You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Description: This is a new setup - my first go with DCC-EX (what a great product!), after years with Digitrax, When I attempt to read a CV from a ESU decoder on the TRK_B, my multi-meter shows about 11vAC, but CV Programmer returns a 'DCC Address Read Failed!' error. I have used to produce the attached log in the hope that you may be able to help. Kind regards, Jeff Law, New Zealand
You will need to do further checking to determine where the issue exists.
Try a different locomotive to determine if it is an issue with the programming track or the locomotive.
There was no evidence that current sense was functioning -- you can briefly short the tracks to see if the short is detected when power is on to the programming track.
<1 PROG>
You can swap the connections and set track A to be the programming track, to see if it is only an issue with track B.
<=A PROG>
You have not provided the startup log. Sometimes the programming track has been disabled -- there is an option to disable the programming track in EX-Installer, or in config.h
Startup log would also show the version and motor shield.
Sent by ([email protected]). Created by fire.
Jeff created a ticket
Name: Jeff Law
Email: [email protected]
Timezone: 12
Software: EX-CommandStation
Version: 4.0.x
Title: CV Programmer will nor read/write CVs
Description: This is a new setup - my first go with DCC-EX (what a great product!), after years with Digitrax, When I attempt to read a CV from a ESU decoder on the TRK_B, my multi-meter shows about 11vAC, but CV Programmer returns a 'DCC Address Read Failed!' error. I have used to produce the attached log in the hope that you may be able to help. Kind regards, Jeff Law, New Zealand
Remaining email Quota: 99
Attachments:
The text was updated successfully, but these errors were encountered: