ADM1266 Margin - Closed Loop.py
131 lines (108 loc) · 6.68 KB
/
ADM1266 Margin - Closed Loop.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
# Copyright (c) 2017-2021 Analog Devices Inc.
# All rights reserved.
# www.analog.com
#
# SPDX-License-Identifier: Apache-2.0
#
# Release Notes -----------------------------------------------------------
# This script uses the Aardvark from Total Phase drivers to communicate with ADM1266.
# If you would like to use other devices, please comment out the Aardvark sections below.
# Open PMBus_I2C.py and replace aardvark_py APIs with the dongle APIs that you are using.
# No other modification is required
import PMBus_I2C
import ADM1266_Lib
import sys
if sys.version_info.major < 3:
input = raw_input
if __name__ == '__main__':
# Open Connection to Aardvark (Comment this section out for using other devices other than Aardvark)
# If no dongle ID is passed into the function an auto scan will be performed and the first dongle found will be used
# For using a specific dongle pass the unique ID number, as shown in example below.
# Example: PMBus_I2C.Open_Aardvark(1845957180)
PMBus_I2C.Open_Aardvark()
# PMBus address of all ADM1266 in this design. e.g: [0x40, 0x42]
ADM1266_Lib.ADM1266_Address = [0x40, 0x42]
# Check if all the devices listed in ADM1266_Lib.ADM1266_Address above is present.
# If all the devices are not present the function will throw an exception and will not procced with the remaining code.
ADM1266_Lib.device_present()
# Margin all or single select
margin_type = input("Enter 'a' to margin all rails, 's' to margin a single rail, 'u' to update margin percentage: ")
margin_type = margin_type.lower()
if ADM1266_Lib.refresh_status() == True:
print("Memory refresh is currently running, please try after 10 seconds.")
else:
if margin_type == 'a':
# The following function margins all the closed loop rails for the devices addresses listed above
# The valid parameters for the first variable are:
# "High" - Margin all rails to high
# "Low" - Margin all rails to low
# "Vout" - Margin all rails Vout
# "Disable" - Disable closed loop margining
# The valid parameter for the secound variable are:
#True - Send margin high as group command. The stop is issued after writing marginging data to all the devices.
# False - Send margin high command indivisually to each device
margin_type = input("Enter margin type (e.g. High, Low, Vout, Disable): ")
group_command = True
ADM1266_Lib.margin_all(margin_type,group_command)
elif margin_type == 's':
# ADM1266_Lib.margin_single(Device address, Physical pin Name to be margined)
ADM1266_Lib.Init_Lists()
ADM1266_Lib.System_Parse()
dac_config_data = ADM1266_Lib.dac_mapping()
index = 0
for num_adm in range(len(dac_config_data)):
address = ADM1266_Lib.ADM1266_Address.index(dac_config_data[index].address)
(value, status, name) = ADM1266_Lib.Get_Rail_Current_Data(address, dac_config_data[index].input_channel)
print(str(index) + ". " + str(name))
index+=1
if len(dac_config_data) != 0:
index = input("Select rail to margin (0-" + str(index-1) + "): ")
index = int(index, 10)
margin_type = input("Enter margin type (e.g. High, Low, Vout, Disable): ")
ADM1266_Lib.margin_single(dac_config_data[index].address, dac_config_data[index].input_channel, margin_type)
else:
print("No rails are margined closed loop.")
#address = input("Enter device address (e.g. 0x40): ")
#channel = input("Enter channel name (e.g. VH1, VP1): ")
#margin_type = input("Enter margin type (e.g. High, Low, Vout, Disable): ")
#ADM1266_Lib.margin_single(address, channel, margin_type)
elif margin_type == 'u':
# The following function updates the margining thresholds for all closed loop margined rail or a single rail
margin_type = input("Enter 'a' to update margin percentage for all rails, 's' to update margin percentage for a single rail: ")
margin_type = margin_type.lower()
dac_config_data = ADM1266_Lib.dac_mapping()
if margin_type == "a":
margin_pct = input("Enter margin percentage:+/- ")
margin_pct = float(margin_pct)
if len(dac_config_data) != 0:
index = 0
for num_adm in range(len(dac_config_data)):
ADM1266_Lib.margin_single_percent(dac_config_data[index].address, dac_config_data[index].input_channel, margin_pct)
index+=1
print("Margining thresholds updated to +/-" + str(margin_pct) + "%.")
else:
print("No rails are margined closed loop.")
elif margin_type == 's':
ADM1266_Lib.Init_Lists()
ADM1266_Lib.System_Parse()
index = 0
for num_adm in range(len(dac_config_data)):
address = ADM1266_Lib.ADM1266_Address.index(dac_config_data[index].address)
(value, status, name) = ADM1266_Lib.Get_Rail_Current_Data(address, dac_config_data[index].input_channel)
print(str(index) + ". " + str(name))
index+=1
if len(dac_config_data) != 0:
index = input("Select a rail index number to update threshold (0-" + str(index-1) + "): ")
index = int(index, 10)
margin_pct = input("Enter margin percentage:+/- ")
margin_pct = float(margin_pct)
ADM1266_Lib.margin_single_percent(dac_config_data[index].address, dac_config_data[index].input_channel, margin_pct)
print("Margining thresholds updated to +/-" + str(margin_pct) + "%.")
else:
print("No rails are margined closed loop.")
else:
print("Select a valid option.")
else:
print("Select a valid option.")
# Close Connection to Aardvark ( Comment this section out for using other devices other than Aardvark)
PMBus_I2C.Close_Aardvark()