The L Message

This message is amongst those sent by the cube on connect. Send an 'l' command to get the cube to send it again.

l:\r\n

The L message looks like this:

L:Cw/a7QkSGBgoAMwACw/DcwkSGBgoAM8ACw/DgAkSGBgoAM4A

The hexdump:

0000000000:  4c 3a 43 77 2f 61 37 51 6b 53 47 42 67 6f 41 4d  :L:Cw/a7QkSGBgoAM
0000000010:  77 41 43 77 2f 44 63 77 6b 53 47 42 67 6f 41 4d  :wACw/DcwkSGBgoAM
0000000020:  38 41 43 77 2f 44 67 41 6b 53 47 42 67 6f 41 4d  :8ACw/DgAkSGBgoAM
0000000030:  34 41 0D 0A                                      :4A..

Like the M message, the main part is base64 encoded. When decoded, it looks like this:

0000000000:  0b 0f da ed 09 12 18 18 28 9d 0b 04 0b 0f c3 73  :................
0000000010:  09 12 18 18 28 00 cf 00 0b 0f c3 80 09 12 18 18  :................
0000000020:  28 00 ce 00                                      :....

This part of the messsage consists of following fields:

Offset  Description         Length      Example Value
==============================================================================
0       Submessage Length   1           6
1-3     RF Address          3           0FDAED
4       Unknown             1           09
5-6     Flags               2           1218

If the submessage length is greater than 6, these fields follow:

Offset  Description         Length      Example Value
==============================================================================
7       Valve Position      1           128
8       Temperature         1           14
9-10    Date Until          2           9D0B - Appears not to apply for heater thermostat
11      Time Until          1           4

The (LSB of byte at offset 9 * 256) plus byte at offset 10 sometimes contains the heater thermostat actual temperature:

9-10     Actual Temperature  2           205

If the submessage length is 12 (for a WallMountedThermostat), the actual temperature is always provided here:

Offset  Description         Length      Example Value
==============================================================================
12      Actual Temperature  1           219

A L message can consist of many submessages, but is always terminated by

0000000020:        ce 00 

Submessage Length

0000000000:  0b

This determines how long the following submessage will be. Eco buttons will have 8 byte long submessages, while valves have 11 byte long submessages. A WallMountedThermostat adds another byte, making a 12 byte message.

RF Address

0000000000:     0f da ed

These 3 bytes are the RF Address of the device

Unknown

0000000000:              09

The meaning of this byte is currently unknown.

Flags

0000000000:                 12 18

These two bytes can be decoded as following:

hex:  |    12     |    18     |
dual: | 0001 0010 | 0001 1000 |
           | |||    |||| | ||
           | |||    |||| | ++--- mode: 00=auto/weekly program
           | |||    |||| |             01=manual
           | |||    |||| |             10=vacation
           | |||    |||| |             11=boost
           | |||    |||| |
           | |||    |||| +------ dst setting: 0=inactive
           | |||    ||||                      1=active
           | |||    ||||
           | |||    |||+-------- gateway: 0=unknown
           | |||    |||                   1=known
           | |||    |||
           | |||    ||+--------- panel: 0=unlocked
           | |||    ||                  1=locked
           | |||    ||
           | |||    |+---------- link status: 0=ok
           | |||    |                         1=error
           | |||    |
           | |||    +----------- battery: 0=ok
           | |||                          1=low
           | |||
           | ||+---------------- status initialized: 0=not initialized
           | ||                                      1=initialized
           | ||
           | |+----------------- answer: 0=this message is an answer to a command
           | |                           1=this message is not an answer to a command
           | |
           | +------------------ error: 0=no
           |                            1=yes
           |
           +-------------------- valid: 0=information is invalid
                                        1=information provided is valid

Valve Position

0000000000:                      18

The valve position indicates the position of the radiator valve. 100 is fully open, 0 is closed. A WallMountedThermostat always returns '4' for this value.

Temperature

0000000000:                          28

The temperature indicates the configured temperature and the mode of a device. It can be decoded as following:

hex:  |    28     |
dual: | 0010 1000 |
        | || ||||
        | ++-++++-- temperature: 10 1000 -> 40 = temp * 2
        |                      (to get the actual temperature, the value must be divided by 2: 40/2 = 20)
        |
        |
        +---------- actual temperature MSB

The mode here is not updated; the mode from the second flag byte is correct though.

Date Until

0000000000:                             9d 0b

Date until indicates to which date the given temperature is set. It does not appear to apply to the radiator thermostat. It can be decoded as following:

           +-++++--------------- day: 1 1101 -> 29
           | ||||  
dual: | 1001 1101 | 0000 1011 | (9D0B)
        |||          | | ||||
        |||          | +-++++--- year: 0 1011 -> 11 = year - 2000
        |||          |                 (to get the actual year, 2000 must be added to the value: 11+2000 = 2011)
        |||          |
        +++----------+---------- month: 1000 -> 8

In this example the temperature is set till Aug 29, 2011.

Time Until

0000000000:                                   04

Time until indicates to which date the given temperature is set. In this example it is set to 2:00 (04 * 0,5 hours = 2:00)

Actual Temperature (HeaterThermostat)

If a HeaterThermostat is in 'auto' mode, the actual temperature is sometimes returned at offset 9-10. This seems to only appear when the valve moves, although changing the set temperature might be enough. In adition, if the HeaterThermostat is in a room that has a linked WallMountedThermostat, this shows the temperature measured by the WallMountedThermostat instead.

9       Actual Temperature  2           205

offset|      9    | ... |      10    |
hex   |     01    |     |     32    |
binary| 0000 0001 | ... | 0011 0010 |
                |         |||| ||||
                +---------++++-++++--- actual temperature (°C*10): 100110010 = 30.6°C

Actual Temperature (WallMountedThermostat)

11      Actual Temperature  1           219

Room temperature measured by the wall mounted thermostat in °C * 10. For example 0xDB = 219 = 21.9°C The temperature is represented by 9 bits; the 9th bit is available as the top bit at offset 8

offset|      8    | ... |     12    |
hex   |     B2    |     |     24    |
binary| 1011 0010 | ... | 0010 0100 |
        | || ||||         |||| ||||
        | ++-++++--------------------- temperature (°C*2):            110010 = 25.0°C
        |                 |||| ||||
        +-----------------++++-++++--- actual temperature (°C*10): 100100100 = 29.2°C

Window switch