOGIC; --latch in command
addr : IN STD_LOGIC_VECTOR(6 DOWNTO 0); --address of target slave
rw : IN STD_LOGIC; --'0' is write, '1' is read
data_wr : IN STD_LOGIC_VECTOR(7 DOWNTO 0); --data to write to slave
busy : OUT STD_LOGIC; --indicates transaction in progress
data_rd : OUT STD_LOGIC_VECTOR(7 DOWNTO 0); --data read from slave
ack_error : BUFFER STD_LOGIC; --flag if improper acknowledge from slave
sda : INOUT STD_LOGIC; --serial data output of i2c bus
scl : INOUT STD_LOGIC); --serial clock output of i2c bus
END i2c_master;
ARCHITECTURE logic OF i2c_master IS
CONSTANT divider : INTEGER := (input_clk/bus_clk)/4; --number of clocks in 1/4 cycle of scl
TYPE machine IS(ready, start, command, slv_ack1, wr, rd, slv_ack2, mstr_ack, stop); --needed states
SIGNAL state : machine; --state machine
SIGNAL data_clk : STD_LOGIC; --data clock for sda
SIGNAL data_clk_prev : STD_LOGIC; --data clock during previous system clock
SIGNAL scl_clk : STD_LOGIC; --constantly running internal scl
SIGNAL scl_ena : STD_LOGIC := '0'; --enables internal scl to output
SIGNAL sda_int : STD_LOGIC := '1'; --internal sda
SIGNAL sda_ena_n : STD_LOGIC; --enables internal sda to output
SIGNAL addr_rw : STD_LOGIC_VECTOR(7 DOWNTO 0); --latched in address and read/write
SIGNAL data_tx : STD_LOGIC_VECTOR(7 DOWNTO 0); --latched in data to write to slave
SIGNAL data_rx : STD_LOGIC_VECTOR(7 DOWNTO 0); --data received from slave
SIGNAL bit_cnt : INTEGER RANGE 0 TO 7 := 7; --tracks bit number in transaction
SIGNAL stretch : STD_LOGIC := '0'; --identifies if slave is stretching scl
BEGIN
--generate the timing for the bus clock (scl_clk) and the data clock (data_clk)
PROCESS(clk, reset_n)
VARIABLE count : INTEGER RANGE 0 TO divider*4; --timing for clock generation
BEGIN
IF(reset_n = '0') THEN --reset asserted
stretch <= '0';
count := 0;
ELSIF(clk'EVENT AND clk = '1') THEN
data_clk_prev <= data_clk; --store previous value of data clock
IF(count = divider*4-1) THEN --end of timing cycle
count := 0; --reset timer
ELSIF(stretch = '0') THEN --clock stretching from slave not detected
count := count + 1; --continue clock generation timing
END IF;
CASE count IS
WHEN 0 TO divider-1 => --first 1/4 cycle of clocking
scl_clk <= '0';
data_clk <= '0';
WHEN divider TO divider*2-1 => --second 1/4 cycle of clocking
scl_clk <= '0';
data_clk <= '1';
WHEN divider*2 TO divider*3-1 => --third 1/4 cycle of clocking
scl_clk <= '1'; --release scl
IF(scl = '0') THEN --detect if slave is stretching clock
stretch <= '1';
ELSE
stretch <= '0';
END IF;
data_clk <= '1';
WHEN OTHERS => --last 1/4 cycle of clocking
scl_clk <= '1';
data_clk <= '0';
END CASE;
END IF;
END PROCESS;
--state machine and writing to sda during scl low (data_clk rising edge)
PROCESS(clk, reset_n)
BEGIN
IF(reset_n = '0') THEN --reset asserted
state <= ready; --return to initial state
busy <= '1'; --indicate not available
scl_ena <= '0'; --sets scl high impedance
sda_int <= '1'; --sets sda high impedance
ack_error <= '0'; --clear acknowledge error flag
bit_cnt <= 7; --restarts data bit counter
data_rd <= "00000000"; --clear data read port
ELSIF(clk'EVENT AND clk = '1') THEN
IF(data_clk = '1' AND data_clk_prev = '0') THEN --data clock rising edge
CASE state IS
WHEN ready => --idle state
IF(ena = '1') THEN --transaction requested
busy <= '1'; --flag busy
addr_rw <= addr & rw; --collect requested slave address and command
data_tx <= data_wr; --collect requested data to write
state <= start; --go to start bit
ELSE --remain idle
busy <= '0'; --unflag busy
state <= ready; --remain idle
END IF;
WHEN start => --start bit of transaction
busy <= '1'; --resume busy if continuous mode
sda_int <= addr_rw(bit_cnt); --set first address bit to bus
state <= command; --go to command
WHEN command => --address and command byte of transaction
IF(bit_cnt = 0) THEN --command transmit finished
sda_int <= '1'; --release sda for slave acknowledge
bit_cnt <= 7; --reset bit counter for "byte" states
state <= slv_ack1; --go to slave acknowledge (command)
ELSE --next clock cycle of command state
bit_cnt <= bit_cnt - 1; --keep track of transaction bits
sda_int <= addr_rw(bit_cnt-1); --write address/command bit to bus
state <= command; --continue with command
END IF;
WHEN slv_ack1 => --slave acknowledge bit (command)
IF(addr_rw(0) = '0') THEN --write command
sda_int <= data_tx(bit_cnt); --write first bit of data
state <= wr; --go to write byte
ELSE --read command
sda_int <= '1'; --release sda from incoming data
state <= rd; --go to read byte
END IF;
WHEN wr => --write byte of transaction
busy <= '1'; --resume busy if continuous mode
IF(bit_cnt = 0) THEN --write byte transmit finished
sda_int <= '1'; --release sda for slave acknowledge
bit_cnt <= 7; --reset bit counter for "byte" states
state <= slv_ack2; --go to slave acknowledge (write)
ELSE --next clock cycle of write state
bit_cnt <= bit_cnt - 1; --keep track of transaction bits
sda_int <= data_tx(bit_cnt-1); --write next bit to bus
state <= wr; --continue writing
END IF;
WHEN rd => --read byte of transaction
busy <= '1'; --resume busy if continuous mode
IF(bit_cnt = 0) THEN --read byte receive finished
IF(ena = '1' AND addr_rw = addr & rw) THEN --continuing with another read at same address
sda_int <= '0'; --acknowledge the byte has been received
ELSE --stopping or continuing with a write
sda_int <= '1'; --send a no-acknowledge (before stop or repeated start)
END IF;
bit_cnt <= 7; --reset bit counter for "byte" states
data_rd <= data_rx; --output received data
state <= mstr_ack; --go to master acknowledge
ELSE --next clock cycle of read state
bit_cnt <= bit_cnt - 1; --keep track of transaction bits
state <= rd; --continue reading
END IF;
WHEN slv_ack2 => --slave acknowledge bit (write)
IF(ena = '1') THEN --continue transaction
busy <= '0'; --continue is accepted
addr_rw <= addr & rw; --collect requested slave address and command
data_tx <= data_wr; --collect requested data to write
IF(addr_rw = addr & rw) THEN --continue transaction with another write
sda_int <= data_wr(bit_cnt); --write first bit of data
state <= wr; --go to write byte
ELSE --continue transaction with a read or new slave
state <= start; --go to repeated start
END IF;
ELSE --complete transaction
state <= stop; --go to stop bit
END IF;
WHEN mstr_ack => --master acknowledge bit after a read
IF(ena = '1') THEN --continue transaction
busy <= '0'; --continue is accepted and data received is available on bus
addr_rw <= addr & rw; --collect requested slave address and command
data_tx <= data_wr; --collect requested data to write
IF(addr_rw = addr & rw) THEN --continue transaction with another read
sda_int <= '1'; --release sda from incoming data
state <= rd; --go to read byte
ELSE --continue transaction with a write or new slave
state <= start; --repeated start
END IF;
ELSE --complete transaction
state <= stop; --go to stop bit
END IF;
WHEN stop => --stop bit of transaction
busy <= '0'; --unflag busy
state <= ready; --go to idle state
END CASE;
ELSIF(data_clk = '0' AND data_clk_prev = '1') THEN --data clock falling edge
CASE state IS
WHEN start =>
IF(scl_ena = '0') THEN --starting new transaction
scl_ena <= '1'; --enable scl output
ack_error <= '0'; --reset acknowledge error output
END IF;
WHEN slv_ack1 => --receiving slave acknowledge (command)
IF(sda /= '0' OR ack_error = '1') THEN --no-acknowledge or previous no-acknowledge
ack_error <= '1'; --set error output if no-acknowledge
END IF;
WHEN rd => --receiving slave data
data_rx(bit_cnt) <= sda; --receive current slave data bit
WHEN slv_ack2 => --receiving slave acknowledge (write)
IF(sda /= '0' OR ack_error = '1') THEN --no-acknowledge or previous no-acknowledge
ack_error <= '1'; --set error output if no-acknowledge
END IF;
WHEN stop =>
scl_ena <= '0'; --disable scl
WHEN OTHERS =>
NULL;
END CASE;
END IF;
END IF;
END PROCESS;
--set sda output
WITH state SELECT
sda_ena_n <= data_clk_prev WHEN start, --generate start condition
NOT data_clk_prev WHEN stop, --generate stop condition
sda_int WHEN OTHERS; --set to internal sda signal
--set scl and sda outputs
scl <= '0' WHEN (scl_ena = '1' AND scl_clk = '0') ELSE 'Z';
sda <= '0' WHEN sda_ena_n = '0' ELSE 'Z';
END logic;